Filters · 7 active
Manufacturer:
BOSCH
CIAT
Candy
Inventor
KAYSUN
SAMSUNG
AIRCLASS
(0)
AIRWELL
(10)
ATLANTIC
(6)
AUX
(18)
BRYANT
(0)
Buderus
(2)
CARRIER
(13)
COLIBRI
(0)
CONFORT AIR
(0)
DAIKIN
(298)
DE DIETRICH
(0)
EQUATION
(0)
FUJI ELECTRIC
(19)
FUJITSU
(49)
Fujitsu Atlantic
(21)
GENERAL
(25)
GREE
(13)
GSS
(0)
HAIER
(98)
HEC
(0)
HEIWA
(0)
HISENSE
(23)
HITACHI
(26)
IVT
(0)
LG
(6)
MIDEA
(59)
MITSUBISHI ELECTRIC
(129)
Mitsubishi Heavy Industries
(37)
NORD
(4)
Nobu
(0)
PANASONIC
(16)
PITSOS
(0)
RIELLO
(7)
Rotenso
(0)
THERMOR
(5)
TOSHIBA
(81)
Viessmann
(6)
Vulcano
(2)
WESTPOINT
(0)
XTRON
(0)
YORK
(5)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CL5000M 82/4 E / CL3000iU W 26 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 3.80 | 3.40 | -10° | 8.20 | 6.00 | |
|
AJ100TXJ5KH / AJ050TNAPKH / AJ050TNAPKH
FJM
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.51 | 3.83 | 3.63 | -10° | 8.56 | 7.70 | |
|
AJ100TXJ5KG / AR60F18C1AW / AR60F18C1AW
FJM
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.58 | 3.83 | 3.63 | -10° | 8.56 | 7.70 | |
|
CL5000M 105/4 / CL3000iU W 53 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.10 | -10° | 10.50 | 8.10 | |
|
U5MRSL32(4)-36/LN2UVI-18WFI+LN2UVI-18WFI
ODU + Wall Mounted
|
Inventor | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.10 | -10° | 10.50 | 8.10 | |
|
CL5000L 70 E / CL5000iU 4C 70 E
Climate 5000i L
|
BOSCH | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.00 | 6.00 | |
|
KUE-71 DVR13/KCIS-71 DR14
ZEN Cassette
|
KAYSUN | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.00 | 6.00 | |
|
U7RS-24/V7CI-24WiFiR
Cassette R32
|
Inventor | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.00 | 6.00 | |
|
CL5000L 105 E-3 / CL5000iL 4C 105 E
Climate 5000i L
|
BOSCH | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.68 | -10° | 10.50 | 8.00 | |
|
KUE-105 DTR13/KCIS-105 DR14
ZEN Cassette
|
KAYSUN | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.68 | -10° | 10.50 | 8.00 | |
|
42HK24VDS8C/38HU24VDS8C
Cassette
|
CIAT | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.05 | -10° | 7.04 | 6.00 | |
|
AC120RXADKG/AC120RN4DKG
CAC
|
SAMSUNG | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.18 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RN4DKG
CAC
|
SAMSUNG | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.26 | -20° | 12.00 | 6.50 | |
|
AC120RXADKG/AC120RN4PKG
CAC
|
SAMSUNG | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.26 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RN4PKG
CAC
|
SAMSUNG | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.26 | -20° | 12.00 | 6.50 | |
|
U5MRSL32(4)-36/AR5VI-18WiFi+AR5VI-18WiFi
ODU + Wall Mounted
|
Inventor | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.20 | -10° | 10.50 | 8.30 | |
|
KUE-71 DVR14/KCIS-71 DR14
ZEN Cassette R32
|
KAYSUN | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.01 | -10° | 7.10 | 6.20 | |
|
U7iRS-24/V7CI-24WiFiR
Cassette R32
|
Inventor | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.01 | -10° | 7.10 | 6.20 | |
|
CL5001L 70 E / CL5000iU 4C 70 E
Climate 5001 L
|
BOSCH | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.01 | -10° | 7.10 | 6.20 | |
|
42HK36VDS8C/38HU36VDT8C
Cassette
|
CIAT | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.61 | -10° | 10.50 | 8.00 | |
|
AC120RXADKG/AC120RNMDKG
CAC
|
SAMSUNG | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.42 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RNMDKG
CAC
|
SAMSUNG | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.48 | -20° | 12.00 | 6.50 | |
|
AC120RXADKG/AC120RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.45 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.47 | -20° | 12.00 | 6.50 | |
|
AC140RXADKG / AC140RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -20° | 13.40 | 8.40 | |
|
42HK36VDS8C/38HU36VDS8C
Cassette
|
CIAT | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 3.55 | -10° | 10.50 | 8.20 | |
|
AC140RXADKG / AC140RN4PKG
CAC
|
SAMSUNG | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.35 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RN4PKG
CAC
|
SAMSUNG | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.41 | -20° | 13.40 | 8.40 | |
|
CL5000L 88 E / CL5000iL 4C 88 E
Climate 5000i L
|
BOSCH | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
KUE-90 DVR13/KCIS-90 DR14
ZEN Cassette
|
KAYSUN | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
U7RS-30/V7CI-30WiFiR
Cassette R32
|
Inventor | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
KUE-90 DVR14/KCIS-90 DR14
ZEN Cassette R32
|
KAYSUN | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
U7iRS-30/V7CI-30WiFiR
Cassette R32
|
Inventor | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
CL5001L 88 E / CL5000iL 4C 88 E
Climate 5001 L
|
BOSCH | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
AC140RXADKG / AC140RNMDKG
CAC
|
SAMSUNG | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.00 | 3.34 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RNMDKG
CAC
|
SAMSUNG | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.00 | 3.44 | -20° | 13.40 | 8.40 | |
|
CL5000L 105 E / CL5000iL D 105 E
Climate 5000i L
|
BOSCH | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
KUE-105 DVR13/KPD-105 DR14
ZEN Duct
|
KAYSUN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
KUE-105 DVR13/KPD-105V DR14
ZEN Duct
|
KAYSUN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
U7RS-36/V7DI-36WiFiR
Ducted R32
|
Inventor | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
42HY36VDS8C/38HU36VDS8C
Ducted
|
CIAT | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.69 | -10° | 10.50 | 8.40 | |
|
42HK30VDS8C/38HU30VD8SC
Cassette
|
CIAT | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.00 | -10° | 8.80 | 7.50 | |
|
CL5000L 88 E / CL5000iL D 88 E
Climate 5000i L
|
BOSCH | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
KUE-90 DVR13/KPD-90 DR14
ZEN Duct
|
KAYSUN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
AC100BXAPKG/AC100BNTPKG
CAC HEE
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.13 | -25° | 9.50 | 6.50 | |
|
AC100BXAPNG/AC100BNTPKG
CAC HEE
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.13 | -25° | 9.50 | 6.50 | |
|
AC140RXADKG / AC140RN4DKG
CAC
|
SAMSUNG | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.16 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RN4DKG
CAC
|
SAMSUNG | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.25 | -20° | 13.40 | 8.40 | |
|
42HY30VDS8C/38HU30VDS8C
Ducted
|
CIAT | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.00 | 4.04 | -10° | 8.75 | 8.00 |