Filters · 4 active
Manufacturer:
LG
SAMSUNG
Vulcano
AIRCLASS
(1)
AIRWELL
(21)
ATLANTIC
(9)
AUX
(21)
BOSCH
(41)
BRYANT
(1)
Buderus
(8)
CARRIER
(42)
CIAT
(11)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(5)
DAIKIN
(170)
EQUATION
(0)
FUJI ELECTRIC
(38)
FUJITSU
(102)
Fujitsu Atlantic
(48)
GENERAL
(62)
GREE
(45)
GSS
(1)
HAIER
(142)
HEC
(1)
HEIWA
(3)
HISENSE
(84)
HITACHI
(26)
IVT
(6)
Inventor
(27)
KAYSUN
(9)
MIDEA
(171)
MITSUBISHI ELECTRIC
(131)
Mitsubishi Heavy Industries
(36)
NORD
(17)
Nobu
(2)
PANASONIC
(94)
RIELLO
(11)
Rotenso
(0)
THERMOR
(14)
TOSHIBA
(77)
Viessmann
(5)
WESTPOINT
(5)
YORK
(7)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
UUB1 U20 / UQ18F NA0
UU
|
LG | Console | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.81 | 3.14 | -10° | 5.00 | 3.80 | |
|
WZ18AWN SNU1 / WZ18AWU SUU1
780C
|
LG | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.05 | 4.10 | |
|
WZ18AAN SNU1 / WZ18AAU SUU1
780C
|
LG | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.05 | 4.10 | |
|
UUB1 U20 / UM30F N10
UU
|
LG | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.90 | 3.56 | -10° | 7.50 | 4.30 | |
|
UUB1 U20 / UM30F N11
UU
|
LG | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.90 | 3.56 | -10° | 7.50 | 4.30 | |
|
UUB1 U20 / UM30F NA0
UU
|
LG | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.90 | 3.56 | -10° | 7.50 | 4.30 | |
|
UUA1 UL0 / UQ12F NA0
UU
|
LG | Console | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.40 | 4.00 | 3.80 | -10° | 3.50 | 3.00 | |
|
AC071RXADKG/AC071RNNDKG
CAC
|
SAMSUNG | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 2.68 | -20° | 6.80 | 4.00 | |
|
W18TI UEU / W18TI NEU
18TI
|
LG | Wall mounted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -15° | 5.10 | 3.80 | |
|
UUB1 U20 / MJ18PC NSK
UU
|
LG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.40 | -10° | 5.00 | 3.90 | |
|
UUB1 U20 / MJ18PC NSK0
UU
|
LG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.40 | -10° | 5.00 | 3.90 | |
|
UE-E3CM 41/2 / UI-L2CU M 26 + UI-L2CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
AR70F18C1DBN/AR70F18C1DBX
RAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 | |
|
AR80F18CAAWN/AR80F18CAAWX
RAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 | |
|
AR80H18CAAWN/AR80H18CAAWX
RAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 | |
|
AR70H18CACBN/AR70H18CACBX
RAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 | |
|
AC071RXADKG/AC071RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 2.62 | -20° | 7.10 | 3.50 | |
|
UE-E3CM 41/2 / UI-E3CU M 26 + UI-E3CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
AC071RXADKG/AC071TNXDKG
CAC
|
SAMSUNG | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.40 | -20° | 7.10 | 3.60 | |
|
UUB1 U20 / CL18F N60
UU
|
LG | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.28 | -10° | 5.00 | 4.10 | |
|
AJ050TXJ2KH / AJ025TNAPKH / AJ025TNAPKH
FJM
|
SAMSUNG | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.01 | 3.68 | -10° | 5.00 | 4.21 | |
|
AR18BXHQASIN / AR18BXHQASIX
RAC
|
SAMSUNG | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -10° | 5.30 | 4.20 | |
|
UE-EC 53 / UI-ECU M 53
Easy 3 Cool
|
Vulcano | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
RM2U15 U18 / RMN09 NSJ / RMN12 NSJ
MU
|
LG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.09 | 4.00 | 4.38 | -10° | 4.10 | 3.60 | |
|
UUB1 U20 / US30F NR0
UU
|
LG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 3.60 | -10° | 7.50 | 4.30 | |
|
AC071RXADKG/AC071BNLDKG
CAC
|
SAMSUNG | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.36 | -20° | 7.10 | 3.70 | |
|
AR40H18C1AMN/AR40H18C1AMX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -15° | 5.28 | 4.16 | |
|
AR40F18C0AMN/AR40F18C0AMX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -15° | 5.28 | 4.16 | |
|
AR40F18C0BMN/AR40F18C0BMX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -15° | 5.28 | 4.16 | |
|
Z2UW18GFA3 / ZMNW09GSJL2 / ZMNW09GSJL2
MU
|
LG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.05 | 3.57 | -10° | 5.20 | 3.70 | |
|
UE-L2C 53 / UI-L2CU M 53
Line cool
|
Vulcano | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
UUB1 U20 / CM24F NA0
UU
|
LG | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.41 | -10° | 6.80 | 4.10 | |
|
UUB1 U20 / CM24F N10
UU
|
LG | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.10 | 3.41 | -10° | 6.80 | 4.10 | |
|
UUB1 U20 / CM24F N11
UU
|
LG | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.10 | 3.41 | -10° | 6.80 | 4.10 | |
|
AR50F18C1AHN/AR50F18C1AHX
RAC
|
SAMSUNG | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR50F18C1BHN/AR50F18C1BHX
RAC
|
SAMSUNG | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
S18EQ UL2 / S18EQ NSK
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.60 | -10° | 5.00 | 3.90 | |
|
S18ET UL2 / S18ET NSK
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.60 | -10° | 5.00 | 3.90 | |
|
DC18RK UL2 / DC18RK NSK
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.60 | -10° | 5.00 | 3.90 | |
|
PC18SK UL2 / PC18SK NSK
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.60 | -10° | 5.00 | 3.90 | |
|
AC18BK UL2 / AC18BK NSK
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.60 | -10° | 5.00 | 3.90 | |
|
AB18BK UL2 / AB18BK NSK
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.60 | -10° | 5.00 | 3.90 | |
|
PC18ST UL2 / PC18ST NSK
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.60 | -10° | 5.00 | 3.90 | |
|
S18ET NSKS/S18ET UL2S
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.60 | -10° | 5.00 | 3.90 | |
|
S18EQ NSKS/S18EQ UL2S
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.60 | -10° | 5.00 | 3.90 | |
|
S18EQ UL2R / S18EQ NSKR
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.60 | -10° | 5.00 | 3.90 | |
|
PC18SQ UL2 / PC18SQ NSK
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.60 | -10° | 5.00 | 3.90 | |
|
H18S1D NS1/H18S1D U18
U18A
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.72 | -10° | 5.00 | 3.90 | |
|
S18EC UL2 / S18EC NSK
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 5.00 | 3.90 | |
|
PC18SC UL2 /PC18SC NSK
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 5.00 | 3.90 |