Filters · 2 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(4)
ATLANTIC
(5)
AUX
(4)
BOSCH
(9)
BRYANT
(0)
Buderus
(4)
CARRIER
(11)
CIAT
(2)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(88)
EQUATION
(1)
FUJI ELECTRIC
(4)
FUJITSU
(12)
Fujitsu Atlantic
(5)
GENERAL
(7)
GREE
(15)
GSS
(0)
HAIER
(42)
HEC
(0)
HEIWA
(1)
HISENSE
(21)
HITACHI
(28)
IVT
(1)
Inventor
(9)
KAYSUN
(1)
LG
(17)
MIDEA
(29)
MITSUBISHI ELECTRIC
(61)
Mitsubishi Heavy Industries
(23)
NORD
(5)
Nobu
(0)
PANASONIC
(37)
RIELLO
(2)
Rotenso
(0)
SAMSUNG
(10)
THERMOR
(4)
TOSHIBA
(25)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(5)
YORK
(0)
Mounting:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RZASG71MV1 / FBA35A9 / FBA35A9
RZASG
|
DAIKIN | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.43 | 3.82 | 3.82 | -10° | 6.80 | 4.50 | |
|
AZAS71MV1 / FBA71A9
AZAS
|
DAIKIN | Ducted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.57 | 3.81 | 3.73 | -10° | 6.80 | 4.50 | |
|
SUZ-SM71VA/PLA-SM71EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.00 | 3.90 | 3.50 | -10° | 7.10 | 5.80 | |
|
SUZ-SM71VA2/PLA-SM71EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.00 | 3.90 | 3.50 | -10° | 7.10 | 5.80 | |
|
CU-3TZ52TBE/CS-TZ25ZKEW/CS-TZ42ZKEW
2023
|
PANASONIC | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.82 | -15° | 5.20 | 4.80 | |
|
ARXM71A / FHA71A9
ARXM
|
DAIKIN | Ceiling suspended | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.87 | 3.80 | 3.60 | -15° | 6.80 | 4.50 | |
|
ARXM71R / FBA71A9
ARXM
|
DAIKIN | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.57 | 3.81 | 3.67 | -15° | 6.80 | 4.50 | |
|
ARXM71A / FBA71A9
ARXM
|
DAIKIN | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.57 | 3.81 | 3.67 | -15° | 6.80 | 4.50 | |
|
RZASG71MV1 / FHA71A9
RZASG
|
DAIKIN | Ceiling suspended | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.95 | 3.90 | 3.75 | -10° | 6.80 | 4.50 | |
|
AB71S2SG1FA/1U71S2ST1FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.08 | 4.00 | 3.30 | -10° | 7.10 | 5.00 | |
|
UUC1 U40 / UM30F NA0
U4
|
LG | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.71 | -10° | 7.50 | 5.40 | |
|
GVH24AMXF-K6DNC7A
Floor-standing
|
GREE | Floor standing | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.39 | -10° | 7.20 | 5.60 | |
|
2MXM68A9 / FTXM50R / FTXM20R
2MXM
|
DAIKIN | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.75 | 3.90 | 3.82 | -15° | 6.80 | 4.50 | |
|
3MXM68A9 / FTXM20R / FTXM50R
3MXM
|
DAIKIN | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.75 | 3.90 | 3.82 | -15° | 6.80 | 4.50 | |
|
4MXM68A9 / FTXM20R / FTXM50R
4MXM
|
DAIKIN | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.75 | 3.90 | 3.82 | -15° | 6.80 | 4.50 | |
|
2MXM68A9 / FTXM50A / FTXM20A
2MXM
|
DAIKIN | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.75 | 3.90 | 3.82 | -15° | 6.80 | 4.50 | |
|
3MXM68A9 / FTXM20A / FTXM50A
3MXM
|
DAIKIN | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.75 | 3.90 | 3.82 | -15° | 6.80 | 4.50 | |
|
4MXM68A9 / FTXM20A / FTXM50A
4MXM
|
DAIKIN | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.75 | 3.90 | 3.82 | -15° | 6.80 | 4.50 | |
|
PUZ-ZM71VHA2/PCA-M71HA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.50 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PCA-M71HA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.50 | -20° | 7.10 | 4.70 | |
|
2MXM68A9 / FTXM50R / CTXM15R
2MXM
|
DAIKIN | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.83 | 3.87 | 3.86 | -15° | 6.50 | 4.50 | |
