Filters · 4 active
Manufacturer:
BOSCH
PANASONIC
WESTPOINT
AIRCLASS
(0)
AIRWELL
(10)
ATLANTIC
(6)
AUX
(18)
BRYANT
(0)
Buderus
(2)
CARRIER
(13)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(298)
EQUATION
(0)
FUJI ELECTRIC
(19)
FUJITSU
(49)
Fujitsu Atlantic
(21)
GENERAL
(25)
GREE
(12)
GSS
(0)
HAIER
(98)
HEC
(0)
HEIWA
(0)
HISENSE
(14)
HITACHI
(26)
IVT
(0)
Inventor
(9)
KAYSUN
(10)
LG
(6)
MIDEA
(59)
MITSUBISHI ELECTRIC
(129)
Mitsubishi Heavy Industries
(37)
NORD
(4)
Nobu
(0)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(27)
THERMOR
(5)
TOSHIBA
(81)
Viessmann
(6)
Vulcano
(2)
YORK
(5)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CL5000M 82/4 E / CL3000iU W 26 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 3.80 | 3.40 | -10° | 8.20 | 6.00 | |
|
CL5000M 105/4 / CL3000iU W 53 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.10 | -10° | 10.50 | 8.10 | |
|
CL5000L 70 E / CL5000iU 4C 70 E
Climate 5000i L
|
BOSCH | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.00 | 6.00 | |
|
CL5000L 105 E-3 / CL5000iL 4C 105 E
Climate 5000i L
|
BOSCH | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.68 | -10° | 10.50 | 8.00 | |
|
CU-5Z90TBE/CS-Z35ZKEW/CS-TZ71ZKEW
2023
|
PANASONIC | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.90 | -15° | 9.00 | 6.50 | |
|
CL5001L 70 E / CL5000iU 4C 70 E
Climate 5001 L
|
BOSCH | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.01 | -10° | 7.10 | 6.20 | |
|
U-100PZH4E8 / S-6010PK3E
2023
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.88 | -20° | 9.50 | 8.00 | |
|
U-100PZH4E5 / S-6010PK3E
2023
|
PANASONIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 3.90 | 3.88 | -20° | 9.50 | 8.00 | |
|
U-100PZ3E8 / S-1014PF3E
2021
|
PANASONIC | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 3.90 | 4.09 | -15° | 9.50 | 7.80 | |
|
CU-4Z80CBE/CS-Z71CKEW/CS-Z71CKEW
2025
|
PANASONIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 4.33 | -15° | 8.00 | 6.80 | |
|
CL5000L 88 E / CL5000iL 4C 88 E
Climate 5000i L
|
BOSCH | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
U-100PZ3E5 / S-1014PF3E
2021
|
PANASONIC | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 3.90 | 4.09 | -15° | 9.50 | 7.80 | |
|
CL5001L 88 E / CL5000iL 4C 88 E
Climate 5001 L
|
BOSCH | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
CL5000L 105 E / CL5000iL D 105 E
Climate 5000i L
|
BOSCH | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
CL5000L 88 E / CL5000iL D 88 E
Climate 5000i L
|
BOSCH | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
U-100PZH4E5/S-5010PK4E/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -20° | 9.50 | 8.00 | |
|
U-100PZH4E8/S-5010PK4E/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -20° | 9.50 | 8.00 | |
|
U-100PZH4E5/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -20° | 9.50 | 8.00 | |
|
U-100PZH4E8/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -20° | 9.50 | 8.00 | |
|
CL5001L 105 E / CL5001iL D 105 E
Climate 5001 L
|
BOSCH | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
CL5001L 88 E / CL5001iL D 88 E
Climate 5001 L
|
BOSCH | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
U-100PZH4E8 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.50 | 4.00 | -20° | 9.50 | 7.80 | |
|
U-100PZH4E5 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.50 | 4.00 | -20° | 9.50 | 7.80 | |
|
U-100PZH4E5 / S-1014PF3E
2023
|
PANASONIC | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.30 | 3.88 | -20° | 9.50 | 7.80 | |
|
U-100PZH4E8 / S-1014PF3E
2023
|
PANASONIC | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.30 | 3.88 | -20° | 9.50 | 7.80 | |
|
U-100PZH4E5 / S-1014PU3E
2023
|
PANASONIC | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.90 | 5.00 | -20° | 9.50 | 8.00 | |
|
U-100PZH4E8 / S-1014PU3E
2023
|
PANASONIC | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.90 | 5.00 | -20° | 9.50 | 8.00 |