Filters · 3 active
Manufacturer:
HITACHI
Inventor
AIRCLASS
(1)
AIRWELL
(23)
ATLANTIC
(9)
AUX
(21)
BOSCH
(24)
BRYANT
(1)
Buderus
(12)
CARRIER
(26)
CIAT
(7)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(2)
DAIKIN
(148)
EQUATION
(3)
FUJI ELECTRIC
(14)
FUJITSU
(37)
Fujitsu Atlantic
(17)
GENERAL
(18)
GREE
(23)
GSS
(1)
HAIER
(142)
HEC
(0)
HEIWA
(2)
HISENSE
(59)
IVT
(1)
KAYSUN
(7)
LG
(72)
MIDEA
(157)
MITSUBISHI ELECTRIC
(103)
Mitsubishi Heavy Industries
(33)
NORD
(16)
Nobu
(2)
PANASONIC
(57)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(32)
THERMOR
(15)
TOSHIBA
(47)
Viessmann
(3)
Vulcano
(6)
WESTPOINT
(5)
YORK
(5)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U6RSL(3)-27/AR5VI-09WiFi+AR5VI-18WiFi
ODU + Wall Mounted
|
Inventor | Wall mounted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.71 | -10° | 7.80 | 5.60 | |
|
FUTO-24/FUTI-24WFI
Futura AI
|
Inventor | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.13 | -10° | 6.50 | 4.60 | |
|
O3MVO32-24B/O3MVI32-24WiFiR
Omnia 3 (ECO)
|
Inventor | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
L6VO32-24/L6VI32-24WF
Life PRO
|
Inventor | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
RPIL-2.0UNE1NH / RAS-2.0UNESNH1
Primairy R410 series
|
HITACHI | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.40 | -15° | 5.28 | 4.80 | |
|
AR5VO-24/AR5VI-24WFI
Aria (AR5)
|
Inventor | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.40 | -10° | 7.00 | 4.91 | |
|
PFZUVO-24/PFZUVI-24WIFI
Professional Z
|
Inventor | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.61 | -10° | 6.20 | 4.60 | |
|
RAC-DJ70WHAE / RAK-DJ70RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.10 | -15° | 7.10 | 5.40 | |
|
RAS-2HVRC3 / RPK-2.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.77 | 3.88 | 3.91 | -25° | 5.00 | 5.00 | |
|
Ν2UVO-24/Ν2UVI-24WFI
Neo
|
Inventor | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
N2VOCP-24/Ν2VICP-24WFI
Neo
|
Inventor | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
NPVO-24/NPVI-24WFI
Neo Plus
|
Inventor | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
N3VO-24/N3VI-24WFI
Neo
|
Inventor | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
VERO-24/VERI-24WFI
Vero
|
Inventor | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
U6RSL(3)-21/LV6iCI-09WiFiR+LV6iCI-12WiFiR
ODU + Cassette
|
Inventor | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.71 | -10° | 6.10 | 5.10 | |
|
NRO-24/NRI-24WFI
Nura
|
Inventor | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.41 | -10° | 7.00 | 4.80 | |
|
U7RS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
MFVO32-24/MFVI32-24WFI
Comfort
|
Inventor | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.71 | -10° | 7.00 | 5.60 | |
|
RAS-2HVRC3 / RCIM-2.0FSRE
UTOPIA PRIME
|
HITACHI | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.57 | 3.81 | 3.85 | -25° | 5.00 | 5.00 | |
|
U7RS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
RAS-2.5HVRC3 / RPK-2.5FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.04 | 3.94 | 3.71 | -25° | 5.60 | 5.20 | |
|
RAS-3HVRC3 / RPK-3.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.11 | 3.90 | 3.19 | -25° | 7.10 | 5.60 | |
|
RAC-VJ70NHAE / RAD-VJ70RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.02 | 3.64 | -10° | 7.00 | 5.30 | |
|
U7RS-24/V7DI-24WiFiR
Ducted R32
|
Inventor | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
RAS-2.5HVRC3 / RCIM-2.5FSRE
UTOPIA PRIME
|
HITACHI | Cassette | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.82 | 3.86 | 3.71 | -25° | 5.60 | 5.20 | |
|
RAC-DJ60WHAE / RAK-DJ60RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.50 | -15° | 6.00 | 4.80 | |
|
RAC-VJ60NHAE / RAI-VJ60RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.21 | 3.75 | -10° | 6.00 | 4.70 | |
|
RAC-VJ60NHAE / RAD-VJ60RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.02 | 3.80 | -10° | 6.00 | 4.60 | |
|
RAS-2HVRC3 / RPI-2.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.78 | 3.83 | 4.05 | -25° | 5.00 | 5.00 | |
|
V7FSO-24/V7FSI-24
Floor Standing Cabinet R32
|
Inventor | Floor standing | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.00 | 3.70 | -10° | 7.20 | 5.50 | |
|
U7iRS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
RAC-60NPE / RAD-60RPE
RAC-NPE(D)
|
HITACHI | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.21 | 4.01 | 3.80 | -15° | 6.00 | 4.60 | |
|
RAC-50NPE / RAD-50RPE
RAC-NPE(D)
|
HITACHI | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.01 | 3.82 | -15° | 5.00 | 4.60 | |
|
RAC-70NPD / RAD-70PPD
RAC-NPE(D)
|
HITACHI | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.09 | 3.64 | -15° | 7.00 | 5.20 | |
|
LEUVO-24/LEUVI-24WFI
Leon
|
Inventor | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
LHUVO-24/LHUVI-24WFI
Leon
|
Inventor | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
LEUVOCP -24/LEUVICP-24WFI
Leon
|
Inventor | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
RAS-2.5HVRC3 / RPI-2.5FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 3.92 | 3.80 | -25° | 5.60 | 5.20 | |
|
RAS-2HVRC3 / RPC-2.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.00 | 4.09 | -25° | 5.00 | 5.00 | |
|
RAS-2HVRC3 / RCI-2.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.08 | 4.23 | -25° | 5.00 | 5.00 | |
|
RAC-60NPE / RAI-60RPE
RAC-NPE(D)
|
HITACHI | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.77 | 4.27 | 3.80 | -15° | 6.00 | 4.70 | |
|
U7iRS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
RAM-E53N2HAE / RAK-DJ18RHAE / RAK-DJ35RHAE
RAM-ENHAE
|
HITACHI | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.21 | 3.90 | -15° | 5.30 | 4.80 | |
|
RAM-E53N3HAE / RAK-DJ18RHAE / RAK-DJ35RHAE
RAM-ENHAE
|
HITACHI | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.21 | 3.90 | -15° | 5.30 | 4.80 | |
|
MFVO32-18/MFVI32-18WFI
Comfort
|
Inventor | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 4.00 | -10° | 5.20 | 4.60 | |
|
RAC-60NPE / RAK-60RPE
RAC-NPE(D)
|
HITACHI | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.44 | 4.61 | 3.80 | -15° | 6.00 | 4.70 | |
|
RAC-VJ70WHAE / RAK-VJ70RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 7.00 | 5.40 | |
|
RAS-2.5HVRC3 / RPC-2.5FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.13 | 4.05 | 3.72 | -25° | 5.60 | 5.20 | |
|
RAC-VJ60WHAE / RAK-V60RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 3.80 | -15° | 6.00 | 4.80 | |
|
RAM-Y70N4HAE / RAK-XJ35RHBE / RAK-XJ35RHBE
RAM-YNHAE
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.20 | -10° | 7.00 | 5.90 |