Filters · 4 active
Manufacturer:
CARRIER
EQUATION
WESTPOINT
AIRCLASS
(1)
AIRWELL
(23)
ATLANTIC
(9)
AUX
(21)
BOSCH
(24)
BRYANT
(1)
Buderus
(12)
CIAT
(7)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(2)
DAIKIN
(148)
FUJI ELECTRIC
(14)
FUJITSU
(37)
Fujitsu Atlantic
(17)
GENERAL
(18)
GREE
(23)
GSS
(1)
HAIER
(142)
HEC
(0)
HEIWA
(2)
HISENSE
(59)
HITACHI
(39)
IVT
(1)
Inventor
(32)
KAYSUN
(7)
LG
(72)
MIDEA
(157)
MITSUBISHI ELECTRIC
(103)
Mitsubishi Heavy Industries
(33)
NORD
(16)
Nobu
(2)
PANASONIC
(57)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(32)
THERMOR
(15)
TOSHIBA
(47)
Viessmann
(3)
Vulcano
(6)
YORK
(5)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
42QCE021D8S* / 38QCE021D8S*
Wall mounted
|
CARRIER | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.26 | -10° | 6.12 | 4.75 | |
|
42QHA024D8S*/38QHA024D8S*
Wall mounted
|
CARRIER | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
42QHF024D8S*/38QHF024D8S*
Wall mounted
|
CARRIER | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
Virtus-9K+12K-OUT/Virtus-9K-IN-Multi/Virtus-12K-IN-Multi
Super Match Multi
|
EQUATION | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 5.00 | 4.70 | |
|
38QUS018D8S2-2/42QTD009D8S*
Cassette
|
CARRIER | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.79 | -10° | 5.40 | 4.50 | |
|
42QHG022D8S*/38QHG022D8S*
Wall mounted
|
CARRIER | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.00 | 3.74 | -10° | 6.25 | 4.90 | |
|
42QHG024D8S*/38QHG024D8S*
Wall mounted
|
CARRIER | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.41 | -10° | 7.04 | 5.20 | |
|
Virtus-18K-IN/Virtus-18K-OUT
Wall mounted - Tundra Plus
|
EQUATION | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
38QUS018D8S2-2/42QHE09D8SH*
Wall mounted
|
CARRIER | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.56 | 4.00 | 4.29 | -10° | 5.79 | 4.50 | |
|
42QZL024D8S*/38QUS024D8S*
Ceiling suspended
|
CARRIER | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.90 | -10° | 7.20 | 5.50 | |
|
42QSS024D8S*/38QUS024D8S*
Ducted
|
CARRIER | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.14 | -10° | 7.10 | 5.40 | |
|
38WH5M100C1A0TEE/40WHHW046D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 4.14 | -20° | 7.10 | 4.93 | |
|
Virtus-24K-IN/Virtus-24K-OUT
Wall mounted - Tundra Plus
|
EQUATION | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.47 | 3.26 | -10° | 7.00 | 5.60 | |
|
WIZO-24225.MH / WIZ-24225.MH
WIZ 325
|
WESTPOINT | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.90 | -10° | 7.10 | 5.60 | |
|
38WH5M100C1A0TEE/40WHHW046D1A0TEE/40WHHW035D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 4.20 | -20° | 8.10 | 5.49 | |
|
42QZL024D8S*/38QUS024D8SX*
Ceiling suspended
|
CARRIER | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
38WHSM071A1A0TEE/40WHMW071D1A0TEE
40WHM
|
CARRIER | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.33 | -15° | 6.50 | 5.40 | |
|
WIMO-24322.MH/WIM-24322.MH
NEW GENERATION A+++
|
WESTPOINT | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
WITO-24322.MH/WIT-24322.MH
WIT
|
WESTPOINT | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
WIMO-24326.MH / WIM-24326.MH
WIM 326
|
WESTPOINT | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
42QHE24D8SH*/38QHE24D8SH*
Wall mounted
|
CARRIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.20 | 3.74 | -10° | 6.85 | 5.00 | |
|
38QUS018D8S2-2/42QSS009D8S*
Ducted
|
CARRIER | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 4.29 | -10° | 5.80 | 4.60 | |
|
42QCE024D8SH/38QCE024D8SH
Wall mounted
|
CARRIER | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
38WH4M080C1A0TEE/40WHHW046D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.55 | 4.40 | 4.70 | -20° | 7.10 | 5.02 | |
|
38WHSH060A1A0TEE/40WHHW060D1A0TEE
40WHH
|
CARRIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.72 | -15° | 6.10 | 4.70 | |
|
38WHSH060A1A0TEE/40WHHB060D1A0TEE
40WHH
|
CARRIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.72 | -15° | 6.10 | 4.70 | |
|
42QSV024D8S*/38QUS024D8SX*
Ducted
|
CARRIER | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
38WH4M080C1A0TEE/40WHHW046D1A0TEE/40WHHW035D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.74 | 4.50 | 4.74 | -20° | 8.00 | 5.20 | |
|
38WH4M080C1A0TEE/40WHHW046D1A0TEE/40WHHW046D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.74 | 4.50 | 4.74 | -20° | 8.00 | 5.20 | |
|
WIMO-24325.MH / WIM-24325.MH
WIM 325
|
WESTPOINT | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 6.10 | 4.80 | |
|
42QCE021D8SH/38QCE021D8SH
Wall mounted
|
CARRIER | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 6.10 | 4.80 | |
|
38WH3M070C1A0TEE/40WHHW046D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.60 | 4.35 | -20° | 7.00 | 5.20 | |
|
38WH3M070C1A0TEE/40WHHW046D1A0TEE/40WHHW035D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.60 | 4.35 | -20° | 7.00 | 5.20 | |
|
38WH3M070C1A0TEE/40WHHW046D1A0TEE/40WHHW046D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.60 | 4.35 | -20° | 7.00 | 5.20 |