Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(1)
ATLANTIC
(1)
AUX
(4)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(2)
CIAT
(1)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(13)
EQUATION
(0)
FUJI ELECTRIC
(2)
FUJITSU
(6)
Fujitsu Atlantic
(2)
GENERAL
(1)
GREE
(0)
GSS
(0)
HAIER
(7)
HEC
(0)
HEIWA
(0)
HISENSE
(2)
HITACHI
(2)
IVT
(0)
Inventor
(2)
KAYSUN
(0)
LG
(5)
MIDEA
(0)
MITSUBISHI ELECTRIC
(9)
Mitsubishi Heavy Industries
(3)
NORD
(0)
Nobu
(0)
PANASONIC
(5)
RIELLO
(1)
Rotenso
(0)
SAMSUNG
(4)
THERMOR
(0)
TOSHIBA
(3)
Viessmann
(1)
Vulcano
(0)
WESTPOINT
(0)
YORK
(1)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
ARXM71A / FHA71A9
ARXM
|
DAIKIN | Ceiling suspended | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.87 | 3.80 | 3.60 | -15° | 6.80 | 4.50 | |
|
RZASG71MV1 / FHA71A9
RZASG
|
DAIKIN | Ceiling suspended | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.95 | 3.90 | 3.75 | -10° | 6.80 | 4.50 | |
|
AC71S2SG2FA(H)/1U71S2SR2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.71 | -10° | 7.10 | 5.00 | |
|
AC 024 DB.UI/1U 024 DC.UE
Ceiling suspended
|
ATLANTIC | Ceiling suspended | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.41 | 4.00 | 3.26 | -10° | 7.10 | 5.00 | |
|
PUZ-ZM71VHA2/PCA-M71HA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.50 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PCA-M71HA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.50 | -20° | 7.10 | 4.70 | |
|
RZASG71MV1 / FUA71A
RZASG
|
DAIKIN | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.16 | 3.90 | 3.89 | -10° | 6.80 | 4.50 | |
|
RXM60R / FHA60A9
RXM
|
DAIKIN | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.08 | 3.87 | 3.32 | -15° | 5.70 | 4.71 | |
|
AOYG24KATA/ABYG24KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
ROG24KATA/RYG24KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOEG24KATA/ABEG24KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOEG24KATA/ABYG24KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOYG24KATA/ABYG24KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
U7RS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
YUKF24BYEEBMO-1/YFKF24BXEEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
AC71S2SG1FA/1U71S2SR2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.10 | 5.00 | |
|
AC71S2SG2FA(H)/1U71S2SR3FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 7.10 | 5.00 | |
|
YDAM-070R-09M22/FDHM-070N-09M22
OASIS
|
AIRWELL | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 7.10 | 5.00 | |
|
42QZL024D8S*/38QUS024D8S*
Ceiling suspended
|
CARRIER | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.90 | -10° | 7.20 | 5.50 | |
|
42HU24VDS8C/38HU24VDS8C
Ceiling suspended
|
CIAT | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.90 | -10° | 7.20 | 5.50 | |
|
SC270HIDS8/AIC270HIDS8
Ceiling suspended
|
RIELLO | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.90 | -10° | 7.20 | 5.50 | |
|
AOYG22KBTB/ABYG22KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
AOHG22KBTB/ABHG22KRTA
ABH**K
|
GENERAL | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
ROG22KBTB/RYG22KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
AOEG22KBTB/ABEG22KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
AOEG22KBTB/ABYG22KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
AOYG22KBTB/ABYG22KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
AL-H18/4DR3HB3(U) / AUCF-H18/4DR3HA2
F-Ceiling suspended
|
AUX | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.77 | -10° | 5.30 | 4.50 | |
|
RXYL52M-T1B/FDCF52F-B
F-Ceiling suspended
|
AUX | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.77 | -10° | 5.30 | 4.50 | |
|
AC71S2SG1FA/1U71S2ST1FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 4.00 | 3.52 | -10° | 7.10 | 5.00 | |
|
AC100RXADKG/AC100RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.44 | -20° | 10.00 | 5.20 | |
|
AC100RXADNG/AC100RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -20° | 10.00 | 5.20 | |
|
AL-H24/4DR3HB3(U) / AUCF-H24/4DR3HA2
F-Ceiling suspended
|
AUX | Ceiling suspended | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 7.03 | 5.50 | |
|
RXYL71M-T1B/FDCF71F-B
F-Ceiling suspended
|
AUX | Ceiling suspended | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 7.03 | 5.50 | |
|
RAV-GM801ATP-E/RAV-HM801CTP-E
DI
|
TOSHIBA | Ceiling suspended | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.21 | 3.62 | -15° | 6.90 | 5.10 | |
|
SUZ-M60VA/PCA-M60KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 4.00 | -10° | 6.10 | 4.60 | |
|
SUZ-M60VA2/PCA-M60KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 4.00 | -10° | 6.10 | 4.60 | |
|
UUC1 U40 / UV36F N20
U4
|
LG | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.70 | -10° | 9.50 | 5.50 | |
|
AC71S2SG1FA(H)/1U71S2SR2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 7.10 | 5.00 | |
|
42QZL024D8S*/38QUS024D8SX*
Ceiling suspended
|
CARRIER | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
Vitoclima100-SIFCAA100MFA070/Vitoclima100-SPROOFAA100MFP070
Ceiling suspended
|
Viessmann | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
U7iRS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
FDC71VNP-W/FDE71VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.74 | 4.32 | 3.62 | -15° | 7.10 | 5.70 | |
|
PUZ-M71VHA/PCA-M71KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.61 | -10° | 7.10 | 4.70 | |
|
SUZ-M71VA/PCA-M71KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.61 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA2/PCA-M71KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.61 | -10° | 7.10 | 5.80 | |
|
U-71PZ3E5A / S-6071PT3E
2021
|
PANASONIC | Ceiling suspended | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.30 | 4.20 | -15° | 6.80 | 4.70 | |
|
AUW71U4RJ7/AVT71UR4RB8
Super Inverter R32
|
HISENSE | Ceiling suspended | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.20 | 3.72 | -10° | 7.00 | 5.50 | |
|
AC71S2SG1FA(H)/1U71S2ST1FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 4.20 | 3.52 | -10° | 7.10 | 5.00 | |
|
RAS-2HVRC3 / RPC-2.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.00 | 4.09 | -25° | 5.00 | 5.00 |