Filters · 4 active
Manufacturer:
BOSCH
CONFORT AIR
HITACHI
AIRCLASS
(0)
AIRWELL
(10)
ATLANTIC
(6)
AUX
(18)
BRYANT
(0)
Buderus
(2)
CARRIER
(13)
CIAT
(6)
COLIBRI
(0)
Candy
(0)
DAIKIN
(298)
EQUATION
(0)
FUJI ELECTRIC
(19)
FUJITSU
(49)
Fujitsu Atlantic
(21)
GENERAL
(25)
GREE
(12)
GSS
(0)
HAIER
(98)
HEC
(0)
HEIWA
(0)
HISENSE
(14)
IVT
(0)
Inventor
(9)
KAYSUN
(10)
LG
(6)
MIDEA
(59)
MITSUBISHI ELECTRIC
(129)
Mitsubishi Heavy Industries
(37)
NORD
(4)
Nobu
(0)
PANASONIC
(16)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(27)
THERMOR
(5)
TOSHIBA
(81)
Viessmann
(6)
Vulcano
(2)
WESTPOINT
(0)
YORK
(5)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CL5000M 82/4 E / CL3000iU W 26 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 3.80 | 3.40 | -10° | 8.20 | 6.00 | |
|
RPFC-4.0UFE1NH/RAS-4.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.87 | 3.82 | 2.88 | -15° | 9.80 | 7.90 | |
|
CL5000M 105/4 / CL3000iU W 53 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.10 | -10° | 10.50 | 8.10 | |
|
CL5000L 70 E / CL5000iU 4C 70 E
Climate 5000i L
|
BOSCH | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.00 | 6.00 | |
|
RAS-4HNC2E / RPK-4.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.83 | 2.87 | -20° | 10.00 | 7.40 | |
|
RAS-4HRC2E / RPK-4.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.18 | 3.80 | 2.82 | -20° | 10.00 | 7.40 | |
|
CL5000L 105 E-3 / CL5000iL 4C 105 E
Climate 5000i L
|
BOSCH | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.68 | -10° | 10.50 | 8.00 | |
|
RCI-4.0UFE1NH/RAS-4.0UFESNH1
Primairy R32 series
|
HITACHI | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.92 | 3.20 | -15° | 10.10 | 8.20 | |
|
RAS-4HVNC2E / RPK-4.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.17 | 3.83 | 2.87 | -20° | 10.00 | 7.40 | |
|
RPFC-3.0UFE1NH/RAS-3.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 4.01 | 3.55 | -15° | 6.50 | 6.00 | |
|
RAS-4HVRC2E / RPK-4.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.45 | 3.80 | 2.82 | -20° | 10.00 | 7.40 | |
|
CL5001L 70 E / CL5000iU 4C 70 E
Climate 5001 L
|
BOSCH | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.01 | -10° | 7.10 | 6.20 | |
|
RPIH-4.0UFE1NH/RAS-4.0UFESNH1
Primairy R32 series
|
HITACHI | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.92 | 3.00 | -15° | 10.10 | 8.20 | |
|
RCI-3.5UFE1NH/RAS-3.5UFESNH1
Primairy R32 series
|
HITACHI | Cassette | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 4.00 | -15° | 8.70 | 7.20 | |
|
RPIH-3.5UFE1NH/RAS-3.5UFESNH1
Primairy R32 series
|
HITACHI | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -15° | 8.50 | 6.50 | |
|
CL5000L 88 E / CL5000iL 4C 88 E
Climate 5000i L
|
BOSCH | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
CL5001L 88 E / CL5000iL 4C 88 E
Climate 5001 L
|
BOSCH | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
RPIL-3.0UFE1NH/RAS-3.0UFESNH1
Primairy R32 series
|
HITACHI | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.05 | 3.74 | -15° | 6.90 | 6.00 | |
|
CL5000L 105 E / CL5000iL D 105 E
Climate 5000i L
|
BOSCH | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
RPIH-3.0UFE1NH/RAS-3.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling suspended | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.00 | 3.86 | -15° | 7.30 | 6.00 | |
|
RPFC-3.5UFE1NH/RAS-3.5UFESNH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.78 | -15° | 8.60 | 6.50 | |
|
CL5000L 88 E / CL5000iL D 88 E
Climate 5000i L
|
BOSCH | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
RAS-3HVRC3 / RPI-3.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.82 | 3.92 | 3.84 | -25° | 7.10 | 6.00 | |
|
CL5001L 105 E / CL5001iL D 105 E
Climate 5001 L
|
BOSCH | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
RAS-3HVRC3 / RPC-3.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.09 | 3.73 | -25° | 7.10 | 6.00 | |
|
RAM-Y85N5HAE / RAK-XJ35RHBE / RAK-XJ50RHBE
RAM-YNHAE
|
HITACHI | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 3.90 | -10° | 8.50 | 6.80 | |
|
RAM-Y85N5HAE / RAK-XJ35RHBE / RAK-XJ50RHBE
RAM-YNHAE
|
HITACHI | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 3.90 | -10° | 8.50 | 6.80 | |
|
RAM-G85N5HCE / RAK-XJ35RHBE / RAK-XJ50RHBE
RAM-GNHCE
|
HITACHI | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.30 | 3.90 | -10° | 8.50 | 6.80 | |
|
RCI-3.0UFE1NH/RAS-3.0UFESNH1
Primairy R32 series
|
HITACHI | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.73 | 4.33 | 4.07 | -15° | 7.00 | 6.00 | |
|
RAS-3HVRC3 / RCI-3.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.41 | 4.20 | 4.35 | -25° | 7.10 | 6.00 | |
|
RAC-70NPD / RAK-70PPD
RAC-NPE(D)
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 4.41 | 3.81 | -15° | 7.00 | 6.40 | |
|
RAM-90NYP5E / RAK-35RXE / RAK-50RXE
RAM-NYPE
|
HITACHI | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.31 | 3.90 | -15° | 8.50 | 7.10 | |
|
CL5001L 88 E / CL5001iL D 88 E
Climate 5001 L
|
BOSCH | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
RAM-G85N5HAE / RAK-XJ35RHAE / RAK-XJ50RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.95 | 4.30 | 3.90 | -15° | 8.50 | 6.80 | |
|
RAM-G85N5HBE / RAK-XJ35RHAE / RAK-XJ50RHAE
RAM-GNHBE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.95 | 4.30 | 3.90 | -15° | 8.50 | 6.80 | |
|
RAM-70NYP4E / RAK-35RXE / RAK-35RXE
RAM-NYPE
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.42 | 4.61 | 4.20 | -15° | 7.00 | 6.00 | |
|
RAM-53NYP3E / RAK-18QXE / RAK-35RXE
RAM-NYPE
|
HITACHI | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.61 | 4.61 | 4.20 | -15° | 5.30 | 6.00 |