Filters · 8 active
Manufacturer:
BOSCH
Candy
DAIKIN
EQUATION
Fujitsu Atlantic
LG
WESTPOINT
AIRCLASS
(1)
AIRWELL
(21)
ATLANTIC
(9)
AUX
(35)
BRYANT
(1)
Buderus
(8)
CARRIER
(44)
CIAT
(11)
COLIBRI
(1)
CONFORT AIR
(1)
DE DIETRICH
(8)
FUJI ELECTRIC
(38)
FUJITSU
(102)
GENERAL
(62)
GREE
(51)
GSS
(1)
HAIER
(142)
HEC
(1)
HEIWA
(3)
HISENSE
(95)
HITACHI
(26)
IVT
(6)
Inventor
(27)
KAYSUN
(10)
MIDEA
(171)
MITSUBISHI ELECTRIC
(131)
Mitsubishi Heavy Industries
(36)
NORD
(17)
Nobu
(2)
PANASONIC
(94)
PITSOS
(1)
RIELLO
(11)
Rotenso
(0)
SAMSUNG
(46)
THERMOR
(14)
TOSHIBA
(77)
Viessmann
(5)
Vulcano
(4)
XTRON
(1)
YORK
(7)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
UUB1 U20 / UQ18F NA0
UU
|
LG | Console | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.81 | 3.14 | -10° | 5.00 | 3.80 | |
|
RXM50A9 / FFA50A9
RXM
|
DAIKIN | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.98 | 3.90 | 3.49 | -10° | 5.00 | 3.84 | |
|
CY-12RAIN-A/CY-12RAOUT-A
Candy Pura 2025
|
Candy | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.20 | 3.00 | |
|
AOYG22KATA/ABYG22KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.35 | -15° | 6.00 | 4.40 | |
|
RXM50A8 / FFA50A9
RXM
|
DAIKIN | Cassette | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.86 | 3.36 | -15° | 5.00 | 3.84 | |
|
CY-2M14AOUT-A/CY-09QBIN-A/CY-12QBIN-A
Pearl Premium-Multisplit
|
Candy | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.10 | -10° | 4.00 | 3.30 | |
|
CY-2T14AOUT-A/CY-09RAIN-MA/CY-12RAIN-MA
Revive plus-Multisplit
|
Candy | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 3.80 | -10° | 4.00 | 3.30 | |
|
5MWXM68A9 / FBA35A9 / FBA35A9
5MWXM
|
DAIKIN | Ducted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.80 | 3.29 | -15° | 6.80 | 3.60 | |
|
RXM50A9 / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.92 | 3.86 | 3.35 | -10° | 5.00 | 4.35 | |
|
CY-18RBW-IN/CY-18RBW-OUT
CANDY - R-
|
Candy | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 4.90 | 3.60 | |
|
AOYG18KATA/ABYG18KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
RXM50R / FFA50A9
RXM
|
DAIKIN | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.98 | 3.90 | 3.49 | -15° | 5.00 | 3.84 | |
|
RXM50A / FFA50A9
RXM
|
DAIKIN | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.98 | 3.90 | 3.49 | -15° | 5.00 | 3.84 | |
|
AOYG14KATA/ARXG14KLLAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
WZ18AWN SNU1 / WZ18AWU SUU1
780C
|
LG | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.05 | 4.10 | |
|
WZ18AAN SNU1 / WZ18AAU SUU1
780C
|
LG | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.05 | 4.10 | |
|
UUB1 U20 / UM30F N10
UU
|
LG | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.90 | 3.56 | -10° | 7.50 | 4.30 | |
|
UUB1 U20 / UM30F N11
UU
|
LG | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.90 | 3.56 | -10° | 7.50 | 4.30 | |
|
UUB1 U20 / UM30F NA0
UU
|
LG | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.90 | 3.56 | -10° | 7.50 | 4.30 | |
|
CY-18RAIN-A/CY-18RAOUT-A
Candy Pura 2025
|
Candy | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.71 | -10° | 4.80 | 3.60 | |
|
RXM50A8 / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.84 | 3.82 | 3.23 | -15° | 5.00 | 4.35 | |
|
AOYG22KATA/ARXG22KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOYG22KATA/ARXG22KMLB
