Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(4)
ATLANTIC
(1)
AUX
(6)
BOSCH
(3)
BRYANT
(0)
Buderus
(1)
CARRIER
(5)
CIAT
(3)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(44)
EQUATION
(0)
FUJI ELECTRIC
(5)
FUJITSU
(18)
Fujitsu Atlantic
(8)
GENERAL
(7)
GREE
(1)
GSS
(0)
HAIER
(23)
HEC
(0)
HEIWA
(0)
HISENSE
(8)
HITACHI
(10)
IVT
(0)
Inventor
(4)
KAYSUN
(3)
LG
(17)
MIDEA
(14)
MITSUBISHI ELECTRIC
(45)
Mitsubishi Heavy Industries
(8)
NORD
(5)
Nobu
(0)
PANASONIC
(11)
RIELLO
(3)
Rotenso
(0)
SAMSUNG
(8)
THERMOR
(1)
TOSHIBA
(9)
Viessmann
(2)
Vulcano
(0)
WESTPOINT
(0)
YORK
(2)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AD71S2SS1FA/1U71S2ST1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.41 | 3.80 | 3.34 | -10° | 7.10 | 5.00 | |
|
AZAS71MV1 / ADEA71A
AZAS
|
DAIKIN | Ducted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.44 | 3.81 | 3.62 | -10° | 6.80 | 4.50 | |
|
RZASG71MV1 / FBA35A9 / FBA35A9
RZASG
|
DAIKIN | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.43 | 3.82 | 3.82 | -10° | 6.80 | 4.50 | |
|
AZAS71MV1 / FBA71A9
AZAS
|
DAIKIN | Ducted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.57 | 3.81 | 3.73 | -10° | 6.80 | 4.50 | |
|
RXM60R / FDXM60F9
RXM
|
DAIKIN | Ducted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.56 | 3.80 | 3.21 | -15° | 6.00 | 4.60 | |
|
ARXM71A / FHA71A9
ARXM
|
DAIKIN | Ceiling suspended | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.87 | 3.80 | 3.60 | -15° | 6.80 | 4.50 | |
|
ARXM71R / FBA71A9
ARXM
|
DAIKIN | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.57 | 3.81 | 3.67 | -15° | 6.80 | 4.50 | |
|
ARXM71A / FBA71A9
ARXM
|
DAIKIN | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.57 | 3.81 | 3.67 | -15° | 6.80 | 4.50 | |
|
RZAG60B / FDXM60F9
RZAG
|
DAIKIN | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.90 | 3.30 | -10° | 6.00 | 4.50 | |
|
RZAG60B / FNA60A9
RZAG
|
DAIKIN | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.90 | 3.30 | -10° | 6.00 | 4.50 | |
|
SUZ-M71VA/SEZ-M71DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.50 | 3.90 | 3.50 | -10° | 7.10 | 5.80 | |
|
SUZ-SM71VA/PEAD-SM71JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.50 | 3.90 | 3.71 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA/SEZ-M71DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.50 | 3.90 | 3.50 | -10° | 7.10 | 5.80 | |
|
SUZ-SM71VA/PEAD-SM71JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.50 | 3.90 | 3.71 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA2/SEZ-M71DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.50 | 3.90 | 3.50 | -10° | 7.10 | 5.80 | |
|
SUZ-SM71VA2/PEAD-SM71JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.50 | 3.90 | 3.71 | -10° | 7.10 | 5.80 | |
|
SUZ-SM71VA2/PEAD-SM71JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.50 | 3.90 | 3.71 | -10° | 7.10 | 5.80 | |
|
RZASG71MV1 / FHA71A9
RZASG
|
DAIKIN | Ceiling suspended | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.95 | 3.90 | 3.75 | -10° | 6.80 | 4.50 | |
|
PUZ-M71VHA/SEZ-M71DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.50 | 3.90 | 3.50 | -10° | 7.10 | 4.70 | |
|
PUZ-M71VHA/SEZ-M71DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.50 | 3.90 | 3.50 | -10° | 7.10 | 4.70 | |
|
AC71S2SG2FA(H)/1U71S2SR2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.71 | -10° | 7.10 | 5.00 | |
|
