Filters · 4 active
Manufacturer:
AUX
BOSCH
THERMOR
AIRCLASS
(1)
AIRWELL
(21)
ATLANTIC
(9)
BRYANT
(1)
Buderus
(8)
CARRIER
(42)
CIAT
(11)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(5)
DAIKIN
(170)
EQUATION
(0)
FUJI ELECTRIC
(38)
FUJITSU
(102)
Fujitsu Atlantic
(48)
GENERAL
(62)
GREE
(45)
GSS
(1)
HAIER
(142)
HEC
(1)
HEIWA
(3)
HISENSE
(84)
HITACHI
(26)
IVT
(6)
Inventor
(27)
KAYSUN
(9)
LG
(75)
MIDEA
(171)
MITSUBISHI ELECTRIC
(131)
Mitsubishi Heavy Industries
(36)
NORD
(17)
Nobu
(2)
PANASONIC
(94)
RIELLO
(11)
Rotenso
(0)
SAMSUNG
(46)
TOSHIBA
(77)
Viessmann
(5)
Vulcano
(4)
WESTPOINT
(5)
YORK
(7)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
IM26-NS + IM26-NS/E3U55LV2-NG-NS
MULTI-NISEKO MURALE
|
THERMOR | Wall mounted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.00 | -10° | 4.60 | 3.80 | |
|
IM26V2-NG + IM26V2-NG/E3U55LV2-NG-NS
MULTI -NAGANO MURALE PURE
|
THERMOR | Wall mounted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.10 | -10° | 4.80 | 4.00 | |
|
NAGANO CASSETTE IK35-F66-NG / E1U35LV2-NG
NAGANO CASSETTE
|
THERMOR | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.71 | -10° | 3.50 | 3.00 | |
|
NAGANO UI CASSETTE 600 x 600 5000W R32 / NAGANO U.E MONO 5200W R32
NAGANO CASSETTE
|
THERMOR | Cassette | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.42 | -10° | 5.00 | 4.00 | |
|
NAGANO U.I 2600W R32+NAGANO U.I 3500W R32/NAGANO U.E BI 4000W R32
NAGANO MURALE
|
THERMOR | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.10 | -10° | 4.00 | 3.30 | |
|
IM26V2-NG + IM35V2-NG/NAGANO U.E BI 4000W R32
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.10 | -10° | 4.00 | 3.30 | |
|
NISEKO MURALE IM42-NS / E1U42L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.60 | -10° | 4.80 | 3.60 | |
|
AL-H18/4DR3HB3(U) / AUCO-H18/4DR3HA2
Console
|
AUX | Console | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.31 | -10° | 4.70 | 3.70 | |
|
RXYL52M-T1B/FDCO52-B
Console
|
AUX | Console | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.31 | -10° | 4.70 | 3.70 | |
|
AM2-H14/4DR3C+AMWM-H07/4R3A(C*)X2
C SERIES
|
AUX | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.91 | -10° | 3.80 | 3.40 | |
|
AM2-H14/4DR3C + AMWM-H07/4R3A(Q*)X2
Q-smart
|
AUX | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.16 | 4.04 | 2.55 | -10° | 4.10 | 3.70 | |
|
AM2-H14/4DR3C + AMWM-H07/4R3B(Q*)X2
Q-smart
|
AUX | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.18 | 4.04 | 3.91 | -10° | 4.10 | 3.70 | |
|
CL5000M 41/2 E / CL5000iM D 21 E + CL5000iM D 21 E
Climate 5000 M
|
BOSCH | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 4.10 | 3.90 | |
|
CL5000M 41/2 E / CL3000iU W 26 E + CL3000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
CL5000M 41/2 E / CL6001iU W 26 E + CL6001iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 4.18 | -10° | 4.10 | 3.80 | |
|
CL5000L 53 E / CL5000iU CN 50 E
Climate 5000i L
|
BOSCH | Console | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 | |
|
AM2-H14/4DR3C + AMWM-H07/4R3A(H*)X2
Halo
|
AUX | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.97 | 4.15 | 4.21 | -10° | 4.10 | 3.70 | |
|
NAGANO UI MURALE 4200W R32 / NAGANO U.E MONO 4200W R32
NAGANO MURALE
|
THERMOR | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.74 | -10° | 4.20 | 3.60 | |
|
NAGANO MURALE PURE IM42V2-NG / E1U42L-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.74 | -10° | 4.20 | 3.60 | |
|
NAGANO MURALE PURE NOIRE IM42V2-NGN / E1U42L-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.74 | -10° | 4.20 | 3.60 | |
|
NAGANO MURALE PURE IM42V3-NG / E1U42L-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.74 | -10° | 4.20 | 3.60 | |