ARXG**K
|
Fujitsu Atlantic | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
4MXM68A9 / FBA35A9 / FBA35A9
4MXM
|
DAIKIN | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.26 | 3.81 | 3.24 | -15° | 6.80 | 3.60 | |
|
3MXM68A9 / FBA35A9 / FBA35A9
3MXM
|
DAIKIN | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.42 | 3.81 | 3.24 | -15° | 6.80 | 3.60 | |
|
AOYG18KATA/AUXG18KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.49 | -15° | 5.20 | 3.80 | |
|
AOYG22KATA/AUXG22KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOYG18KATA/ARXG18KLLAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
RXM50R / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.86 | 3.35 | -15° | 5.00 | 4.35 | |
|
RXM50A / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.86 | 3.35 | -15° | 5.00 | 4.35 | |
|
RZAG35B / FFA35A9
RZAG
|
DAIKIN | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.80 | 3.71 | -10° | 3.50 | 4.20 | |
|
UUA1 UL0 / UQ12F NA0
UU
|
LG | Console | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.80 | -10° | 3.50 | 3.00 | |
|
W18TI UEU / W18TI NEU
18TI
|
LG | Wall mounted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -15° | 5.10 | 3.80 | |
|
RXM50A8 / FDXM50F9
RXM
|
DAIKIN | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.89 | 2.99 | -15° | 5.00 | 4.00 | |
|
RZAG50B / FDXM50F9
RZAG
|
DAIKIN | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.40 | -10° | 5.00 | 4.30 | |
|
RZAG50B / FNA50A9
RZAG
|
DAIKIN | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.40 | -10° | 5.00 | 4.30 | |
|
5MWXM68A9 / FTXM42A / FTXM25A
5MWXM
|
DAIKIN | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.77 | 3.85 | 3.24 | -15° | 6.70 | 4.30 | |
|
CL5000M 41/2 E / CL5000iM D 21 E + CL5000iM D 21 E
Climate 5000 M
|
BOSCH | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 4.10 | 3.90 | |
|
RXM50A9 / FDXM50F9
RXM
|
DAIKIN | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 3.93 | 3.10 | -10° | 5.00 | 4.00 | |
|
UUB1 U20 / MJ18PC NSK
UU
|
LG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.40 | -10° | 5.00 | 3.90 | |
|
UUB1 U20 / MJ18PC NSK0
UU
|
LG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.40 | -10° | 5.00 | 3.90 | |
|
CL5000M 41/2 E / CL3000iU W 26 E + CL3000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
CL5000M 41/2 E / CL6001iU W 26 E + CL6001iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 4.18 | -10° | 4.10 | 3.80 | |
|
CL5000L 53 E / CL5000iU CN 50 E
Climate 5000i L
|
BOSCH | Console | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 | |
|
RZAG35B / FDXM35F9
RZAG
|
DAIKIN | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -10° | 3.50 | 3.50 | |
|
RZAG35B / FNA35A9
RZAG
|
DAIKIN | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -10° | 3.50 | 3.50 | |
|
CL5000M 41/2 E / CL5000iU W 26 E + CL5000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
RXM60R / FFA60A9
RXM
|
DAIKIN | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.76 | 4.04 | 3.41 | -15° | 5.70 | 3.96 | |
|
AOYG14KATA/AUXG14KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.52 | -15° | 4.30 | 3.20 | |
|
2MXM68A9 / FTXM42R / FTXM25R
2MXM
|
DAIKIN | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.94 | 3.86 | 3.95 | -15° | 6.70 | 4.30 |