Filters · 5 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(4)
ATLANTIC
(2)
AUX
(0)
BOSCH
(2)
BRYANT
(0)
Buderus
(0)
CARRIER
(4)
CIAT
(3)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(28)
EQUATION
(0)
FUJI ELECTRIC
(12)
FUJITSU
(27)
Fujitsu Atlantic
(12)
GENERAL
(10)
GREE
(2)
GSS
(0)
HAIER
(19)
HEC
(0)
HEIWA
(0)
HISENSE
(8)
HITACHI
(4)
IVT
(0)
Inventor
(3)
KAYSUN
(2)
LG
(8)
MIDEA
(12)
MITSUBISHI ELECTRIC
(27)
Mitsubishi Heavy Industries
(7)
NORD
(0)
Nobu
(0)
PANASONIC
(10)
RIELLO
(3)
Rotenso
(0)
SAMSUNG
(6)
THERMOR
(2)
TOSHIBA
(3)
Viessmann
(2)
Vulcano
(0)
WESTPOINT
(0)
YORK
(2)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AB35S2SC2FA/1U35S2SM1FA-2
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.71 | -10° | 3.50 | 3.00 | |
|
AB35S2SC1FA/1U35S2SM1FA-2
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.71 | -10° | 3.50 | 3.00 | |
|
NAGANO CASSETTE IK35-F66-NG / E1U35LV2-NG
NAGANO CASSETTE
|
THERMOR | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.71 | -10° | 3.50 | 3.00 | |
|
RXM50A9 / FFA50A9
RXM
|
DAIKIN | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.98 | 3.90 | 3.49 | -10° | 5.00 | 3.84 | |
|
NAGANO UI CASSETTE 600 x 600 5000W R32 / NAGANO U.E MONO 5200W R32
NAGANO CASSETTE
|
THERMOR | Cassette | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.42 | -10° | 5.00 | 4.00 | |
|
AB50S2SC2FA-1/1U50S2SJ2FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.42 | -10° | 5.00 | 4.00 | |
|
AB50S2SC2FA/1U50S2SJ2FA-2
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.42 | -10° | 5.00 | 4.00 | |
|
AIX240HIM8-1/KC220HIM8 *
Cassette
|
RIELLO | Cassette | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 4.02 | -10° | 4.10 | 3.80 | |
|
38QUS014D8S2-1/42QTD007D8S*
Cassette
|
CARRIER | Cassette | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 4.02 | -10° | 4.10 | 3.80 | |
|
38HM14VS8C-1/42HK07VS8C*
Cassette
|
CIAT | Cassette | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 4.02 | -10° | 4.10 | 3.80 | |
|
AOYG22KATA/ABYG22KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.35 | -15° | 6.00 | 4.40 | |
|
ROG22KATA/RYG22KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.35 | -15° | 6.00 | 4.40 | |
|
AOEG22KATA/ABEG22KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.35 | -15° | 6.00 | 4.40 | |
|
AOEG22KATA/ABYG22KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.35 | -15° | 6.00 | 4.40 | |
|
AOYG22KATA/ABYG22KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.35 | -15° | 6.00 | 4.40 | |
|
RXM50A8 / FFA50A9
RXM
|
DAIKIN | Cassette | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.86 | 3.36 | -15° | 5.00 | 3.84 | |
|
RXM50A9 / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.92 | 3.86 | 3.35 | -10° | 5.00 | 4.35 | |
|
AB35S2SA1FA(H)/1U35S2SM1FA-2
R32 Super Match Plus-1-way cassette
|
HAIER | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.80 | 3.72 | -10° | 3.50 | 3.00 | |
|
AOYG18KATA/ABYG18KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
ROG18KATA/RYG18KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/ABEG18KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/ABYG18KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOYG18KATA/ABYG18KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
RXM50R / FFA50A9
RXM
|
DAIKIN | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.98 | 3.90 | 3.49 | -15° | 5.00 | 3.84 | |
|
RXM50A / FFA50A9
RXM
|
DAIKIN | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.98 | 3.90 | 3.49 | -15° | 5.00 | 3.84 | |
|
RXM50A8 / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.84 | 3.82 | 3.23 | -15° | 5.00 | 4.35 | |
|
AB35S2SC2FA(H)/1U35S2SM1FA-2
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.50 | 3.00 | |
|
YDAM-035R-09M25/CDHM-035N-09M22
OASIS
|
AIRWELL | Cassette | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.50 | 3.00 | |
|
AOYG18KATA/AUXG18KVLA
AUXG**K
|
FUJITSU | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.49 | -15° | 5.20 | 3.80 | |
|
ROG18KATA/RCG18KVLA
RCG**K
|
FUJI ELECTRIC | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.49 | -15° | 5.20 | 3.80 | |
|
AOHG18KATA/AUXG18KVLA
AUXG**K
|
GENERAL | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.49 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/AUXG18KVLA
AUXG**K
|
FUJITSU | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.49 | -15° | 5.20 | 3.80 | |
|
AOYG18KATA/AUXG18KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.49 | -15° | 5.20 | 3.80 | |
|
M2OE-18HFN8-Q/MCA3U-09HRFNX(GA)+MCA3U-09HRFNX(GA)
M2OE-18HFN8-Q
|
MIDEA | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.30 | 4.30 | |
|
AOYG22KATA/AUXG22KVLA
AUXG**K
|
FUJITSU | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.50 | -15° | 6.00 | 4.40 | |
|
ROG22KATA/RCG22KVLA
RCG**K
|
FUJI ELECTRIC | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOHG22KATA/AUXG22KVLA
AUXG**K
|
GENERAL | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOEG22KATA/AUXG22KVLA
AUXG**K
|
FUJITSU | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOYG22KATA/AUXG22KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.50 | -15° | 6.00 | 4.40 | |
|
AC071RXADKG/AC071RNNDKG
CAC
|
SAMSUNG | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 2.68 | -20° | 6.80 | 4.00 | |
|
RXM50R / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.86 | 3.35 | -15° | 5.00 | 4.35 | |
|
RXM50A / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.86 | 3.35 | -15° | 5.00 | 4.35 | |
|
AB 018 DB.UI/1U 018 DC.UE
Cassettes
|
ATLANTIC | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.42 | -10° | 5.00 | 4.00 | |
|
RZAG35B / FFA35A9
RZAG
|
DAIKIN | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.80 | 3.71 | -10° | 3.50 | 4.20 | |
|
PUZ-ZM60VHA2/SLZ-M60FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.10 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/SLZ-M60FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.10 | -20° | 6.10 | 4.40 | |
|
AC071RXADKG/AC071RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 2.62 | -20° | 7.10 | 3.50 | |
|
AB35S2SA1FA/1U35S2SM1FA-2
R32 Super Match Plus-1-way cassette
|
HAIER | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.72 | -10° | 3.50 | 3.00 | |
|
RXM60R / FFA60A9
RXM
|
DAIKIN | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.76 | 4.04 | 3.41 | -15° | 5.70 | 3.96 | |
|
AB50S2SA1FA/1U50S2SJ2FA-2
R32 Super Match Plus-1-way cassette
|
HAIER | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.72 | -10° | 5.00 | 4.00 |