Filters · 4 active
Manufacturer:
BOSCH
LG
NORD
AIRCLASS
(1)
AIRWELL
(21)
ATLANTIC
(9)
AUX
(21)
BRYANT
(1)
Buderus
(8)
CARRIER
(42)
CIAT
(11)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(5)
DAIKIN
(170)
EQUATION
(0)
FUJI ELECTRIC
(38)
FUJITSU
(102)
Fujitsu Atlantic
(48)
GENERAL
(62)
GREE
(45)
GSS
(1)
HAIER
(142)
HEC
(1)
HEIWA
(3)
HISENSE
(84)
HITACHI
(26)
IVT
(6)
Inventor
(27)
KAYSUN
(9)
MIDEA
(171)
MITSUBISHI ELECTRIC
(131)
Mitsubishi Heavy Industries
(36)
Nobu
(2)
PANASONIC
(94)
RIELLO
(11)
Rotenso
(0)
SAMSUNG
(46)
THERMOR
(14)
TOSHIBA
(77)
Viessmann
(5)
Vulcano
(4)
WESTPOINT
(5)
YORK
(7)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
UUB1 U20 / UQ18F NA0
UU
|
LG | Console | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.81 | 3.14 | -10° | 5.00 | 3.80 | |
|
AS35NYS1-H/1U35NYS1-H
NORD - R plus new
|
NORD | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 2.74 | -10° | 3.50 | 3.00 | |
|
AS35QJIN/US35QJOD
NORD - R ECO MIX
|
NORD | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 2.74 | -10° | 3.50 | 3.00 | |
|
AS50QJIN/US50QJOD
NORD - R ECO MIX
|
NORD | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 4.90 | 3.60 | |
|
AS50NYS1-H/1U50NYS1-H
NORD - R plus new
|
NORD | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 4.90 | 3.60 | |
|
AS50RHE1/US50RHE1
NORD - R ECO
|
NORD | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 4.90 | 3.60 | |
|
WZ18AWN SNU1 / WZ18AWU SUU1
780C
|
LG | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.05 | 4.10 | |
|
WZ18AAN SNU1 / WZ18AAU SUU1
780C
|
LG | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.05 | 4.10 | |
|
AS50QAIN/US50QAOD
NORD - P plus
|
NORD | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.60 | -10° | 5.30 | 4.20 | |
|
UUB1 U20 / UM30F N10
UU
|
LG | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.90 | 3.56 | -10° | 7.50 | 4.30 | |
|
UUB1 U20 / UM30F N11
UU
|
LG | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.90 | 3.56 | -10° | 7.50 | 4.30 | |
|
UUB1 U20 / UM30F NA0
UU
|
LG | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.90 | 3.56 | -10° | 7.50 | 4.30 | |
|
UUA1 UL0 / UQ12F NA0
UU
|
LG | Console | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.40 | 4.00 | 3.80 | -10° | 3.50 | 3.00 | |
|
W18TI UEU / W18TI NEU
18TI
|
LG | Wall mounted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -15° | 5.10 | 3.80 | |
|
CL5000M 41/2 E / CL5000iM D 21 E + CL5000iM D 21 E
Climate 5000 M
|
BOSCH | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 4.10 | 3.90 | |
|
UUB1 U20 / MJ18PC NSK
UU
|
LG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.40 | -10° | 5.00 | 3.90 | |
|
UUB1 U20 / MJ18PC NSK0
UU
|
LG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.40 | -10° | 5.00 | 3.90 | |
|
CL5000M 41/2 E / CL3000iU W 26 E + CL3000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
CL5000M 41/2 E / CL6001iU W 26 E + CL6001iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 4.18 | -10° | 4.10 | 3.80 | |
|
CL5000L 53 E / CL5000iU CN 50 E
Climate 5000i L
|
BOSCH | Console | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 | |
|
CL5000M 41/2 E / CL5000iU W 26 E + CL5000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
AS35QAIN/US35QAOD
NORD - P plus
|
NORD | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 2.74 | -10° | 3.50 | 3.00 | |
|
CL5000L 53 E / CL5000iU 4CC 53 E
Climate 5000i L
|
BOSCH | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
UUB1 U20 / CL18F N60
UU
|
LG | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.28 | -10° | 5.00 | 4.10 | |
|
CL2000 53 E / CL2000U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
CL2001 53 E / CL2001U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
RM2U15 U18 / RMN09 NSJ / RMN12 NSJ
MU
|
LG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.09 | 4.00 | 4.38 | -10° | 4.10 | 3.60 | |
|
UUB1 U20 / US30F NR0
UU
|
LG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 3.60 | -10° | 7.50 | 4.30 | |
|
Z2UW18GFA3 / ZMNW09GSJL2 / ZMNW09GSJL2
MU
|
LG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.05 | 3.57 | -10° | 5.20 | 3.70 | |
|
CL3000i 53 E / CL3000iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
CL3000i 53 E / CL3200iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
UUB1 U20 / CM24F NA0
UU
|
LG | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.41 | -10° | 6.80 | 4.10 | |
|
CL5000L 53 E / CL5000iL CF 53 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
UUB1 U20 / CM24F N10
UU
|
LG | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.10 | 3.41 | -10° | 6.80 | 4.10 | |
|
UUB1 U20 / CM24F N11
UU
|
LG | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.10 | 3.41 | -10° | 6.80 | 4.10 | |
|
CL5001L 53 E / CL5001iU 4CC 53 E
Climate 5001 L
|
BOSCH | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.57 | -10° | 5.30 | 4.20 | |
|
S18EQ UL2 / S18EQ NSK
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.60 | -10° | 5.00 | 3.90 | |
|
S18ET UL2 / S18ET NSK
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.60 | -10° | 5.00 | 3.90 | |
|
DC18RK UL2 / DC18RK NSK
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.60 | -10° | 5.00 | 3.90 | |
|
PC18SK UL2 / PC18SK NSK
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.60 | -10° | 5.00 | 3.90 | |
|
AC18BK UL2 / AC18BK NSK
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.60 | -10° | 5.00 | 3.90 | |
|
AB18BK UL2 / AB18BK NSK
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.60 | -10° | 5.00 | 3.90 | |
|
PC18ST UL2 / PC18ST NSK
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.60 | -10° | 5.00 | 3.90 | |
|
S18ET NSKS/S18ET UL2S
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.60 | -10° | 5.00 | 3.90 | |
|
S18EQ NSKS/S18EQ UL2S
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.60 | -10° | 5.00 | 3.90 | |
|
S18EQ UL2R / S18EQ NSKR
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.60 | -10° | 5.00 | 3.90 | |
|
PC18SQ UL2 / PC18SQ NSK
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.60 | -10° | 5.00 | 3.90 | |
|
H18S1D NS1/H18S1D U18
U18A
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.72 | -10° | 5.00 | 3.90 | |
|
S18EC UL2 / S18EC NSK
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 5.00 | 3.90 | |
|
PC18SC UL2 /PC18SC NSK
UL2
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 5.00 | 3.90 |