|
3MXM68A9 / CTXM15R / FTXM50R
3MXM
|
DAIKIN | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.83 | 3.87 | 3.86 | -15° | 6.50 | 4.50 | |
|
4MXM68A9 / CTXM15R / FTXM50R
4MXM
|
DAIKIN | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.83 | 3.87 | 3.86 | -15° | 6.50 | 4.50 | |
|
2MXM68A9 / FTXM50A / CTXM15A
2MXM
|
DAIKIN | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.83 | 3.87 | 3.86 | -15° | 6.50 | 4.50 | |
|
3MXM68A9 / CTXM15A / FTXM50A
3MXM
|
DAIKIN | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.83 | 3.87 | 3.86 | -15° | 6.50 | 4.50 | |
|
4MXM68A9 / CTXM15A / FTXM50A
4MXM
|
DAIKIN | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.83 | 3.87 | 3.86 | -15° | 6.50 | 4.50 | |
|
RZASG71MV1 / FUA71A
RZASG
|
DAIKIN | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.16 | 3.90 | 3.89 | -10° | 6.80 | 4.50 | |
|
GWH24ALEXE-K6DNA2B
MONOSPLITS
|
GREE | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.70 | -10° | 6.20 | 4.70 | |
|
CU-3Z52TBE/CS-Z35ZKEW/CS-Z35ZKEW
2023
|
PANASONIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 4.02 | -15° | 5.20 | 5.00 | |
|
RAS-2HVRC3 / RPK-2.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.77 | 3.88 | 3.91 | -25° | 5.00 | 5.00 | |
|
CU-3TZ52CBE/CS-TZ42CKEW/CS-TZ42CKEW
2025
|
PANASONIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.60 | -15° | 5.20 | 4.80 | |
|
AS 018 JDB.UI/ 1U 018 JDB.UE
Kazendo
|
ATLANTIC | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SF1FA-MB3/1U50S2SJ2FA-2
Super Match mono-Flair Plus
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SF1FA-BH/1U50S2SJ2FA-2
Super Match mono-Flair Plus
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SF1FA-MW3/1U50S2SJ2FA-2
Super Match mono-Flair Plus
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SF1FA-WH/1U50S2SJ2FA-2
Super Match mono-Flair Plus
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SJ1FA-3/1U50S2SJ2FA-2
Super Match mono-Jade
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
NAGANO MURALE PURE IM52V2-NG / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
NAGANO MURALE PURE NOIRE IM52V2-NGN / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SF1FA-MW3/1U50KEFFRA-1
Flexis electric heater
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SF1FA-MB3/1U50KEFFRA-1
Flexis electric heater
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
Virtus-18K-IN/Virtus-18K-OUT
Wall mounted - Tundra Plus
|
EQUATION | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
NAGANO MURALE PURE IM52V3-NG / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
NAGANO MURALE PURE NOIRE IM52V3-NGN / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50PDPHRA-PRE/1U50KEPFRA-PRE
Pearl Premium
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 3.80 | 4.00 | -10° | 5.30 | 4.60 | |
|
AS50PDPHRA-PRE/1U50KEPFRA-H
Pearl Premium Electric Heater
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 3.80 | 4.00 | -10° | 5.30 | 4.60 | |
|
UI 5,3 kW MURAO SMART BLANC & UE MONO 5,3 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 3.80 | 4.00 | -10° | 5.30 | 4.60 | |
|
2MXM68A9 / FTXM35R / FTXM35R
2MXM
|
DAIKIN | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.97 | 4.00 | 3.81 | -15° | 6.80 | 4.80 | |
|
3MXM68A9 / FTXM35R / FTXM35R
3MXM
|
DAIKIN | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.97 | 4.00 | 3.81 | -15° | 6.80 | 4.80 | |
|
4MXM68A9 / FTXM35R / FTXM35R
4MXM
|
DAIKIN | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.97 | 4.00 | 3.81 | -15° | 6.80 | 4.80 |