Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(3)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(1)
GSS
(0)
HAIER
(1)
HEC
(0)
HEIWA
(0)
HISENSE
(1)
HITACHI
(1)
IVT
(0)
Inventor
(3)
KAYSUN
(0)
LG
(0)
MIDEA
(1)
MITSUBISHI ELECTRIC
(14)
Mitsubishi Heavy Industries
(2)
NORD
(1)
Nobu
(0)
PANASONIC
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(1)
THERMOR
(0)
TOSHIBA
(3)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GM801ATP-E/RAV-HM801FT-E
DI
|
TOSHIBA | Floor standing | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.89 | 3.81 | 2.41 | -15° | 6.70 | 4.70 | |
|
GVH24AMXF-K6DNC7A
Floor-standing
|
GREE | Floor standing | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.39 | -10° | 7.20 | 5.60 | |
|
RZASG71MV1 / FVA71A
RZASG
|
DAIKIN | Floor standing | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 4.04 | 3.71 | -10° | 6.80 | 4.50 | |
|
FDC71VNP-W/FDF71VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.85 | 3.91 | 3.51 | -15° | 7.10 | 5.70 | |
|
FDC71VNP-W/FDF71VH1
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.85 | 3.91 | 3.51 | -15° | 7.10 | 5.70 | |
|
RAV-GM802ATW-E/RAV-HM801FT-E
DI
|
TOSHIBA | Floor standing | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.53 | 4.00 | 3.11 | -15° | 6.70 | 5.10 | |
|
U7RS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
SUZ-M71VA/SFZ-M71VA
S series
|
MITSUBISHI ELECTRIC | Floor standing | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA2/SFZ-M71VA2
S series
|
MITSUBISHI ELECTRIC | Floor standing | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.10 | 5.80 | |
|
SUZ-M60VA/MFZ-KT60VG
S series
|
MITSUBISHI ELECTRIC | Floor standing | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.21 | -10° | 6.10 | 4.60 | |
|
SUZ-M60VA2/MFZ-KT60VGK
S series
|
MITSUBISHI ELECTRIC | Floor standing | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.21 | -10° | 6.10 | 4.60 | |
|
SUZ-M71VA/PSA-M71KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.21 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA2/PSA-M71KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.21 | -10° | 7.10 | 5.80 | |
|
PUZ-ZM71VHA2/PSA-M71KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.25 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PSA-M71KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.25 | -20° | 7.10 | 4.80 | |
|
RZAG71NV1 / FVA71A
RZAG
|
DAIKIN | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.34 | 4.05 | 3.39 | -10° | 6.80 | 4.70 | |
|
RZAG71NY1 / FVA71A
RZAG
|
DAIKIN | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.34 | 4.05 | 3.39 | -10° | 6.80 | 4.70 | |
|
SUZ-M60VA/SFZ-M60VA
S series
|
MITSUBISHI ELECTRIC | Floor standing | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 6.10 | 4.60 | |
|
SUZ-M60VA2/SFZ-M60VA2
S series
|
MITSUBISHI ELECTRIC | Floor standing | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 6.10 | 4.60 | |
|
AP71DFMHRA/1U71WEMFRA
New Cabinet RAC
|
HAIER | Floor standing | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.00 | 3.70 | -10° | 7.20 | 5.50 | |
|
V7FSO-24/V7FSI-24
Floor Standing Cabinet R32
|
Inventor | Floor standing | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.00 | 3.70 | -10° | 7.20 | 5.50 | |
|
AUW71U4RJ7/AUF71UR4RCPA8
Super Inverter R32
|
HISENSE | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.71 | -10° | 7.00 | 5.50 | |
|
U7iRS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
AC100BXPDKH/AC100BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.30 | -20° | 10.00 | 5.30 | |
|
MFZ-KW60VG/MUFZ-KW60VGHZ
M series
|
MITSUBISHI ELECTRIC | Floor standing | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 3.45 | -25° | 6.10 | 4.80 | |
|
MUFZ-KW60VGHZ2/MFZ-KW60VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 3.45 | -25° | 6.10 | 4.80 | |
|
MFZ-KW50VG/MUFZ-KW50VGHZ
M series
|
MITSUBISHI ELECTRIC | Floor standing | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.20 | 3.75 | -25° | 5.00 | 4.50 | |
|
MUFZ-KW50VGHZ2/MFZ-KW50VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.20 | 3.70 | -25° | 5.00 | 4.50 | |
|
RAC-50FXE / RAF-50RXE
RAC-FXE
|
HITACHI | Floor standing | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.80 | -20° | 5.00 | 4.61 | |
|
MOX430UL-24HFN8-QRD0W/MFHA-24HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.75 | -10° | 7.10 | 5.40 | |
|
RAV-GP801ATW-E/RAV-HM801FT-E
SDI
|
TOSHIBA | Floor standing | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.43 | 4.43 | 3.38 | -27° | 7.10 | 5.10 | |
|
NB71MBAHRA/1N71WEAFRA-W
NORD - Mini Cassette
|
NORD | Mini cassette | — No score: too few class peers or too few declared metrics. Why? | 6.10 | 4.05 | 3.15 | -10° | 6.20 | 4.60 |