M2OE-18HFN8-Q/MTIU-09HWFNX(GA)+MTIU-09HWFNX(GA)
M2OE-18HFN8-Q
|
MIDEA | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.30 | 4.60 | |
|
M2OE-18HFN8-Q/MTIU-09HWFNX-QRD0W(GA)+MTIU-09HWFNX-QRD0W(GA)
M2OE-18HFN8-Q
|
MIDEA | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.30 | 4.60 | |
|
CL5000M 53/2 E / CL5000iM D 26 E + CL5000iM D 26 E
Climate 5000 M
|
BOSCH | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.30 | 4.60 | |
|
AC-5,3 MS / AC166i-2,6 MS D + AC166i-2,6 MS D
Logacool
|
Buderus | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.30 | 4.60 | |
|
M2OE-18HFN8-Q-GR/MTIU-09HWFNX-QRD0W(GA)-GR+MTIU-09HWFNX-QRD0W(GA)-GR
M2OE-18HFN8-Q
|
MIDEA | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.30 | 4.60 | |
|
RPIL-2.0UNE1NH / RAS-2.0UNESNH1
Primairy R410 series
|
HITACHI | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.40 | -15° | 5.28 | 4.80 | |
|
AD50S2SM3FA/1U50S2SJ2FA-2
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.00 | 4.50 | |
|
UUC1 U40 / UM30F NA0
U4
|
LG | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.71 | -10° | 7.50 | 5.40 | |
|
AD71S2SM3FA/1U71S2SR2FA
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 7.10 | 5.00 | |
|
AD71S2SS1FA/1U71S2SR2FA
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.73 | -10° | 7.10 | 5.00 | |
|
NAGANO GAINABLE MP IG71MP-NG / E1U70LV2-NG
NAGANO GAINABLE MOYENNE PRESSION
|
THERMOR | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 7.10 | 5.00 | |
|
AC 024 DB.UI/1U 024 DC.UE
Ceiling suspended
|
ATLANTIC | Ceiling suspended | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.41 | 4.00 | 3.26 | -10° | 7.10 | 5.00 | |
|
PUZ-ZM71VHA2/PCA-M71HA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.50 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PCA-M71HA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.50 | -20° | 7.10 | 4.70 | |
|
RZASG71MV1 / FUA71A
RZASG
|
DAIKIN | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.16 | 3.90 | 3.89 | -10° | 6.80 | 4.50 | |
|
AD71S2SS1FA(H)/1U71S2ST1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.41 | 4.00 | 3.34 | -10° | 7.10 | 5.00 | |
|
RZAG60A / FDXM60F9
RZAG
|
DAIKIN | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.90 | 3.30 | -20° | 6.00 | 4.50 | |
|
RZAG60A / FNA60A9
RZAG
|
DAIKIN | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.90 | 3.30 | -20° | 6.00 | 4.50 | |
|
RXM60R / FHA60A9
RXM
|
DAIKIN | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.08 | 3.87 | 3.32 | -15° | 5.70 | 4.71 | |
|
RAV-GV801ATP-E/RAV-HM801BTP-E
DIC
|
TOSHIBA | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 4.00 | 3.00 | -15° | 6.70 | 4.80 | |
|
AOYG24KATA/ABYG24KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
ROG24KATA/RYG24KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOEG24KATA/ABEG24KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOEG24KATA/ABYG24KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOYG24KATA/ABYG24KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOYG24KATA/ARXG24KMLA
ARXG**K
|
FUJITSU | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
ROG24KATA/RDG24KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOHG24KATA/ARXG24KMLA
ARXG**K
|
GENERAL | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOEG24KATA/ARXG24KMLA
ARXG**K
|
FUJITSU | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.75 | -15° | 6.80 | 5.40 |