Filters · 4 active
Manufacturer:
Candy
GENERAL
RIELLO
AIRCLASS
(1)
AIRWELL
(23)
ATLANTIC
(9)
AUX
(21)
BOSCH
(24)
BRYANT
(1)
Buderus
(12)
CARRIER
(26)
CIAT
(7)
COLIBRI
(1)
CONFORT AIR
(1)
DAIKIN
(148)
EQUATION
(3)
FUJI ELECTRIC
(14)
FUJITSU
(37)
Fujitsu Atlantic
(17)
GREE
(23)
GSS
(1)
HAIER
(142)
HEC
(0)
HEIWA
(2)
HISENSE
(59)
HITACHI
(39)
IVT
(1)
Inventor
(32)
KAYSUN
(7)
LG
(72)
MIDEA
(157)
MITSUBISHI ELECTRIC
(103)
Mitsubishi Heavy Industries
(33)
NORD
(16)
Nobu
(2)
PANASONIC
(57)
Rotenso
(0)
SAMSUNG
(32)
THERMOR
(15)
TOSHIBA
(47)
Viessmann
(3)
Vulcano
(6)
WESTPOINT
(5)
YORK
(5)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOHG24KATA/AUXG24KVLA
AUXG**K
|
GENERAL | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.80 | 3.61 | -15° | 6.80 | 5.40 | |
|
CY-18QBIN-A/CY-18QBOUT-A
Candy Aira 2025
|
Candy | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.00 | 4.60 | |
|
WR070HJM8-1/AIR070HJM8-1
Wall mounted
|
RIELLO | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
AIX250HIM8-2/KC225HIM8*
Cassette
|
RIELLO | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.79 | -10° | 5.40 | 4.50 | |
|
CY-24RAIN-A/CY-24RAOUT-A
Candy Pura 2025
|
Candy | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.71 | -10° | 6.20 | 4.60 | |
|
WR570HJM8*/AIR570HJM8
Wall mounted
|
RIELLO | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.41 | -10° | 7.04 | 5.20 | |
|
AOHG24KATA/AUXG24KRLB
AUXG**K
|
GENERAL | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.81 | -15° | 6.80 | 5.40 | |
|
AOHG24KATA/ARXG24KMLA
ARXG**K
|
GENERAL | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOHG24KATA/ARXH24KMTAP
ARX**K
|
GENERAL | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.81 | -15° | 6.80 | 5.40 | |
|
AOHG24KBTA3/ASHG12KMCC/ASHG12KMCC
AOH**K Multi
|
GENERAL | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.83 | -15° | 6.80 | 5.80 | |
|
SC270HIDS8/AIC270HIDS8
Ceiling suspended
|
RIELLO | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.90 | -10° | 7.20 | 5.50 | |
|
AOHG22KBTB/ABHG22KRTA
ABH**K
|
GENERAL | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
DC270HIDS8/AIC270HIDS8
Ducted
|
RIELLO | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.14 | -10° | 7.10 | 5.40 | |
|
AOHG18KBTA3/ASHG07KMCC/ASHG12KMCC
AOH**K Multi
|
GENERAL | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
AOHG22KBTB/ARXG22KMLA
ARH**K
|
GENERAL | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.74 | -15° | 6.00 | 4.80 | |
|
AOHG22KBTB/ARXG22KMLB
ARH**K
|
GENERAL | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.74 | -15° | 6.00 | 4.80 | |
|
AOHG18KLTA/ASHG18KLCA
ASH**K
|
GENERAL | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOHG18KLCA/ASHG18KLCA
ASH**K
|
GENERAL | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
WR670HJM8*/AIR670HJM8*
Wall mounted
|
RIELLO | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.20 | 3.74 | -10° | 6.85 | 5.00 | |
|
AOHG22KBTB/AUXG22KVLA
AUH**K
|
GENERAL | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.74 | -15° | 6.00 | 4.80 | |
|
AIX250HIM8-2/DC225HIM8*
Ducted
|
RIELLO | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 4.29 | -10° | 5.80 | 4.60 | |
|
AOHG18KMTA/ASHG18KMTE
ASH**K
|
GENERAL | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.77 | 4.60 | 4.04 | -15° | 5.20 | 4.80 | |
|
AOHG22KBTB/ARXG22KHTAP
ARH**K
|
GENERAL | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.87 | -15° | 6.00 | 4.80 | |
|
AOHG22KBTB/ARXH22KMTAP
ARX**K
|
GENERAL | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 6.00 | 4.80 | |
|
AOHH18KMTG/ASHH18KMTGL
ASH**K
|
GENERAL | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 4.04 | -15° | 5.20 | 4.80 | |
|
AOHG22KBTB/AUXG22KRLB
AUH**K
|
GENERAL | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.40 | 3.85 | -15° | 6.00 | 4.80 | |
|
AOHG18KBTA3/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG
AOH**K Multi
|
GENERAL | Wall mounted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.89 | -15° | 5.40 | 5.00 |