|
NAGANO MURALE PURE NOIRE IM42V3-NGN / E1U42L-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.74 | -10° | 4.20 | 3.60 | |
|
CL5000M 41/2 E / CL5000iU W 26 E + CL5000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
AM2-H18/4DR3C + AMWM-H09/4R3A(H*)X2
Halo
|
AUX | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.13 | 4.03 | 3.72 | -10° | 5.40 | 4.40 | |
|
AM2-H18/4DR3C + AMWM-H09/4R3A(Q*)X2
Q-smart
|
AUX | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.13 | 4.04 | 2.81 | -10° | 5.40 | 4.40 | |
|
AM2-H18/4DR3C + AMWM-H09/4R3A(J*)x2
J-smart
|
AUX | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.15 | 4.04 | 3.72 | -10° | 5.40 | 4.40 | |
|
AM2-H14/4DR3C + AMWM-H07/4R3A(J*)x2
J-smart
|
AUX | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.18 | 4.13 | 3.91 | -10° | 4.10 | 3.70 | |
|
AM2-H14/4DR3C+AMWM-H07/4R3HA(C*)x2
C SERIES
|
AUX | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
AM2-H14/4DR3C+AMWM-H07/4R3C(J*)x2
J-smart
|
AUX | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
AM2-H14/4DR3C+AMWM-H07/4R3HA(M*)x2
M SERIES
|
AUX | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
RXYM42M(2)-T1B+FTXM21CA-Ax2
CA PRO SERIES
|
AUX | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
RXYM42M(2)-T1B+FTXM21CU1-Ax2
CU PRO SERIES
|
AUX | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
CL5000L 53 E / CL5000iU 4CC 53 E
Climate 5000i L
|
BOSCH | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
NAGANO CONSOLE IC42V3-NG / E1U42L-NG
NAGANO CONSOLE
|
THERMOR | Console | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.11 | -10° | 4.20 | 3.20 | |
|
CL2000 53 E / CL2000U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
CL2001 53 E / CL2001U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
CL3000i 53 E / CL3000iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
CL3000i 53 E / CL3200iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
AM2-H18/4DR3D+AMWM-H09/4R3A(C*)x2
C SERIES
|
AUX | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.44 | 4.34 | 3.90 | -10° | 5.00 | 3.80 | |
|
CL5000L 53 E / CL5000iL CF 53 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
CL5001L 53 E / CL5001iU 4CC 53 E
Climate 5001 L
|
BOSCH | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.57 | -10° | 5.30 | 4.20 | |
|
NAGANO GAINABLE BP IG35BP-NG / E1U35LV2-NG
NAGANO GAINABLE BASSE PRESSION
|
THERMOR | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.73 | -10° | 3.50 | 3.00 | |
|
AM2-H18/4DR3D+AMWM-H09/4R3C(J*)x2
J-smart
|
AUX | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.40 | 3.90 | -10° | 5.30 | 4.00 | |
|
AM2-H18/4DR3D+AMWM-H09/4R3HA(M*)x2
M SERIES
|
AUX | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.40 | 3.90 | -10° | 5.30 | 4.00 | |
|
AM2-H18/4DR3D+AMWM-H09/4R3HA(C*)x2
C SERIES
|
AUX | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.40 | 3.90 | -10° | 5.30 | 4.00 | |
|
RXYM52M(2)-T1B+FTXM26CU1-Ax2
CU PRO SERIES
|
AUX | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.40 | 3.90 | -10° | 5.30 | 4.00 | |
|
RXYM52M(2)-T1B+FTXM26CA-Ax2
CA PRO SERIES
|
AUX | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.40 | 3.90 | -10° | 5.30 | 4.00 | |
|
CL6102i 55 HE / CL6102i W 55 HE
Climate 6102i
|
BOSCH | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.10 | 3.40 | -10° | 5.30 | 4.40 | |
|
CL5000L 53 E / CL5000iU D 53 E
Climate 5000i L
|
BOSCH | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
CL4000i 52 E / CL4000iU W 52 E
Climate 4000i
|
BOSCH | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -10° | 5.20 | 3.40 |