Filters · 5 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(20)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(3)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(1)
HITACHI
(3)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(0)
MIDEA
(2)
MITSUBISHI ELECTRIC
(8)
Mitsubishi Heavy Industries
(6)
NORD
(0)
Nobu
(0)
PANASONIC
(0)
RIELLO
(1)
Rotenso
(0)
SAMSUNG
(1)
THERMOR
(0)
TOSHIBA
(11)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AZAS125MV / FVA125A
AZAS
|
DAIKIN | Floor standing | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.30 | 3.56 | 3.75 | 12.10 | 6.00 | ||
|
AZAS125MY / FVA125A
AZAS
|
DAIKIN | Floor standing | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.30 | 3.56 | 12.10 | 6.00 | |||
|
RZASG125MV1 / FVA125A
RZASG
|
DAIKIN | Floor standing | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.52 | 3.64 | 3.71 | 12.10 | 6.00 | ||
|
RZASG125MY1 / FVA125A
RZASG
|
DAIKIN | Floor standing | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.52 | 3.64 | 3.71 | 12.10 | 6.00 | ||
|
RZASG125MY / FVA125A
RZASG
|
DAIKIN | Floor standing | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.52 | 3.64 | 12.10 | 6.00 | |||
|
RZASG125MV / FVA125A
RZASG
|
DAIKIN | Floor standing | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.52 | 3.64 | 12.10 | 6.00 | |||
|
RAV-GM1602AT8W-E/RAV-HM1601FT-E
DI 3ph
|
TOSHIBA | Floor standing | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.15 | 3.82 | 2.83 | -15° | 14.00 | 8.30 | |
|
AZAS140MV / FVA140A
AZAS
|
DAIKIN | Floor standing | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.40 | 3.81 | 13.40 | 7.80 | |||
|
AZAS140MY / FVA140A
AZAS
|
DAIKIN | Floor standing | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.40 | 3.81 | 13.40 | 7.80 | |||
|
RPFC-4.0UFE1NH/RAS-4.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.87 | 3.82 | 2.88 | -15° | 9.80 | 7.90 | |
|
RAV-GM1401AT8P-E1/RAV-HM1401FT-E
DI 3ph
|
TOSHIBA | Floor standing | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 4.86 | 3.90 | 3.24 | -15° | 12.10 | 7.60 | |
|
RAV-GM1401ATP-E1/RAV-HM1401FT-E
DI
|
TOSHIBA | Floor standing | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 4.86 | 3.90 | 3.24 | -15° | 12.10 | 7.60 | |
|
RAV-GM1602ATW-E/RAV-HM1601FT-E
DI
|
TOSHIBA | Floor standing | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.20 | 3.90 | 2.83 | -15° | 14.00 | 8.30 | |
|
RAV-GM1101ATP-E/RAV-HM1101FT-E
DI
|
TOSHIBA | Floor standing | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.16 | 3.92 | 3.51 | -15° | 9.50 | 7.60 | |
|
RAV-GM1101AT8P-E/RAV-HM1101FT-E
DI 3ph
|
TOSHIBA | Floor standing | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.16 | 3.92 | 3.51 | -15° | 9.50 | 7.60 | |
|
RZASG140MV1 / FVA140A
RZASG
|
DAIKIN | Floor standing | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.63 | 3.81 | 3.51 | 13.40 | 7.80 | ||
|
RZASG140MY / FVA140A
RZASG
|
DAIKIN | Floor standing | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.63 | 3.81 | 13.40 | 7.80 | |||
|
RZASG140MV / FVA140A
RZASG
|
DAIKIN | Floor standing | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.63 | 3.81 | 13.40 | 7.80 | |||
|
RAV-GM1402AT8W-E/RAV-HM1401FT-E
DI 3ph
|
TOSHIBA | Floor standing | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.35 | 3.90 | 3.34 | -15° | 12.10 | 8.30 | |
|
RZASG100MV1 / FVA100A
RZASG
|
DAIKIN | Floor standing | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.72 | 3.83 | 4.45 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FVA100A
RZASG
|
DAIKIN | Floor standing | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.72 | 3.83 | 4.45 | -10° | 9.50 | 6.00 | |
|
RZASG100MV / FVA100A
RZASG
|
