Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(2)
BRYANT
(0)
Buderus
(2)
CARRIER
(11)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(1)
Candy
(0)
DAIKIN
(94)
EQUATION
(0)
FUJI ELECTRIC
(14)
FUJITSU
(37)
Fujitsu Atlantic
(17)
GENERAL
(18)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(30)
IVT
(0)
Inventor
(5)
KAYSUN
(0)
LG
(4)
MIDEA
(9)
MITSUBISHI ELECTRIC
(50)
Mitsubishi Heavy Industries
(16)
NORD
(0)
Nobu
(0)
PANASONIC
(57)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(24)
THERMOR
(0)
TOSHIBA
(47)
Viessmann
(0)
Vulcano
(1)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MXZ-3E54VA/MSZ-EF18VE3W(B)(S)/MSZ-EF35VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.54 | -15° | 5.30 | 4.80 | |
|
MXZ-4E72VA/MSZ-EF22VE3W(B)(S)/MSZ-EF50VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.70 | 3.80 | 3.11 | -15° | 6.40 | 5.50 | |
|
MXZ-3E68VA/MSZ-EF18VE3W(B)(S)/MSZ-EF50VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.50 | 3.80 | 2.97 | -15° | 6.20 | 5.10 | |
|
ARXM71R / FAA71B
ARXM
|
DAIKIN | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.77 | 3.81 | 3.19 | -15° | 6.80 | 4.50 | |
|
ARXM71A / FAA71B
ARXM
|
DAIKIN | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.77 | 3.81 | 3.19 | -15° | 6.80 | 4.50 | |
|
MXZ-4E83VA/MSZ-EF42VE3W(B)(S)/MSZ-EF42VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 2.97 | -15° | 7.00 | 5.90 | |
|
RAV-GM801ATP-E/RAV-HM801FT-E
DI
|
TOSHIBA | Floor standing | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.89 | 3.81 | 2.41 | -15° | 6.70 | 4.70 | |
|
AOYG24KATA/AUXG24KVLA
AUXG**K
|
FUJITSU | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.80 | 3.61 | -15° | 6.80 | 5.40 | |
|
ROG24KATA/RCG24KVLA
RCG**K
|
FUJI ELECTRIC | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.80 | 3.61 | -15° | 6.80 | 5.40 | |
|
AOHG24KATA/AUXG24KVLA
AUXG**K
|
GENERAL | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.80 | 3.61 | -15° | 6.80 | 5.40 | |
|
AOEG24KATA/AUXG24KVLA
AUXG**K
|
FUJITSU | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.80 | 3.61 | -15° | 6.80 | 5.40 | |
|
AOYG24KATA/AUXG24KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.80 | 3.61 | -15° | 6.80 | 5.40 | |
|
RXM60R / FDXM60F9
RXM
|
DAIKIN | Ducted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.56 | 3.80 | 3.21 | -15° | 6.00 | 4.60 | |
|
CU-3Z68TBE/CS-Z35ZKEW/CS-Z35ZKEW
2023
|
PANASONIC | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.56 | -15° | 6.80 | 4.80 | |
|
CU-3TZ52TBE/CS-TZ25ZKEW/CS-TZ42ZKEW
2023
|
PANASONIC | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.82 | -15° | 5.20 | 4.80 | |
|
CU-4Z68TBE/CS-Z35ZKEW/CS-Z35ZKEW
2023
|
PANASONIC | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.56 | -15° | 6.80 | 4.80 | |
|
RAV-GV801ATP-E/RAV-HM801KRTP-E
DIC
|
TOSHIBA | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.75 | 3.90 | 3.18 | -15° | 6.70 | 4.80 | |
|
CU-4Z80TBE/CS-Z35ZKEW/CS-TZ71ZKEW
2023
|
PANASONIC | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.90 | 3.85 | -15° | 8.00 | 5.50 | |
|
ARXM71A / FHA71A9
ARXM
|
DAIKIN | Ceiling suspended | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.87 | 3.80 | 3.60 | -15° | 6.80 | 4.50 | |
|
5MWXM90A9 / FTXM71A / FTXP20N9
5MWXM
|
DAIKIN | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.97 | 3.55 | -15° | 8.00 | 4.50 | |
|
AR40H24C1AMN/AR40H24C1AMX
RAC
|
SAMSUNG | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.00 | -15° | 7.03 | 4.71 | |
|
AR40F24C0AMN/AR40F24C0AMX
RAC
|
SAMSUNG | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.00 | -15° | 7.03 | 4.71 | |
|
AR40F24C0BMN/AR40F24C0BMX
RAC
|
SAMSUNG | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.00 | -15° | 7.03 | 4.71 | |
