Filters · 5 active
Manufacturer:
AIRCLASS
CIAT
Vulcano
WESTPOINT
AIRWELL
(19)
ATLANTIC
(17)
AUX
(11)
BOSCH
(61)
BRYANT
(0)
Buderus
(11)
CARRIER
(45)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(2)
DAIKIN
(301)
EQUATION
(2)
FUJI ELECTRIC
(62)
FUJITSU
(136)
Fujitsu Atlantic
(74)
GENERAL
(107)
GREE
(40)
GSS
(0)
HAIER
(116)
HEC
(2)
HEIWA
(3)
HISENSE
(124)
HITACHI
(64)
IVT
(8)
Inventor
(28)
KAYSUN
(12)
LG
(90)
MIDEA
(176)
MITSUBISHI ELECTRIC
(174)
Mitsubishi Heavy Industries
(154)
NORD
(12)
Nobu
(0)
PANASONIC
(173)
RIELLO
(10)
Rotenso
(0)
SAMSUNG
(51)
THERMOR
(16)
TOSHIBA
(102)
Viessmann
(2)
YORK
(8)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
38HM14VS8C-1/42HK07VS8C*
Cassette
|
CIAT | Cassette | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 4.02 | -10° | 4.10 | 3.80 | |
|
UE-EC 26 / UI-ECU M 26
Easy 3 Cool
|
Vulcano | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
38HM14VS8C-1/42HY07VS8C*
Ducted
|
CIAT | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 4.24 | -10° | 4.10 | 4.00 | |
|
38HM14VS8C-1/42HC07JS8C*
Wall mounted
|
CIAT | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 3.90 | 4.11 | -10° | 4.10 | 3.80 | |
|
UE-E3CM 41/2 / UI-E3CU M 26 + UI-E3CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
WIZO-09225.MH / WIZ-09225.MH
WIZ 325
|
WESTPOINT | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 4.00 | -10° | 2.50 | 2.50 | |
|
42HK24VDS8C/38HU24VDS8C
Cassette
|
CIAT | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.05 | -10° | 7.04 | 6.00 | |
|
42HY24VDS8C/38HU24VDS8C
Ducted
|
CIAT | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.14 | -10° | 7.10 | 5.40 | |
|
WIM-09323.MH
WIM 323
|
WESTPOINT | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.35 | -10° | 2.60 | 2.60 | |
|
42HK30VDS8C/38HU30VD8SC
Cassette
|
CIAT | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.00 | -10° | 8.80 | 7.50 | |
|
42HC12VDS8C*/38HU12VDS8C*
Console
|
CIAT | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
42HY30VDS8C/38HU30VDS8C
Ducted
|
CIAT | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.00 | 4.04 | -10° | 8.75 | 8.00 | |
|
WIMO-09325.MH / WIM-09325.MH
WIM 325
|
WESTPOINT | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.30 | -10° | 2.60 | 2.50 | |
|
42HG09JS8C-1/38HG09JS8C-1
Wall mounted
|
CIAT | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.46 | -10° | 2.64 | 2.40 | |
|
WIMO-09323.MH
WIM 323
|
WESTPOINT | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -10° | 2.60 | 2.40 | |
|
AITO-12322.MH/AIT-12322.MH
AIT
|
AIRCLASS | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.01 | -25° | 3.50 | 2.60 | |
|
AITO-09322.MH/AIT-09322.MH
AIT
|
AIRCLASS | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
WITO-09322.MH/WIT-09322.MH
WIT
|
WESTPOINT | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
38HM18VS8C-2/42HY09VS8C*
Ducted
|
CIAT | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 4.29 | -10° | 5.80 | 4.60 | |
|
WIMO-09326.MH / WIM-09326.MH
WIM 326
|
WESTPOINT | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 |