Filters · 4 active
Manufacturer:
Inventor
PANASONIC
THERMOR
AIRCLASS
(0)
AIRWELL
(10)
ATLANTIC
(6)
AUX
(18)
BOSCH
(11)
BRYANT
(0)
Buderus
(2)
CARRIER
(13)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(298)
EQUATION
(0)
FUJI ELECTRIC
(19)
FUJITSU
(49)
Fujitsu Atlantic
(21)
GENERAL
(25)
GREE
(12)
GSS
(0)
HAIER
(98)
HEC
(0)
HEIWA
(0)
HISENSE
(14)
HITACHI
(26)
IVT
(0)
KAYSUN
(10)
LG
(6)
MIDEA
(59)
MITSUBISHI ELECTRIC
(129)
Mitsubishi Heavy Industries
(37)
NORD
(4)
Nobu
(0)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(27)
TOSHIBA
(81)
Viessmann
(6)
Vulcano
(2)
WESTPOINT
(0)
YORK
(5)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
IM52-NS + IM35-NS/E4U85LV2-NG-NS
MULTI-NISEKO MURALE
|
THERMOR | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 2.90 | -10° | 7.30 | 6.30 | |
|
IM52-NS + IM70-NS/E5U10LV2-NG-NS
MULTI-NISEKO MURALE
|
THERMOR | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.00 | -10° | 8.20 | 7.30 | |
|
IM52V2-NG + IM35V2-NG/E4U85LV2-NG-NS
MULTI-NAGANO MURALE PURE
|
THERMOR | Wall mounted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.00 | -10° | 7.50 | 6.50 | |
|
IM52V2-NG + IM70V2-NG/E5U10LV2-NG-NS
MULTI-NAGANO MURALE PURE
|
THERMOR | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.30 | -10° | 8.50 | 7.50 | |
|
U5MRSL32(4)-36/LN2UVI-18WFI+LN2UVI-18WFI
ODU + Wall Mounted
|
Inventor | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.10 | -10° | 10.50 | 8.10 | |
|
U7RS-24/V7CI-24WiFiR
Cassette R32
|
Inventor | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.00 | 6.00 | |
|
NAGANO GAINABLE MP IG95MP-NG / E1U90LV2-NG
NAGANO GAINABLE MOYENNE PRESSION
|
THERMOR | Ducted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.49 | -10° | 9.50 | 7.20 | |
|
CU-5Z90TBE/CS-Z35ZKEW/CS-TZ71ZKEW
2023
|
PANASONIC | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.90 | -15° | 9.00 | 6.50 | |
|
U5MRSL32(4)-36/AR5VI-18WiFi+AR5VI-18WiFi
ODU + Wall Mounted
|
Inventor | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.20 | -10° | 10.50 | 8.30 | |
|
U7iRS-24/V7CI-24WiFiR
Cassette R32
|
Inventor | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.01 | -10° | 7.10 | 6.20 | |
|
U-100PZH4E8 / S-6010PK3E
2023
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.88 | -20° | 9.50 | 8.00 | |
|
U-100PZH4E5 / S-6010PK3E
2023
|
PANASONIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 3.90 | 3.88 | -20° | 9.50 | 8.00 | |
|
U-100PZ3E8 / S-1014PF3E
2021
|
PANASONIC | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 3.90 | 4.09 | -15° | 9.50 | 7.80 | |
|
CU-4Z80CBE/CS-Z71CKEW/CS-Z71CKEW
2025
|
PANASONIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 4.33 | -15° | 8.00 | 6.80 | |
|
U7RS-30/V7CI-30WiFiR
Cassette R32
|
Inventor | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
U-100PZ3E5 / S-1014PF3E
2021
|
PANASONIC | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 3.90 | 4.09 | -15° | 9.50 | 7.80 | |
|
U7iRS-30/V7CI-30WiFiR
Cassette R32
|
Inventor | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
U7RS-36/V7DI-36WiFiR
Ducted R32
|
Inventor | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
U-100PZH4E5/S-5010PK4E/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -20° | 9.50 | 8.00 | |
|
U-100PZH4E8/S-5010PK4E/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -20° | 9.50 | 8.00 | |
|
U-100PZH4E5/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -20° | 9.50 | 8.00 | |
|
U-100PZH4E8/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -20° | 9.50 | 8.00 | |
|
U7RS-36/V7iDI-36WiFiR
Ducted R32
|
Inventor | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
U7iRS-30/V7iDI-30WiFiR
Ducted R32
|
Inventor | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
U-100PZH4E8 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.50 | 4.00 | -20° | 9.50 | 7.80 | |
|
U-100PZH4E5 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.50 | 4.00 | -20° | 9.50 | 7.80 | |
|
U-100PZH4E5 / S-1014PF3E
2023
|
PANASONIC | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.30 | 3.88 | -20° | 9.50 | 7.80 | |
|
U-100PZH4E8 / S-1014PF3E
2023
|
PANASONIC | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.30 | 3.88 | -20° | 9.50 | 7.80 | |
|
U-100PZH4E5 / S-1014PU3E
2023
|
PANASONIC | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.90 | 5.00 | -20° | 9.50 | 8.00 | |
|
U-100PZH4E8 / S-1014PU3E
2023
|
PANASONIC | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.90 | 5.00 | -20° | 9.50 | 8.00 |