Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(1)
BRYANT
(0)
Buderus
(0)
CARRIER
(1)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(60)
EQUATION
(0)
FUJI ELECTRIC
(2)
FUJITSU
(9)
Fujitsu Atlantic
(3)
GENERAL
(6)
GREE
(1)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(10)
HITACHI
(6)
IVT
(0)
Inventor
(0)
KAYSUN
(1)
LG
(1)
MIDEA
(5)
MITSUBISHI ELECTRIC
(72)
Mitsubishi Heavy Industries
(19)
NORD
(0)
Nobu
(0)
PANASONIC
(8)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(5)
THERMOR
(0)
TOSHIBA
(13)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(1)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC100VSX/FDUM50VH/FDUM50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.11 | 3.87 | 3.71 | -20° | 10.00 | 8.20 | |
|
FDC100VNX/FDUM50VH/FDUM50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 3.88 | 3.71 | -20° | 10.00 | 8.20 | |
|
RZASG100MV1 / FCAG50B / FCAG50B
RZASG
|
DAIKIN | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 3.90 | 3.90 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FCAG50B / FCAG50B
RZASG
|
DAIKIN | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 3.90 | 3.90 | -10° | 9.50 | 6.00 | |
|
RZASG100MV / FCAG50B / FCAG50B
RZASG
|
DAIKIN | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 3.90 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FCAG50B / FCAG50B
RZASG
|
DAIKIN | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 3.90 | -10° | 9.50 | 6.00 | ||
|
MU4R27 U42 / MJ09PC NSJ0 / MJ18PC NSK0
MU
|
LG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.70 | 3.80 | 3.60 | -10° | 6.80 | 6.70 | |
|
RAV-GM1102AT8W-E/RAV-HM1101BTP-E
DI 3ph
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 3.92 | 3.90 | -15° | 9.50 | 8.40 | |
|
GWHD(21)NK6OO GWH09AGCXB-K6DNA1G/I+GWH12AGCXD-K6DNA1D/I
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.00 | 3.60 | -10° | 6.10 | 6.10 | |
|
RAV-GM1102AT8W-E/RAV-HM1101FT-E
DI 3ph
|
TOSHIBA | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.92 | 3.64 | -15° | 9.50 | 8.30 | |
|
U-100PZ3E8 / S-1014PF3E
2021
|
PANASONIC | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 3.90 | 4.09 | -15° | 9.50 | 7.80 | |
|
RAV-GM1102ATW-E/RAV-HM1101FT-E
DI
|
TOSHIBA | Floor standing | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.22 | 3.92 | 3.61 | -15° | 9.50 | 8.30 | |
|
U-100PZ3E5 / S-1014PF3E
2021
|
PANASONIC | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 3.90 | 4.09 | -15° | 9.50 | 7.80 | |
|
PUZ-M100YKA2/PSA-M100KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.00 | 3.45 | -15° | 9.40 | 8.00 | |
|
PUZ-M100VKA2/PSA-M100KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.00 | 3.45 | -15° | 9.40 | 8.00 | |
|
PUZ-M100VKA3/PSA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.00 | 3.45 | -15° | 9.40 | 8.00 | |
|
PUZ-M100YKA3/PSA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.00 | 3.45 | -15° | 9.40 | 8.00 | |
|
PUZ-ZM100YDA/PKA-M50LA2/PKA-M50LA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.61 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PKA-M50LA3/PKA-M50LA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.61 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PKA-M50LAL3/PKA-M50LAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.61 | -20° | 9.50 | 7.80 | |
|
RZASG100MV1 / FDXM50F9 / FDXM50F9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | 3.93 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FDXM50F9 / FDXM50F9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | 3.93 | -10° | 9.50 | 6.00 | |
|
RZASG100MV1 / FNA50A9 / FNA50A9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | 3.93 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FNA50A9 / FNA50A9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | 3.93 | -10° | 9.50 | 6.00 | |
|
RZASG100MV / FNA50A9 / FNA50A9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | -10° | 9.50 | 6.00 | ||
|
RZASG100MV / FDXM50F9 / FDXM50F9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FNA50A9 / FNA50A9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FDXM50F9 / FDXM50F9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | -10° | 9.50 | 6.00 | ||
|
RPIH-3.0UFE1NH/RAS-3.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling suspended | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.00 | 3.86 | -15° | 7.30 | 6.00 | |
|
MXZ-2E53VAHZ/MSZ-EF18VE3/MSZ-EF35VE3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 4.71 | -25° | 5.30 | 6.40 | |
|
PUZ-ZM100YKA2/PKA-M50LA2/PKA-M50LA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 1.90 | -20° | 9.50 | 7.80 | |
|
RZAG100NV1 / FFA50A9 / FFA50A9
RZAG
|
DAIKIN | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.03 | 4.17 | 4.17 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FFA50A9 / FFA50A9
RZAG
|
DAIKIN | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.03 | 4.17 | 4.17 | -10° | 9.50 | 7.80 | |
|
AOYG24KBTB/AUXG24KRLB
AUY**K
|
FUJITSU | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
AOHG24KBTB/AUXG24KRLB
AUH**K
|
GENERAL | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
ROG24KBTB/RCG24KRLB
RC**K
|
FUJI ELECTRIC | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
AOEG24KBTB/AUXG24KRLB
AUXG**K
|
FUJITSU | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/AUXG24KRLB
AUY**K
|
Fujitsu Atlantic | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
MXZ-2F53VFHZ2/MSZ-LN18VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
MXZ-2F53VFHZ3/MSZ-LN18VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
PUZ-ZM100VKA2/PKA-M50LA2/PKA-M50LA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 1.90 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA/PKA-M50LA2/PKA-M50LA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.61 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PKA-M50LA3/PKA-M50LA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.61 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PKA-M50LAL3/PKA-M50LAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.61 | -20° | 9.50 | 7.80 | |
|
MOD30U-30HFN8-QRD0W(GA)/MTI-30HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
MOD30U-30HFN8-Q(GA)/MTI-30HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
CL5000L 88 E / CL5000iL D 88 E
Climate 5000i L
|
BOSCH | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
MOD30U-30HFN8-QRD0W(GA)/MTI-30HWFNX-QRD0W(GA)-X
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
MO-30N8-Q/MTI-30HNX
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
KUE-90 DVR13/KPD-90 DR14
ZEN Duct
|
KAYSUN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 |