Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(7)
ATLANTIC
(0)
AUX
(18)
BOSCH
(6)
BRYANT
(0)
Buderus
(1)
CARRIER
(8)
CIAT
(2)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(133)
EQUATION
(0)
FUJI ELECTRIC
(16)
FUJITSU
(45)
Fujitsu Atlantic
(19)
GENERAL
(22)
GREE
(12)
GSS
(0)
HAIER
(43)
HEC
(0)
HEIWA
(0)
HISENSE
(13)
HITACHI
(18)
IVT
(0)
Inventor
(4)
KAYSUN
(5)
LG
(3)
MIDEA
(37)
MITSUBISHI ELECTRIC
(123)
Mitsubishi Heavy Industries
(33)
NORD
(4)
Nobu
(0)
PANASONIC
(15)
RIELLO
(2)
Rotenso
(0)
SAMSUNG
(11)
THERMOR
(0)
TOSHIBA
(47)
Viessmann
(3)
Vulcano
(1)
WESTPOINT
(0)
YORK
(2)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AZAS100MV1 / FCAG100B
AZAS
|
DAIKIN | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.67 | 3.85 | 3.71 | -10° | 9.50 | 6.00 | |
|
AZAS100MY1 / FCAG100B
AZAS
|
DAIKIN | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.67 | 3.85 | 3.71 | -10° | 9.50 | 6.00 | |
|
RZASG100MV1 / FBA50A9 / FBA50A9
RZASG
|
DAIKIN | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.38 | 3.80 | 3.80 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FBA50A9 / FBA50A9
RZASG
|
DAIKIN | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.38 | 3.80 | 3.80 | -10° | 9.50 | 6.00 | |
|
RZASG100MV / FBA50A9 / FBA50A9
RZASG
|
DAIKIN | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.38 | 3.80 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FBA50A9 / FBA50A9
RZASG
|
DAIKIN | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.38 | 3.80 | -10° | 9.50 | 6.00 | ||
|
M4OE-28HFN8-Q/MSAFBU-12HRFN8-QRD1GW+MSAFCU-18HRFNX-QRD0GW
M4OE-28HFN8-Q
|
MIDEA | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.71 | -10° | 8.20 | 6.20 | |
|
M4OE-28HFN8-Q(H)/ACE-12HRFN8 IN+ACE-18HRFN8 IN
M4OE-28HFN8-Q
|
MIDEA | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.71 | -10° | 8.20 | 6.20 | |
|
AZAS100MV1 / ADEA100A
AZAS
|
DAIKIN | Ducted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.13 | 3.81 | 4.63 | -10° | 9.50 | 6.00 | |
|
AZAS100MV1 / FBA100A
AZAS
|
DAIKIN | Ducted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.81 | 4.77 | -10° | 9.50 | 6.00 | |
|
AZAS100MY1 / FBA100A
AZAS
|
DAIKIN | Ducted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.81 | 4.77 | -10° | 9.50 | 6.00 | |
|
5U90S2SSS5FA/AS71S2SF1FA-MW3+AS50S2SF1FA-MW3
Super Match Multi
|
HAIER | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.50 | -10° | 8.00 | 7.00 | |
|
5U90S2SS5FA/AS50S2SJ1FA-3+AS50S2SJ1FA-3
Super Match Multi
|
HAIER | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.50 | -10° | 8.00 | 7.00 | |
|
5U90S2SS5FA/AS50XCAHRA+AS50XCAHRA
Super Match Multi
|
HAIER | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.50 | -10° | 8.00 | 7.00 | |
|
5U90S2SS5FA/AS71S2SF2FA-3+AS50S2SF2FA-3
Super Match Multi
|
HAIER | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.50 | -10° | 8.00 | 7.00 | |
|
M4OE-28HFN8-Q/MSAGAU-09HRFNX-QRD0GW+MSAGCU-18HRFNX-QRD0GW
M4OE-28HFN8-Q
|
MIDEA | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 3.80 | 3.40 | -10° | 8.20 | 6.00 | |
|
CL5000M 82/4 E / CL3000iU W 26 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 3.80 | 3.40 | -10° | 8.20 | 6.00 | |
|
UE-E3CM 82/4 / UI-L2CU M 26 + UI-L2CU M 53
Easy Cool M
|
Vulcano | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 3.80 | 3.40 | -10° | 8.20 | 6.00 | |
|
AC-8,2 MS / AC166i.2-2,6 W + AC166i.2-5,3 W
Logacool
|
Buderus | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 3.80 | 3.40 | -10° | 8.20 | 6.00 | |
|
M4OE-28HFN8-Q-GR/MSAGAU-09HRFNX-QRD0GW-GR+MSAGCU-18HRFNX-QRD0GW-GR
M4OE-28HFN8-Q
|
MIDEA | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 3.80 | 3.40 | -10° | 8.20 | 6.00 | |
|
AJ100TXJ5KH / AJ050TNAPKH / AJ050TNAPKH
FJM
|
SAMSUNG | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.51 | 3.83 | 3.63 | -10° | 8.56 | 7.70 | |
