Filters · 1 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(23)
ATLANTIC
(9)
AUX
(21)
BOSCH
(24)
BRYANT
(1)
Buderus
(12)
CARRIER
(26)
CIAT
(7)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(2)
DAIKIN
(148)
EQUATION
(3)
FUJI ELECTRIC
(14)
FUJITSU
(37)
Fujitsu Atlantic
(17)
GENERAL
(18)
GREE
(23)
GSS
(1)
HAIER
(142)
HEC
(0)
HEIWA
(2)
HISENSE
(59)
HITACHI
(39)
IVT
(1)
Inventor
(32)
KAYSUN
(7)
LG
(72)
MIDEA
(157)
MITSUBISHI ELECTRIC
(103)
Mitsubishi Heavy Industries
(33)
NORD
(16)
Nobu
(2)
PANASONIC
(57)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(32)
THERMOR
(15)
TOSHIBA
(47)
Viessmann
(3)
Vulcano
(6)
WESTPOINT
(5)
YORK
(5)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
M3OG-21HFN8-Q-GR/MSAGAU-09HRFNX-QRD0GW-GR+MSAGBU-12HRFNX-QRD0GW-GR
M3OG-21HFN8-Q
|
MIDEA | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 6.10 | 5.70 | |
|
42QHA024D8S*/38QHA024D8S*
Wall mounted
|
CARRIER | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
42HF24JS8C-1/38HF24JS8C-1
Wall mounted
|
CIAT | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
WR070HJM8-1/AIR070HJM8-1
Wall mounted
|
RIELLO | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
42BRF024B8S*/38BRF024B8S*
Wall mounted
|
BRYANT | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
42QHF024D8S*/38QHF024D8S*
Wall mounted
|
CARRIER | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
COLI24R8SHF/COLI24R8SHC
Wall mounted
|
COLIBRI | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
Vitoclima 050-S IWAA050MFA070/Vitoclima 050-S OWAA050MFA070
Wall mounted
|
Viessmann | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
AL-H18/4DR3HB3(U) / AUCA-H18/4DR3HB2
Y-Cassette
|
AUX | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.28 | 4.50 | |
|
RXYL52M-T1B/FDCA52YB-B
Y-Cassette
|
AUX | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.28 | 4.50 | |
|
M2OE-18HFN8-Q/MSAGBU-09HRFN8-QRD1GW(GA)+MSAGBU-09HRFN8-QRD1GW(GA)
M2OE-18HFN8-Q
|
MIDEA | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
M2OE-18HFN8-Q/MSEPBU-09HRFN8-QRD6GW+MSEPBU-09HRFN8-QRD6GW
M2OE-18HFN8-Q
|
MIDEA | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
M2OE-18HFN8-Q/MSAGBU-09HRFN8-QRD1GW(GA)-HIWF+MSAGBU-09HRFN8-QRD1GW(GA)-HIWF
M2OE-18HFN8-Q
|
MIDEA | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
M2O-18N8/MAG1-09N8+MAG1-09N8
M2OE-18HFN8-Q
|
MIDEA | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
CL5000M 53/2 E / CL5000iU W 26 E + CL5000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
CL5000M 53/2 E / CL6001iU W 26 E + CL6001iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
UE-E3CM 53/2 / UI-E3CU M 26 + UI-E3CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
AC-5,3 MS / AC176i.3-2,6 W + AC176i.3-2,6 W
Logacool
|
Buderus | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
ZDAA-2050-09M25/HDHC-025N-09M25x2
ZDAA
|
AIRWELL | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
AB71S2SG1FA/1U71S2ST1FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.08 | 4.00 | 3.30 | -10° | 7.10 | 5.00 | |
|
ARXM71R / FCAG71B
ARXM
|
DAIKIN | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.87 | 4.00 | 3.38 | -15° | 6.80 | 4.50 | |
|
ARXM71A / FCAG71B
ARXM
|
DAIKIN | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.87 | 4.00 | 3.38 | -15° | 6.80 | 4.50 | |
|
M2OE-18HFN8-Q/MTIU-09HWFNX(GA)+MTIU-09HWFNX(GA)
M2OE-18HFN8-Q
|
MIDEA | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.30 | 4.60 | |
|
M2OE-18HFN8-Q/MTIU-09HWFNX-QRD0W(GA)+MTIU-09HWFNX-QRD0W(GA)
M2OE-18HFN8-Q
|
MIDEA | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.30 | 4.60 | |
|
CL5000M 53/2 E / CL5000iM D 26 E + CL5000iM D 26 E
Climate 5000 M
|
BOSCH | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.30 | 4.60 | |
|
AC-5,3 MS / AC166i-2,6 MS D + AC166i-2,6 MS D
Logacool
|
Buderus | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.30 | 4.60 | |
|
M2OE-18HFN8-Q-GR/MTIU-09HWFNX-QRD0W(GA)-GR+MTIU-09HWFNX-QRD0W(GA)-GR
M2OE-18HFN8-Q
|
MIDEA | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.30 | 4.60 | |
|
RPIL-2.0UNE1NH / RAS-2.0UNESNH1
Primairy R410 series
|
HITACHI | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.40 | -15° | 5.28 | 4.80 | |
|
AD50S2SM3FA/1U50S2SJ2FA-2
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.00 | 4.50 | |
|
UUC1 U40 / UM30F NA0
U4
|
LG | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.71 | -10° | 7.50 | 5.40 | |
|
AW-YXDL018-H91/AW-XDL018-N91
XDL
|
AIRWELL | Console | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.00 | 3.55 | -10° | 5.20 | 5.00 | |
|
YDAF-050R-09M25/XDLF-050N-09M25
XDLF
|
AIRWELL | Console | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.00 | 3.55 | -10° | 5.20 | 5.00 | |
|
GVH24AMXF-K6DNC7A
Floor-standing
|
GREE | Floor standing | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.39 | -10° | 7.20 | 5.60 | |
|
HDLS-070N-09M25/YDAS-070R-09M25
HDLS
|
AIRWELL | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 6.95 | 5.20 | |
|
GSX-IDU-024/GSX-ODU-024
GSX
|
GSS | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 6.95 | 5.20 | |
|
AS70BT2BW/CA70BT2BG
Easy Smart
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
AS70BT2EW/KE70BT2BG
Ultra Comfort
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
AS70BT2EW/KF70BT2BG
Expert Comfort
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
AS70BT2EW/KB70BT2BG
Wings Comfort
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
AS70BT2BW/KE70BT2BG
Ultra Comfort
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
AS70BT2BW/KF70BT2BG
Expert Comfort
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
AS70BT2BW/KB70BT2BG
Wings Comfort
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
AS70BT2BW/CF70BT2BG
Hi Comfort
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
CA70BT2BW/CA70BT2BG
Easy Smart
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
ATBT242RW/CBBT242RG
Halo
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
ATBT242RW/CDBT242RG
Pearl
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
AS70BT2BW/CG70BT2BG
eCool Smart
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
AS70BT2BW/KC70BT2BG
Clima
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
AS70BT2BW/KG70BT2BG
Appie Pie
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 | |
|
AS70BT2BW/KD70BT2BG
Easy Smart
|
HISENSE | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.30 | -10° | 6.30 | 5.40 |