Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(10)
BRYANT
(0)
Buderus
(2)
CARRIER
(10)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(1)
Candy
(0)
DAIKIN
(23)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(10)
Fujitsu Atlantic
(2)
GENERAL
(12)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(11)
IVT
(0)
Inventor
(5)
KAYSUN
(0)
LG
(0)
MIDEA
(9)
MITSUBISHI ELECTRIC
(53)
Mitsubishi Heavy Industries
(9)
NORD
(0)
Nobu
(0)
PANASONIC
(35)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(13)
THERMOR
(0)
TOSHIBA
(52)
Viessmann
(0)
Vulcano
(1)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC071RXADKG/AC071RNNDKG
CAC
|
SAMSUNG | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 2.68 | -20° | 6.80 | 4.00 | |
|
PUZ-ZM60VHA2/SLZ-M60FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.10 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/SLZ-M60FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.10 | -20° | 6.10 | 4.40 | |
|
AC071RXADKG/AC071RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 2.62 | -20° | 7.10 | 3.50 | |
|
AC071RXADKG/AC071TNXDKG
CAC
|
SAMSUNG | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.40 | -20° | 7.10 | 3.60 | |
|
RZAG35A / FFA35A9
RZAG
|
DAIKIN | Cassette | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.80 | 3.71 | -20° | 3.50 | 4.20 | |
|
SRC50ZSX-W3/FDUM50VH
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.82 | 3.89 | 3.39 | -20° | 5.00 | 3.70 | |
|
RZAG50A / FDXM50F9
RZAG
|
DAIKIN | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.40 | -20° | 5.00 | 4.30 | |
|
RZAG50A / FNA50A9
RZAG
|
DAIKIN | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.40 | -20° | 5.00 | 4.30 | |
|
RZAG35A / FDXM35F9
RZAG
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -20° | 3.50 | 3.50 | |
|
RZAG35A / FNA35A9
RZAG
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -20° | 3.50 | 3.50 | |
|
AC071RXADKG/AC071BNLDKG
CAC
|
SAMSUNG | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.36 | -20° | 7.10 | 3.70 | |
|
MOX301-18HFN8-QRD0GW/MSAGCU-18HRFNX-QRD0GW
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
CL3000i 53 E / CL3000iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
GFCAGCU-18HRFN8/GFCAGCU-18HRFN8
Extreme save R32
|
CONFORT AIR | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
MOD-18N8D0/MAG1-18N8
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
MOM-18N8D0/MAG2-18N8
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
MOM-18N8D0-1/MAG2-18N8-1
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
UE-L2C 53 / UI-L2CU M 53
Line cool
|
Vulcano | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
AC166i.2-5,3 / AC166i.2-5,3 W
Logacool
|
Buderus | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
Ν2UVO-18/Ν2UVI-18WFI
Neo
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
MOX301-18HFN8-QRD0GW/MSAGCU-18HRFNX-QRD0GW-CARBON
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
X3BP-18N8D0-O/AGF-18NXD1-I
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
N2VOCP-18/Ν2VICP-18WFI
Neo
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
MOX301-18HFN8-QRD0GW-GR/MSAGCU-18HRFNX-QRD0GW-GR
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
MOX301-18HFN8-QRD0GW-Lite/MSAGCU-18HRFNX-QRD0GW-Lite
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
NPVO-18/NPVI-18WFI
Neo Plus
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
N3VO-18/N3VI-18WFI
Neo
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
VERO-18/VERI-18WFI
Vero
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
CL3000i 53 E / CL3200iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
MOX301-18HFN8/LT/MSAGCU2-18HRFNX
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
AC166i.2-5,3 / AC166i.3-5,3 W
Logacool
|
Buderus | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
RAS-5M34G3AVG-E1/RAS-B13G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 4.07 | -20° | 6.00 | 4.19 | |
|
38WH5M100C1A0TEE/40WHHW035D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 4.07 | -20° | 6.00 | 4.19 | |
|
RAS-5M34G3AVG-E1/RAS-B13P2KVSG-E+RAS-B10P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 4.07 | -20° | 6.00 | 4.19 | |
|
RZAG50A / FFA50A9
RZAG
|
DAIKIN | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.01 | 3.10 | -20° | 5.00 | 4.30 | |
|
CU-CZ35WKE / CS-CZ35WKE
2020
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.30 | 4.08 | -25° | 3.50 | 3.60 | |
|
SRC40ZSX-W1/FDUM40VH
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 3.81 | 4.09 | -20° | 4.00 | 3.00 | |
|
SRC50ZSX-W3/FDE50VH
ZSX-W
|
Mitsubishi Heavy Industries | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.07 | 3.70 | -20° | 5.00 | 3.80 | |
|
CU-CZ35ZKE / CS-CZ35ZKE
2023
|
PANASONIC | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 4.12 | -25° | 3.50 | 3.60 | |
|
RAS-35E2AVG-ND/RAS-B35E2KVG-ND
SEIYA
|
TOSHIBA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.50 | 3.89 | -25° | 3.50 | 3.40 | |
|
RAS-35G3AVSG-ND/RAS-B35G3FVG-ND
Console
|
TOSHIBA | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.77 | -25° | 3.50 | 3.60 | |
|
MUFZ-KW35VGHZ2/MFZ-KW35VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.10 | 3.55 | -25° | 3.50 | 3.60 | |
|
PUZ-ZM60VHA2/PKA-M60KAL2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.04 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA2/PKA-M60KA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.04 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/PKA-M60KA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.04 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/PKA-M60KAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.04 | -20° | 6.10 | 4.40 | |
|
AC071RXADKG/AC071RNMDKG
CAC
|
SAMSUNG | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.20 | -20° | 6.80 | 3.70 | |
|
RAS-25G3AVSG-ND/RAS-B25G3FVG-ND
Console
|
TOSHIBA | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.82 | -25° | 2.50 | 3.50 | |
|
MFZ-KW35VG/MUFZ-KW35VGHZ
M series
|
MITSUBISHI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.10 | 4.10 | 3.55 | -25° | 3.50 | 3.60 |