Filters · 7 active
Manufacturer:
ATLANTIC
BOSCH
COLIBRI
Fujitsu Atlantic
GSS
LG
AIRCLASS
(1)
AIRWELL
(23)
AUX
(46)
BRYANT
(1)
Buderus
(12)
CARRIER
(28)
CIAT
(7)
CONFORT AIR
(1)
Candy
(2)
DAIKIN
(148)
DE DIETRICH
(3)
EQUATION
(3)
FUJI ELECTRIC
(14)
FUJITSU
(37)
GENERAL
(18)
GREE
(27)
HAIER
(141)
HEC
(0)
HEIWA
(2)
HISENSE
(94)
HITACHI
(39)
IVT
(1)
Inventor
(32)
KAYSUN
(8)
MIDEA
(158)
MITSUBISHI ELECTRIC
(103)
Mitsubishi Heavy Industries
(33)
NORD
(16)
Nobu
(2)
PANASONIC
(57)
PITSOS
(1)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(32)
THERMOR
(15)
TOSHIBA
(47)
Viessmann
(3)
Vulcano
(6)
WESTPOINT
(6)
XTRON
(1)
YORK
(5)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
3U 024 NBB.UE/AS 012 JDB.UI+AS 012 JDB.UI
Jade-Multisplit
|
ATLANTIC | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.00 | -10° | 6.40 | 5.00 | |
|
AOYG24KATA/AUXG24KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.80 | 3.61 | -15° | 6.80 | 5.40 | |
|
AB 024 DB.UI/1U 024 DC.UE
Cassette 620 -Monosplit
|
ATLANTIC | Cassette | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.41 | 4.00 | 3.26 | -10° | 7.10 | 5.00 | |
|
CL5000M 53/2 E / CL3000iU W 26 E + CL3000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
AS 018 DBB.UI/ 1U 018 DBRB.UE
Dojo
|
ATLANTIC | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.00 | 4.60 | |
|
CL2000 70 E / CL2000U W 70 E
Climate 2000
|
BOSCH | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
CL2001 70 E / CL2001U W 70 E
Climate 2000
|
BOSCH | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
CL5000M 79/3 E / CL3000iU W 26 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.80 | 5.50 | |
|
MU4R25 U22 / MJ07PC NSJ / MJ18PC NSK
MU
|
LG | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.81 | 3.87 | -15° | 6.40 | 5.10 | |
|
UUC1 U40 / MJ24PC NSK
UU
|
LG | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.70 | 3.90 | 3.00 | -10° | 6.80 | 5.00 | |
|
UUC1 U40 / MJ24PC NSK0
UU
|
LG | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.70 | 3.90 | 3.00 | -10° | 6.80 | 5.00 | |
|
CL5000M 62/3 E / CL3000iU W 26 E + CL3000iU W 35 E
Climate 5000 M
|
BOSCH | Wall mounted | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 6.10 | 5.70 | |
|
COLI24R8SHF/COLI24R8SHC
Wall mounted
|
COLIBRI | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
CL5000M 53/2 E / CL5000iU W 26 E + CL5000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
CL5000M 53/2 E / CL6001iU W 26 E + CL6001iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
CL5000M 53/2 E / CL5000iM D 26 E + CL5000iM D 26 E
Climate 5000 M
|
BOSCH | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.30 | 4.60 | |
|
UUC1 U40 / UM30F NA0
U4
|
LG | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.71 | -10° | 7.50 | 5.40 | |
|
GSX-IDU-024/GSX-ODU-024
GSX
|
GSS | Wall mounted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 6.95 | 5.20 | |
|
AC 024 DB.UI/1U 024 DC.UE
Ceiling floor- Monosplit
|
ATLANTIC | Ceiling suspended | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.41 | 4.00 | 3.26 | -10° | 7.10 | 5.00 | |
|
CL5000L 70 E / CL5000iL CF 70 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
WZ24AWN SNU1 / WZ24AWU SUU1
845D
|
LG | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 6.95 | 5.20 | |
|
WZ24AAN SNU1 / WZ24AAU SUU1
845D
|
LG | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 6.95 | 5.20 | |
|
AOYG24KATA/AUXG24KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.81 | -15° | 6.80 | 5.40 | |
|
AOYG24KATA/ABYG24KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOYG24KATA/ARXG24KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
UUC1 U40 / CM24F NA0
U4
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.31 | -10° | 6.80 | 5.40 | |
|
UUC1 U40 / UM36F N20
U4
|
LG | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.57 | -10° | 9.50 | 5.50 | |
|
UUC1 U40 / UM36F N21
U4
|
LG | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.57 | -10° | 9.50 | 5.50 | |
|
AOYG24KATA/ARXH24KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.81 | -15° | 6.80 | 5.40 | |
|
W24TI UEU / W24TI NEU
24TI
|
LG | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -15° | 7.00 | 5.20 | |
|
CL3000i 70 E / CL3000iU W 70 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
CL3000i 70 E / CL3200iU W 70 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
ASO24DW31/ASI24DW31
Series 4
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
ASO24AW31/ASI24AW31
Series 6
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
CL5000M 53/2 E / CL5000iM CN 26E + CL5000iM CN 26E
Climate 5000 M
|
BOSCH | Console | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
UUC1 U40 / CL24F N30
U4
|
LG | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 3.90 | 3.52 | -10° | 6.80 | 5.40 | |
|
AS 018 JDB.UI/ 1U 018 JDB.UE
Kazendo
|
ATLANTIC | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
UI 5,3 kW MURAO SMART BLANC & UE MONO 5,3 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 3.80 | 4.00 | -10° | 5.30 | 4.60 | |
|
UUC1 U40 / UM30F N10
U4
|
LG | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -10° | 7.80 | 5.40 | |
|
UUC1 U40 / UM30F N11
U4
|
LG | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -10° | 7.80 | 5.40 | |
|
UUC1 U40 / US36F NR0
U4
|
LG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 9.50 | 5.80 | |
|
AOYG24KBTA3/ASYG12KMCC/ASYG12KMCC
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.83 | -15° | 6.80 | 5.80 | |
|
AOYG22KBTB/ABYG22KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
CL5000L 70 E / CL5000iU D 70 E
Climate 5000i U
|
BOSCH | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
MU4R27 U24A0 / MJ09PC NSJ0 / MJ18PC NSK0
MU
|
LG | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.84 | 4.19 | 3.50 | -10° | 7.00 | 5.50 | |
|
S24EC U24 / S24EC NSK
U24A
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
PC24SC U24 / PC24SC NSK
U24A
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
UUC1 U40 / CM24F N10
U4
|
LG | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 3.90 | 3.31 | -10° | 6.80 | 5.40 | |
|
UUC1 U40TK / ZBNW24GM1A1
U4
|
LG | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 3.90 | 3.31 | -10° | 6.80 | 5.40 | |
|
UUC1 U40 / CM24F N11
U4
|
LG | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 3.90 | 3.31 | -10° | 6.80 | 5.40 |