|
AJ100TXJ5KG / AR60F18C1AW / AR60F18C1AW
FJM
|
SAMSUNG | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.58 | 3.83 | 3.63 | -10° | 8.56 | 7.70 | |
|
AZAS100MY / ADEA100A
AZAS
|
DAIKIN | Ducted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.55 | 3.81 | -10° | 9.50 | 6.00 | ||
|
AZAS100MV / ADEA100A
AZAS
|
DAIKIN | Ducted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.55 | 3.81 | -10° | 9.50 | 6.00 | ||
|
AZAS100MY / FHA100A
AZAS
|
DAIKIN | Ceiling suspended | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.87 | -10° | 9.50 | 6.00 | ||
|
AZAS100MV / FHA100A
AZAS
|
DAIKIN | Ceiling suspended | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.87 | -10° | 9.50 | 6.00 | ||
|
AZAS100MV / FCAG100B
AZAS
|
DAIKIN | Cassette | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.12 | 3.85 | -10° | 9.50 | 6.00 | ||
|
AZAS100MY / FCAG100B
AZAS
|
DAIKIN | Cassette | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.12 | 3.85 | -10° | 9.50 | 6.00 | ||
|
AZAS100MV / FBA100A
AZAS
|
DAIKIN | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.67 | 3.81 | -10° | 9.50 | 6.00 | ||
|
AZAS100MY / FBA100A
AZAS
|
DAIKIN | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.67 | 3.81 | -10° | 9.50 | 6.00 | ||
|
RAV-GV1101ATP-E/RAV-HM1101BTP-E
DIC
|
TOSHIBA | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.33 | -15° | 9.50 | 7.60 | |
|
ABH105H1ERG/1U105S2SS1FB
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 4.00 | 3.50 | -10° | 9.20 | 6.00 | |
|
AB105S2SR1FA(H)/1U105S2SS1FB
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 4.00 | 3.50 | -10° | 9.20 | 6.00 | |
|
RZASG100MV1 / FBA100A
RZASG
|
DAIKIN | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.85 | 4.77 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FBA100A
RZASG
|
DAIKIN | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.85 | 4.77 | -10° | 9.50 | 6.00 | |
|
RZASG100MV / FBA100A
RZASG
|
DAIKIN | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.85 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FBA100A
RZASG
|
DAIKIN | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.85 | -10° | 9.50 | 6.00 | ||
|
AB125S2SR1FA(H)/1U125S2SN3FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.93 | 3.50 | 12.50 | 8.30 | ||
|
AB125S2SR1FA(H)/1U125S2SN3FB
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.93 | 3.50 | 12.50 | 8.30 | ||
|
RZASG100MV1 / FHA50A9 / FHA50A9
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.92 | 3.92 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FHA50A9 / FHA50A9
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.92 | 3.92 | -10° | 9.50 | 6.00 | |
|
RZASG100MY / FHA50A9 / FHA50A9
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.92 | -10° | 9.50 | 6.00 | ||
|
RZASG100MV / FHA50A9 / FHA50A9
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.92 | -10° | 9.50 | 6.00 | ||
|
RZASG100MV1 / FHA100A
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.91 | 4.81 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FHA100A
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.91 | 4.81 | -10° | 9.50 | 6.00 | |
|
RZASG100MY / FHA100A
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.91 | -10° | 9.50 | 6.00 | ||
|
RZASG100MV / FHA100A
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.91 | -10° | 9.50 | 6.00 | ||
|
M4OB-36HFN8-Q/MSAFCU-18HRFNX-QRD0GW+MSAFCU-18HRFNX-QRD0GW
M4OB-36HFN8-Q
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.35 | -10° | 10.30 | 8.40 | |
|
ZDAA-4090-09M25/HDLA-050N-09M25x2
ZDAA
|
AIRWELL | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.35 | -10° | 10.30 | 8.40 | |
|
M4OB-36HFN8-Q(H)/ACE-18HRFN8 IN+ACE-18HRFN8 IN
M4OB-36HFN8-Q
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.35 | -10° | 10.30 | 8.40 |