|
ARXM71R / FBA71A9
ARXM
|
DAIKIN | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.57 | 3.81 | 3.67 | -15° | 6.80 | 4.50 | |
|
ARXM71A / FBA71A9
ARXM
|
DAIKIN | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.57 | 3.81 | 3.67 | -15° | 6.80 | 4.50 | |
|
MU4R25 U22 / MJ07PC NSJ / MJ18PC NSK
MU
|
LG | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.81 | 3.87 | -15° | 6.40 | 5.10 | |
|
ARXM71R / FCAG71B
ARXM
|
DAIKIN | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.87 | 4.00 | 3.38 | -15° | 6.80 | 4.50 | |
|
ARXM71A / FCAG71B
ARXM
|
DAIKIN | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.87 | 4.00 | 3.38 | -15° | 6.80 | 4.50 | |
|
RPIL-2.0UNE1NH / RAS-2.0UNESNH1
Primairy R410 series
|
HITACHI | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.40 | -15° | 5.28 | 4.80 | |
|
5MWXM68A9 / FTXM50A / FTXM20A
5MWXM
|
DAIKIN | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.74 | 3.87 | 3.21 | -15° | 6.80 | 4.50 | |
|
5MWXM68A9 / FTXM35A / FTXM35A
5MWXM
|
DAIKIN | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.68 | 3.82 | 3.07 | -15° | 6.80 | 4.80 | |
|
2MXM68A9 / FTXM50R / FTXM20R
2MXM
|
DAIKIN | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.75 | 3.90 | 3.82 | -15° | 6.80 | 4.50 | |
|
3MXM68A9 / FTXM20R / FTXM50R
3MXM
|
DAIKIN | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.75 | 3.90 | 3.82 | -15° | 6.80 | 4.50 | |
|
4MXM68A9 / FTXM20R / FTXM50R
4MXM
|
DAIKIN | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.75 | 3.90 | 3.82 | -15° | 6.80 | 4.50 | |
|
2MXM68A9 / FTXM50A / FTXM20A
2MXM
|
DAIKIN | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.75 | 3.90 | 3.82 | -15° | 6.80 | 4.50 | |
|
3MXM68A9 / FTXM20A / FTXM50A
3MXM
|
DAIKIN | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.75 | 3.90 | 3.82 | -15° | 6.80 | 4.50 | |
|
4MXM68A9 / FTXM20A / FTXM50A
4MXM
|
DAIKIN | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.75 | 3.90 | 3.82 | -15° | 6.80 | 4.50 | |
|
PUZ-ZM71VHA2/PCA-M71HA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.50 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PCA-M71HA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.50 | -20° | 7.10 | 4.70 | |
|
5MWXM68A9 / FTXM50A / CTXM15A
5MWXM
|
DAIKIN | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.85 | 3.85 | 3.35 | -15° | 6.50 | 4.50 | |
|
2MXM68A9 / FTXM50R / CTXM15R
2MXM
|
DAIKIN | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.83 | 3.87 | 3.86 | -15° | 6.50 | 4.50 | |
|
3MXM68A9 / CTXM15R / FTXM50R
3MXM
|
DAIKIN | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.83 | 3.87 | 3.86 | -15° | 6.50 | 4.50 | |
|
4MXM68A9 / CTXM15R / FTXM50R
4MXM
|
DAIKIN | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.83 | 3.87 | 3.86 | -15° | 6.50 | 4.50 | |
|
2MXM68A9 / FTXM50A / CTXM15A
2MXM
|
DAIKIN | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.83 | 3.87 | 3.86 | -15° | 6.50 | 4.50 | |
|
3MXM68A9 / CTXM15A / FTXM50A
3MXM
|
DAIKIN | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.83 | 3.87 | 3.86 | -15° | 6.50 | 4.50 | |
|
4MXM68A9 / CTXM15A / FTXM50A
4MXM
|
DAIKIN | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.83 | 3.87 | 3.86 | -15° | 6.50 | 4.50 | |
|
5MWXM90A9 / FTXM50A / FTXM42A
5MWXM
|
DAIKIN | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 3.98 | 3.23 | -15° | 8.00 | 5.20 | |
|
AC100RXADKG/AC100RNTDKG
CAC
|
SAMSUNG | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 2.82 | -20° | 9.50 | 5.60 | |
|
AC100RXADNG/AC100RNTDKG
CAC
|
SAMSUNG | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 2.98 | -20° | 9.50 | 5.60 | |
|
RZAG60A / FDXM60F9
RZAG
|
DAIKIN | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.90 | 3.30 | -20° | 6.00 | 4.50 |