Filters · 2 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(3)
ATLANTIC
(4)
AUX
(0)
BOSCH
(23)
BRYANT
(0)
Buderus
(4)
CARRIER
(7)
CIAT
(1)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(32)
EQUATION
(0)
FUJI ELECTRIC
(6)
FUJITSU
(20)
Fujitsu Atlantic
(7)
GENERAL
(13)
GREE
(16)
GSS
(0)
HAIER
(48)
HEC
(0)
HEIWA
(2)
HISENSE
(14)
HITACHI
(13)
IVT
(5)
Inventor
(6)
KAYSUN
(1)
LG
(12)
MIDEA
(37)
MITSUBISHI ELECTRIC
(36)
Mitsubishi Heavy Industries
(20)
NORD
(7)
Nobu
(0)
PANASONIC
(40)
RIELLO
(1)
Rotenso
(0)
SAMSUNG
(6)
THERMOR
(0)
TOSHIBA
(20)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(5)
YORK
(0)
Mounting:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RM2U15 U18 / RMN09 NSJ / RMN12 NSJ
MU
|
LG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.09 | 4.00 | 4.38 | -10° | 4.10 | 3.60 | |
|
AOYG14KVCA/AGYG14KVCA
AGY**K
|
FUJITSU | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
AOHG14KVCA/AGHG14KVCA
AGH**K
|
GENERAL | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
ROG14KVCA/RGG14KVCA
RG**K
|
FUJI ELECTRIC | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
AOEG14KVCA/AGEG14KVCA
AGE**K
|
FUJITSU | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
AOEG14KVCA/AGYG14KVCA
AGY**K
|
FUJITSU | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
AOYG14KVCA/AGYG14KVCA
AGY**K
|
Fujitsu Atlantic | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
MUFZ-KW35VGHZ2/MFZ-KW35VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.10 | 3.55 | -25° | 3.50 | 3.60 | |
|
CU-2Z35TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 5.00 | -15° | 3.50 | 3.20 | |
|
SCM41ZS-W/SRK20ZS-WF/SRK20ZS-WF
SCM
|
Mitsubishi Heavy Industries | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.40 | 4.50 | 4.41 | -10° | 4.00 | 3.40 | |
|
MFZ-KW35VG/MUFZ-KW35VGHZ
M series
|
MITSUBISHI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.10 | 4.10 | 3.55 | -25° | 3.50 | 3.60 | |
|
AOYG12KVCA/AGYG12KVCA
AGY**K
|
FUJITSU | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.10 | 3.70 | -15° | 3.50 | 3.50 | |
|
AOHG12KVCA/AGHG12KVCA
AGH**K
|
GENERAL | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.10 | 3.70 | -15° | 3.50 | 3.50 | |
|
ROG12KVCA/RGG12KVCA
RG**K
|
FUJI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.10 | 3.70 | -15° | 3.50 | 3.50 | |
|
AOEG12KVCA/AGEG12KVCA
AGE**K
|
FUJITSU | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.10 | 3.70 | -15° | 3.50 | 3.50 | |
|
AOEG12KVCA/AGYG12KVCA
AGY**K
|
FUJITSU | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.10 | 3.70 | -15° | 3.50 | 3.50 | |
|
AOYG12KVCA/AGYG12KVCA
AGY**K
|
Fujitsu Atlantic | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.10 | 3.70 | -15° | 3.50 | 3.50 | |
|
AS25XCHHRA-NR/1U25KEHFRA-NR
Wall mounted - EXPERT Nordic
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.47 | 4.20 | -10° | 2.60 | 3.00 | |
|
AS35XCHHRA-NR/1U35KEHFRA-NR
Wall mounted - EXPERT Nordic
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.20 | -10° | 3.50 | 3.60 | |
|
GWH12YCXD-K6DNA2B
MONOSPLITS
|
GREE | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.40 | 4.00 | -10° | 3.50 | 3.20 | |
|
GWH12YCXD-K6DNA1Z
MONOSPLITS
|
GREE | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.40 | 4.00 | -10° | 3.50 | 3.20 | |
|
CU-2Z41TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 4.84 | -15° | 4.10 | 3.50 | |
|
MXZ-2HA40VF2/MSZ-HR25VF/MSZ-HR25VF
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.12 | 4.30 | 4.73 | -15° | 4.00 | 3.20 | |
|
MXZ-2HA40VF3/MSZ-HR25VF2/MSZ-HR25VF2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.12 | 4.30 | 4.73 | -15° | 4.00 | 3.20 | |
|
CU-2TZ41CBE/CS-MTZ16CKE/CS-TZ25CKEW
2025
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.20 | 4.07 | -15° | 4.10 | 3.50 | |
|
RAM-E40N2HAE / RAK-DJ15QHAE / RAK-DJ25RHAE
RAM-ENHAE
|
HITACHI | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.22 | 4.20 | 3.90 | -15° | 4.00 | 3.67 | |
|
MOX430-18AFN8-QRD0GW/MSAGCU-18HRFNX-QRD0GW
Extreme save R32
|
MIDEA | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -10° | 5.20 | 3.40 | |
|
CL4000i 52 E / CL4000iU W 52 E
Climate 4000i
|
BOSCH | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -10° | 5.20 | 3.40 | |
|
CU-2Z50TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 4.63 | -15° | 5.00 | 4.20 | |
|
GWH12AVCXD-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 3.00 | |
|
MUFZ-KW25VGHZ2/MFZ-KW25VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.30 | 4.10 | 4.09 | -25° | 2.50 | 3.50 | |
|
AS25S2SJ1FA-3/AS25S2SJ1FA-3/2U40S2SM1FA
Super Match Multi
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.30 | |
|
GWH12AUCXD-K6DNA1C
MONOSPLITS
|
GREE | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.51 | 3.20 | |
|
HMIP2-35W-EUV1 / HMEP2-35-EUV1
HYOKO2
|
HEIWA | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.51 | 3.20 | |
|
MOX430-18HFN8-QRD0GW/MSEPCU-18HRFN8-QRD0GW
All easy-R32
|
MIDEA | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
CL6001i 53 E / CL6001iU W 53 E
Climate 6000i
|
BOSCH | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
WIMO-18322.MH/WIM-18322.MH
NEW GENERATION A+++
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
AEP2-18NXD6-O/AEP2-18NXD6-I
All easy-R32
|
MIDEA | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
MOX430-18HFN8(R)/MSEPCU-18HRFN8(R)
All easy-R32
|
MIDEA | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
MOX430-18HFN8/MSEPCU-18HRFN8
All easy-R32
|
MIDEA | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
HDHC-050N-09M25/YDAC-050R-09M25
HDH
|
AIRWELL | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
WITO-18322.MH/WIT-18322.MH
WIT
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
AC176i.3-5,3 / AC176i.3-5,3 W
Logacool
|
Buderus | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
LEUVO-18/LEUVI-18WFI
Leon
|
Inventor | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
LHUVO-18/LHUVI-18WFI
Leon
|
Inventor | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
LEUVOCP-18/LEUVICP-18WFI
Leon
|
Inventor | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
KAE-P 52 DR9/KAY-P 52 DR12
SUITE Prodigy PRO
|
KAYSUN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
MOX4-18HFN8AD/MSEP-18HFN8AD
All easy-R32
|
MIDEA | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
MOX430-18HFN8-QRD0GW-GR/MSEPCU-18HRFN8-QRD0GW-GR
All easy-R32
|
MIDEA | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
AITO-18322.MH/AIT-18322.MH
AIT
|
AIRCLASS | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 |