Filters · 4 active
Manufacturer:
COLIBRI
NORD
Vulcano
AIRCLASS
(1)
AIRWELL
(23)
ATLANTIC
(9)
AUX
(21)
BOSCH
(24)
BRYANT
(1)
Buderus
(12)
CARRIER
(26)
CIAT
(7)
CONFORT AIR
(1)
Candy
(2)
DAIKIN
(148)
EQUATION
(3)
FUJI ELECTRIC
(14)
FUJITSU
(37)
Fujitsu Atlantic
(17)
GENERAL
(18)
GREE
(23)
GSS
(1)
HAIER
(142)
HEC
(0)
HEIWA
(2)
HISENSE
(59)
HITACHI
(39)
IVT
(1)
Inventor
(32)
KAYSUN
(7)
LG
(72)
MIDEA
(157)
MITSUBISHI ELECTRIC
(103)
Mitsubishi Heavy Industries
(33)
Nobu
(2)
PANASONIC
(57)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(32)
THERMOR
(15)
TOSHIBA
(47)
Viessmann
(3)
WESTPOINT
(5)
YORK
(5)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
UE-E3CM 53/2 / UI-L2CU M 26 + UI-L2CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
UE-EC 70 / UI-ECU M 70
Easy 3 Cool
|
Vulcano | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
AS71QAIN/US71QAOD
NORD - P plus
|
NORD | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 6.80 | 5.00 | |
|
UE-E3CM 79/3 / UI-L2CU M 26 + UI-L2CU M 53
Easy Cool M
|
Vulcano | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.80 | 5.50 | |
|
3N75WEAFRA/AS35SAT1-W+AS35SAT1-W
NORD - Multi
|
NORD | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.00 | -10° | 6.50 | 5.50 | |
|
3N75WEAFRA-W/AS35SAT1-W+AS35SAT1-W
NORD - Multi
|
NORD | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.00 | -10° | 6.50 | 5.50 | |
|
4N80WEAFRA/AS50SAT1-W+AS35SAT1-W
NORD - Multi
|
NORD | Wall mounted | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.00 | -10° | 7.10 | 5.60 | |
|
4N80WEAFRA-W/AS50SAT1-W+AS35SAT1-W
NORD - Multi
|
NORD | Wall mounted | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.00 | -10° | 7.10 | 5.60 | |
|
UE-E3CM 62/2 / UI-L2CU M 26 + UI-L2CU M 35
Easy Cool M
|
Vulcano | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 6.10 | 5.70 | |
|
COLI24R8SHF/COLI24R8SHC
Wall mounted
|
COLIBRI | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
UE-E3CM 53/2 / UI-E3CU M 26 + UI-E3CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
3N60WEAFRA-W/AS25SAT1-W+AS35SAT1-W
NORD - Multi
|
NORD | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.00 | -10° | 5.20 | 4.60 | |
|
UE-L2C 70 / UI-L2CU M 70
Line cool
|
Vulcano | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
NB71CEAHRA/1N71WEAFRA-W
NORD - Cassette
|
NORD | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.72 | -10° | 7.10 | 5.50 | |
|
NB71CEAHRA/1N71WEAFRA
NORD - Cassette
|
NORD | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.72 | -10° | 7.10 | 5.50 | |
|
AS50QUA1-H/1U50QUA1
NORD - P Premium
|
NORD | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 5.30 | 4.60 | |
|
ND71MFAHRA/1N71WEAFRA
NORD - MSP Duct
|
NORD | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
ND71MFAHRA/1N71WEAFRA-W
NORD - MSP Duct
|
NORD | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
AS71QUA1-H/1U71QUA1
NORD - P Premium
|
NORD | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS50SAT1-W/US50SAT1
NORD - S
|
NORD | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 4.00 | -10° | 5.30 | 4.70 | |
|
ND50MDAHRA/1N50KEAFRA
NORD - MSP Duct
|
NORD | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.20 | 4.00 | -10° | 5.00 | 4.50 | |
|
ND50MDAHRA/1N50KEAFRA-W
NORD - MSP Duct
|
NORD | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.20 | 4.00 | -10° | 5.00 | 4.50 | |
|
NB71MBAHRA/1N71WEAFRA-W
NORD - Mini Cassette
|