Filters · 4 active
Manufacturer:
FUJI ELECTRIC
Inventor
WESTPOINT
AIRCLASS
(1)
AIRWELL
(23)
ATLANTIC
(9)
AUX
(21)
BOSCH
(24)
BRYANT
(1)
Buderus
(12)
CARRIER
(26)
CIAT
(7)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(2)
DAIKIN
(148)
EQUATION
(3)
FUJITSU
(37)
Fujitsu Atlantic
(17)
GENERAL
(18)
GREE
(23)
GSS
(1)
HAIER
(142)
HEC
(0)
HEIWA
(2)
HISENSE
(59)
HITACHI
(39)
IVT
(1)
KAYSUN
(7)
LG
(72)
MIDEA
(157)
MITSUBISHI ELECTRIC
(103)
Mitsubishi Heavy Industries
(33)
NORD
(16)
Nobu
(2)
PANASONIC
(57)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(32)
THERMOR
(15)
TOSHIBA
(47)
Viessmann
(3)
Vulcano
(6)
YORK
(5)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U6RSL(3)-27/AR5VI-09WiFi+AR5VI-18WiFi
ODU + Wall Mounted
|
Inventor | Wall mounted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.71 | -10° | 7.80 | 5.60 | |
|
ROG24KATA/RCG24KVLA
RCG**K
|
FUJI ELECTRIC | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.80 | 3.61 | -15° | 6.80 | 5.40 | |
|
FUTO-24/FUTI-24WFI
Futura AI
|
Inventor | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.13 | -10° | 6.50 | 4.60 | |
|
O3MVO32-24B/O3MVI32-24WiFiR
Omnia 3 (ECO)
|
Inventor | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
L6VO32-24/L6VI32-24WF
Life PRO
|
Inventor | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
AR5VO-24/AR5VI-24WFI
Aria (AR5)
|
Inventor | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.40 | -10° | 7.00 | 4.91 | |
|
PFZUVO-24/PFZUVI-24WIFI
Professional Z
|
Inventor | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.61 | -10° | 6.20 | 4.60 | |
|
ROG24KATA/RCG24KRLB
RCG**K
|
FUJI ELECTRIC | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.81 | -15° | 6.80 | 5.40 | |
|
ROG24KATA/RYG24KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
ROG24KATA/RDG24KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
Ν2UVO-24/Ν2UVI-24WFI
Neo
|
Inventor | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
N2VOCP-24/Ν2VICP-24WFI
Neo
|
Inventor | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
NPVO-24/NPVI-24WFI
Neo Plus
|
Inventor | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
N3VO-24/N3VI-24WFI
Neo
|
Inventor | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
VERO-24/VERI-24WFI
Vero
|
Inventor | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
U6RSL(3)-21/LV6iCI-09WiFiR+LV6iCI-12WiFiR
ODU + Cassette
|
Inventor | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.71 | -10° | 6.10 | 5.10 | |
|
NRO-24/NRI-24WFI
Nura
|
Inventor | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.41 | -10° | 7.00 | 4.80 | |
|
U7RS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
MFVO32-24/MFVI32-24WFI
Comfort
|
Inventor | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.71 | -10° | 7.00 | 5.60 | |
|
U7RS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
ROG24KBTA3/RSG12KMCC/RSG12KMCC
RO**K Multi
|
FUJI ELECTRIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.83 | -15° | 6.80 | 5.80 | |
|
ROG22KBTB/RYG22KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
U7RS-24/V7DI-24WiFiR
Ducted R32
|
Inventor | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
ROG18KBTA3/RSG07KMCC/RSG12KMCC
RO**K Multi
|
FUJI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
WIZO-24225.MH / WIZ-24225.MH
WIZ 325
|
WESTPOINT | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.90 | -10° | 7.10 | 5.60 | |
|
V7FSO-24/V7FSI-24
Floor Standing Cabinet R32
|
Inventor | Floor standing | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.00 | 3.70 | -10° | 7.20 | 5.50 | |
|
U7iRS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
ROG22KBTB/RDG22KMLB
RD**K
|
FUJI ELECTRIC | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.74 | -15° | 6.00 | 4.80 | |
|
ROG18KLTA/RSG18KLCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
ROG18KLCA/RSG18KLCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
WIMO-24322.MH/WIM-24322.MH
NEW GENERATION A+++
|
WESTPOINT | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
WITO-24322.MH/WIT-24322.MH
WIT
|
WESTPOINT | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
LEUVO-24/LEUVI-24WFI
Leon
|
Inventor | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
LHUVO-24/LHUVI-24WFI
Leon
|
Inventor | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
LEUVOCP -24/LEUVICP-24WFI
Leon
|
Inventor | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
WIMO-24326.MH / WIM-24326.MH
WIM 326
|
WESTPOINT | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
U7iRS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
MFVO32-18/MFVI32-18WFI
Comfort
|
Inventor | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 4.00 | -10° | 5.20 | 4.60 | |
|
ROG22KBTB/RCG22KVLA
RC**K
|
FUJI ELECTRIC | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.74 | -15° | 6.00 | 4.80 | |
|
U7iRS-24/V7iDI-24WiFiR
Ducted R32
|
Inventor | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
WIMO-24325.MH / WIM-24325.MH
WIM 325
|
WESTPOINT | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 6.10 | 4.80 | |
|
INVO-24/INVI-24WFI
Intellia
|
Inventor | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 6.10 | 4.80 | |
|
EMPVO-18/EMPVI-18WFI
Emperor
|
Inventor | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 5.20 | 4.60 | |
|
EMPVO(W)-18/EMPVI(W)-18WFI
Emperor
|
Inventor | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 5.20 | 4.60 | |
|
ROG18KMTA/RSG18KMTE
RS**K
|
FUJI ELECTRIC | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.77 | 4.60 | 4.04 | -15° | 5.20 | 4.80 | |
|
EQO-24/EQI-24WFI
Econ IQ
|
Inventor | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 7.00 | 5.10 | |
|
INVBO-24/INVBI-24WFI
Intellia
|
Inventor | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 7.00 | 5.10 | |
|
ROG22KBTB/RDG22KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.87 | -15° | 6.00 | 4.80 | |
|
EMPVO-24/EMPVI-24WFI
Emperor
|
Inventor | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.10 | 5.60 | |
|
EMPVO(W)-24/EMPVI(W)-24WFI
Emperor
|
Inventor | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.10 | 5.60 |