DAIKIN | Floor standing | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.72 | 3.83 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FVA100A
RZASG
|
DAIKIN | Floor standing | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.72 | 3.83 | -10° | 9.50 | 6.00 | ||
|
RZASG140MY1 / FVA140A
RZASG
|
DAIKIN | Floor standing | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.63 | 3.81 | 3.51 | 13.40 | 7.80 | ||
|
RPFC-3.0UFE1NH/RAS-3.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 4.01 | 3.55 | -15° | 6.50 | 6.00 | |
|
RAV-GM1402ATW-E/RAV-HM1401FT-E
DI
|
TOSHIBA | Floor standing | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.53 | 3.90 | 3.29 | -15° | 12.10 | 8.30 | |
|
FDC100VNP-W/FDF100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.43 | 3.94 | 3.69 | -15° | 10.00 | 6.40 | |
|
FDC100VNP-W/FDF100VH1
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.43 | 3.94 | 3.69 | -15° | 10.00 | 6.40 | |
|
RAV-GM1102AT8W-E/RAV-HM1101FT-E
DI 3ph
|
TOSHIBA | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.92 | 3.64 | -15° | 9.50 | 8.30 | |
|
RAV-GM1102ATW-E/RAV-HM1101FT-E
DI
|
TOSHIBA | Floor standing | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.22 | 3.92 | 3.61 | -15° | 9.50 | 8.30 | |
|
PUZ-M100YKA2/PSA-M100KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.00 | 3.45 | -15° | 9.40 | 8.00 | |
|
PUZ-M100VKA2/PSA-M100KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.00 | 3.45 | -15° | 9.40 | 8.00 | |
|
PUZ-M100VKA3/PSA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.00 | 3.45 | -15° | 9.40 | 8.00 | |
|
PUZ-M100YKA3/PSA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.00 | 3.45 | -15° | 9.40 | 8.00 | |
|
RPFC-3.5UFE1NH/RAS-3.5UFESNH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.78 | -15° | 8.60 | 6.50 | |
|
RAV-GM902ATW-E/RAV-HM901FT-E
DI
|
TOSHIBA | Floor standing | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.00 | 3.70 | -15° | 8.00 | 6.30 | |
|
AUW105U4RK7/AUF105UR4RMPA8
Super Inverter R32
|
HISENSE | Floor standing | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.00 | 3.72 | -10° | 10.00 | 7.40 | |
|
FDC71VNX-W/FDF71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.25 | 4.03 | 3.62 | -20° | 7.10 | 6.00 | |
|
FDC71VNX-W/FDF71VH1
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.25 | 4.03 | 3.62 | -20° | 7.10 | 6.00 | |
|
PUZ-ZM100YDA/PSA-M100KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.60 | 4.10 | 3.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PSA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.60 | 4.10 | 3.40 | -20° | 9.50 | 7.80 | |
|
AC140BXPDNH / AC140BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.80 | 4.00 | 3.44 | -20° | 13.40 | 7.80 | |
|
FR212HIDS8*/AIC212HIDS8F*
Floor Standing
|
RIELLO | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.20 | 3.38 | 12.10 | 8.40 | ||
|
FDC90VNP-W/FDF100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.91 | 4.24 | 4.02 | -15° | 9.00 | 6.00 | |
|
FDC90VNP-W/FDF100VH1
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.91 | 4.24 | 4.02 | -15° | 9.00 | 6.00 | |
|
PUZ-ZM100VDA/PSA-M100KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.10 | 3.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PSA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.10 | 3.40 | -20° | 9.50 | 7.80 | |
|
MOX430UL-24HFN8-QRD0W/MFYA400-24HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.45 | -10° | 7.10 | 6.00 | |
|
GUD100ZD1/A-S/GUD100W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | -10° | 10.00 | 7.00 | ||
|
GUD100ZD1/A-S/GUD100W1/NhA-X
MONOSPLITS
|
GREE | Ceiling/Floor | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | -10° | 10.00 | 7.00 |