Filters · 3 active
Manufacturer:
CARRIER
MITSUBISHI ELECTRIC
AIRCLASS
(1)
AIRWELL
(23)
ATLANTIC
(9)
AUX
(21)
BOSCH
(24)
BRYANT
(1)
Buderus
(12)
CIAT
(7)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(2)
DAIKIN
(148)
EQUATION
(3)
FUJI ELECTRIC
(14)
FUJITSU
(37)
Fujitsu Atlantic
(17)
GENERAL
(18)
GREE
(23)
GSS
(1)
HAIER
(142)
HEC
(0)
HEIWA
(2)
HISENSE
(59)
HITACHI
(39)
IVT
(1)
Inventor
(32)
KAYSUN
(7)
LG
(72)
MIDEA
(157)
Mitsubishi Heavy Industries
(33)
NORD
(16)
Nobu
(2)
PANASONIC
(57)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(32)
THERMOR
(15)
TOSHIBA
(47)
Viessmann
(3)
Vulcano
(6)
WESTPOINT
(5)
YORK
(5)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MXZ-3E54VA/MSZ-EF18VE3W(B)(S)/MSZ-EF35VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.54 | -15° | 5.30 | 4.80 | |
|
MXZ-4E72VA/MSZ-EF22VE3W(B)(S)/MSZ-EF50VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.70 | 3.80 | 3.11 | -15° | 6.40 | 5.50 | |
|
MXZ-3E68VA/MSZ-EF18VE3W(B)(S)/MSZ-EF50VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.50 | 3.80 | 2.97 | -15° | 6.20 | 5.10 | |
|
MXZ-4E83VA/MSZ-EF42VE3W(B)(S)/MSZ-EF42VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 2.97 | -15° | 7.00 | 5.90 | |
|
SUZ-SM71VA/PLA-SM71EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.00 | 3.90 | 3.50 | -10° | 7.10 | 5.80 | |
|
SUZ-SM71VA2/PLA-SM71EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.00 | 3.90 | 3.50 | -10° | 7.10 | 5.80 | |
|
MSZ-HJ71VA/MUZ-HJ71VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 4.00 | 3.32 | -10° | 7.10 | 5.40 | |
|
SUZ-M71VA/SEZ-M71DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.50 | 3.90 | 3.50 | -10° | 7.10 | 5.80 | |
|
SUZ-SM71VA/PEAD-SM71JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.50 | 3.90 | 3.71 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA/SEZ-M71DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.50 | 3.90 | 3.50 | -10° | 7.10 | 5.80 | |
|
SUZ-SM71VA/PEAD-SM71JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.50 | 3.90 | 3.71 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA2/SEZ-M71DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.50 | 3.90 | 3.50 | -10° | 7.10 | 5.80 | |
|
SUZ-SM71VA2/PEAD-SM71JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.50 | 3.90 | 3.71 | -10° | 7.10 | 5.80 | |
|
SUZ-SM71VA2/PEAD-SM71JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.50 | 3.90 | 3.71 | -10° | 7.10 | 5.80 | |
|
PUZ-M71VHA/SEZ-M71DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.50 | 3.90 | 3.50 | -10° | 7.10 | 4.70 | |
|
PUZ-M71VHA/SEZ-M71DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.50 | 3.90 | 3.50 | -10° | 7.10 | 4.70 | |
|
42QCE021D8S* / 38QCE021D8S*
Wall mounted
|
CARRIER | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.26 | -10° | 6.12 | 4.75 | |
|
42QHA024D8S*/38QHA024D8S*
Wall mounted
|
CARRIER | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
42QHF024D8S*/38QHF024D8S*
Wall mounted
|
CARRIER | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
PUZ-ZM71VHA2/PCA-M71HA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.50 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PCA-M71HA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.50 | -20° | 7.10 | 4.70 | |
|
38QUS018D8S2-2/42QTD009D8S*
Cassette
|
CARRIER | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.79 | -10° | 5.40 | 4.50 | |
|
42QHG022D8S*/38QHG022D8S*
Wall mounted
|
CARRIER | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.00 | 3.74 | -10° | 6.25 | 4.90 | |
|
MSZ-HJ60VA/MUZ-HJ60VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.10 | 3.45 | -10° | 6.10 | 4.60 | |
|
42QHG024D8S*/38QHG024D8S*
Wall mounted
|
CARRIER | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.41 | -10° | 7.04 | 5.20 | |
|
SUZ-M60VA/SLZ-M60FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.00 | -10° | 5.70 | 4.60 | |
|
SUZ-M60VA2/SLZ-M60FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.00 | -10° | 5.70 | 4.60 | |
|
PUZ-ZM71VHA2/SEZ-M71DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.90 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA2/SEZ-M71DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.90 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/SEZ-M71DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.90 | -20° | 7.10 | 4.70 | |
|
SUZ-M71VA/SFZ-M71VA
S series
|
MITSUBISHI ELECTRIC | Floor standing | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA2/SFZ-M71VA2
S series
|
MITSUBISHI ELECTRIC | Floor standing | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.10 | 5.80 | |
|
38QUS018D8S2-2/42QHE09D8SH*
Wall mounted
|
CARRIER | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.56 | 4.00 | 4.29 | -10° | 5.79 | 4.50 | |
|
42QZL024D8S*/38QUS024D8S*
Ceiling suspended
|
CARRIER | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.90 | -10° | 7.20 | 5.50 | |
|
SUZ-SM60VA/PEAD-SM60JAL
P series
|
MITSUBISHI ELECTRIC | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.10 | 3.71 | -10° | 6.10 | 4.60 | |
|
SUZ-SM60VA/PEAD-SM60JA
P series
|
MITSUBISHI ELECTRIC | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.10 | 3.71 | -10° | 6.10 | 4.60 | |
|
SUZ-SM60VA2/PEAD-SM60JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.10 | 3.71 | -10° | 6.10 | 4.60 | |
|
PUZ-ZM71VHA2/PKA-M35LA2/PKA-M35LA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.78 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PKA-M35LA3/PKA-M35LA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.78 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PKA-M35LAL3/PKA-M35LAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.78 | -20° | 7.10 | 4.70 | |
|
SUZ-M60VA/MFZ-KT60VG
S series
|
MITSUBISHI ELECTRIC | Floor standing | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.21 | -10° | 6.10 | 4.60 | |
|
SUZ-M60VA2/MFZ-KT60VGK
S series
|
MITSUBISHI ELECTRIC | Floor standing | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.21 | -10° | 6.10 | 4.60 | |
|
42QSS024D8S*/38QUS024D8S*
Ducted
|
CARRIER | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.14 | -10° | 7.10 | 5.40 | |
|
SUZ-M71VA/PSA-M71KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.21 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA2/PSA-M71KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.21 | -10° | 7.10 | 5.80 | |
|
PUZ-ZM71VHA2/PSA-M71KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.25 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PSA-M71KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.25 | -20° | 7.10 | 4.80 | |
|
38WH5M100C1A0TEE/40WHHW046D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 4.14 | -20° | 7.10 | 4.93 | |
|
SUZ-M60VA/SEZ-M60DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.20 | 3.61 | -10° | 6.10 | 4.60 | |
|
SUZ-M60VA/SEZ-M60DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.20 | 3.61 | -10° | 6.10 | 4.60 |