Filters · 8 active
Manufacturer:
COLIBRI
Candy
FUJITSU
Inventor
TOSHIBA
Vulcano
WESTPOINT
AIRCLASS
(1)
AIRWELL
(21)
ATLANTIC
(9)
AUX
(35)
BOSCH
(43)
BRYANT
(1)
Buderus
(8)
CARRIER
(44)
CIAT
(11)
CONFORT AIR
(1)
DAIKIN
(170)
DE DIETRICH
(8)
EQUATION
(0)
FUJI ELECTRIC
(38)
Fujitsu Atlantic
(48)
GENERAL
(62)
GREE
(51)
GSS
(1)
HAIER
(142)
HEC
(1)
HEIWA
(3)
HISENSE
(95)
HITACHI
(26)
IVT
(6)
KAYSUN
(10)
LG
(77)
MIDEA
(171)
MITSUBISHI ELECTRIC
(131)
Mitsubishi Heavy Industries
(36)
NORD
(17)
Nobu
(2)
PANASONIC
(94)
PITSOS
(1)
RIELLO
(11)
Rotenso
(0)
SAMSUNG
(46)
THERMOR
(14)
Viessmann
(5)
XTRON
(1)
YORK
(7)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U6RSL(2)-18/LN2UVI-09WFI+LN2UVI-09WFI
ODU + Wall Mounted
|
Inventor | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.71 | -10° | 5.30 | 4.34 | |
|
PFZUVO-12/PFZUVI-12WIFI
Professional Z
|
Inventor | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.20 | 3.00 | |
|
CY-12RAIN-A/CY-12RAOUT-A
Candy Pura 2025
|
Candy | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.20 | 3.00 | |
|
AOYG22KATA/ABYG22KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.35 | -15° | 6.00 | 4.40 | |
|
AOEG22KATA/ABEG22KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.35 | -15° | 6.00 | 4.40 | |
|
AOEG22KATA/ABYG22KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.35 | -15° | 6.00 | 4.40 | |
|
CY-2M14AOUT-A/CY-09QBIN-A/CY-12QBIN-A
Pearl Premium-Multisplit
|
Candy | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.10 | -10° | 4.00 | 3.30 | |
|
CY-2T14AOUT-A/CY-09RAIN-MA/CY-12RAIN-MA
Revive plus-Multisplit
|
Candy | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 3.80 | -10° | 4.00 | 3.30 | |
|
CY-18RBW-IN/CY-18RBW-OUT
CANDY - R-
|
Candy | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 4.90 | 3.60 | |
|
AOYG18KATA/ABYG18KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/ABEG18KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/ABYG18KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
U7RS-18/V7KI-18WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
AOYG14KATA/ARXG14KLLAP
ARXG**K
|
FUJITSU | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOEG14KATA/ARXG14KLLAP
ARXG**K
|
FUJITSU | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
U6RSL(2)-18/AR5VI-09WiFi+AR5VI-09WiFi
ODU + Wall Mounted
|
Inventor | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.30 | 4.30 | |
|
PFZUVO-18/PFZUVI-18WIFI
Professional Z
|
Inventor | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.60 | -10° | 4.80 | 3.60 | |
|
CY-18RAIN-A/CY-18RAOUT-A
Candy Pura 2025
|
Candy | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.71 | -10° | 4.80 | 3.60 | |
|
FUTO-18/FUTI-18WFI
Futura AI
|
Inventor | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.70 | 4.00 | 3.15 | -10° | 5.10 | 3.30 | |
|
RAS-16B2AVG-E2/RAS-B16B2KVG-E2
SEIYA
|
TOSHIBA | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.45 | -15° | 4.20 | 3.30 | |
|
RAS-16B2AVG-E2/RAS-B16B2KV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.45 | -15° | 4.20 | 3.30 | |
|
RAS-16LAV2G-E/RAS-B16LKV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.45 | -15° | 4.20 | 3.30 | |
|
AOYG22KATA/ARXG22KMLA
ARXG**K
|
FUJITSU | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOYG22KATA/ARXG22KMLB
ARXG**K
|
FUJITSU | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOEG22KATA/ARXG22KMLB
ARXG**K
|
FUJITSU | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOYG18KATA/AUXG18KVLA
AUXG**K
|
FUJITSU | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.49 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/AUXG18KVLA
AUXG**K
|
FUJITSU | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.49 | -15° | 5.20 | 3.80 | |
|
AOYG22KATA/AUXG22KVLA
AUXG**K
|
FUJITSU | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOEG22KATA/AUXG22KVLA
AUXG**K
|
FUJITSU | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOYG18KATA/ARXG18KLLAP
ARXG**K
|
FUJITSU | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/ARXG18KLLAP
ARXG**K
|
FUJITSU | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
RAS-18B2AVG-E2/RAS-B18B2KVG-E2
SEIYA
|
TOSHIBA | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.23 | -15° | 5.00 | 3.70 | |
|
RAS-18B2AVG-E2/RAS-B18B2KV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.23 | -15° | 5.00 | 3.70 | |
|
RAS-18LAV2G-E/RAS-B18LKV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.23 | -15° | 5.00 | 3.70 | |
|
RAS-24B2AVG-E2/RAS-B24B2KVG-E2
SEIYA
|
TOSHIBA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 6.50 | 4.40 | |
|
RAS-24B2AVG-E2/RAS-B24B2KV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 6.50 | 4.40 | |
|
RAS-24LAV2G-E/RAS-B24LKV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 6.50 | 4.40 | |
|
UE-E3CM 41/2 / UI-L2CU M 26 + UI-L2CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
U7RS-18/V7LI-18WiFiR
Console R32
|
Inventor | Console | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 | |
|
UE-E3CM 41/2 / UI-E3CU M 26 + UI-E3CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
AOYG14KATA/AUXG14KVLA
AUXG**K
|
FUJITSU | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOEG14KATA/AUXG14KVLA
AUXG**K
|
FUJITSU | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOYG14KBTB/ARXG14KLLAP
ARY**K
|
FUJITSU | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOEG14KBTB/ARXG14KLLAP
ARXG**K
|
FUJITSU | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
U7RS-18/V7CRI-18WiFiR
Cassette R32
|
Inventor | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
AOEG14KATA/ARXH14KMTAP
ARX**K
|
FUJITSU | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOYG14KATA/ARXH14KMTAP
ARX**K
|
FUJITSU | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOEG22KATA/ARXH22KMTAP
ARXH**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.55 | -15° | 6.00 | 4.40 | |
|
AOYG22KATA/ARXH22KMTAP
ARX**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.55 | -15° | 6.00 | 4.40 | |
|
AOEG18KATA/ARXH18KMTAP
ARX**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 |