Filters · 4 active
Manufacturer:
BOSCH
CARRIER
TOSHIBA
AIRCLASS
(0)
AIRWELL
(11)
ATLANTIC
(12)
AUX
(4)
BRYANT
(5)
Buderus
(8)
CIAT
(11)
COLIBRI
(3)
CONFORT AIR
(2)
Candy
(5)
DAIKIN
(81)
EQUATION
(1)
FUJI ELECTRIC
(18)
FUJITSU
(56)
Fujitsu Atlantic
(29)
GENERAL
(26)
GREE
(7)
GSS
(0)
HAIER
(234)
HEC
(2)
HEIWA
(1)
HISENSE
(44)
HITACHI
(37)
IVT
(1)
Inventor
(46)
KAYSUN
(19)
LG
(104)
MIDEA
(255)
MITSUBISHI ELECTRIC
(171)
Mitsubishi Heavy Industries
(85)
NORD
(28)
Nobu
(7)
PANASONIC
(33)
RIELLO
(14)
Rotenso
(4)
SAMSUNG
(77)
THERMOR
(12)
Viessmann
(5)
Vulcano
(6)
WESTPOINT
(0)
YORK
(12)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GM561ATP-E1/RAV-HM561FT-E
DI
|
TOSHIBA | Floor standing | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 4.00 | 3.08 | -15° | 5.00 | 2.80 | |
|
RAV-GM2803AT8P-E
BIG DI 3ph
|
TOSHIBA | Ceiling suspended | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.34 | 3.61 | 3.13 | -10° | 23.50 | 12.30 | |
|
CL2000 35 E / CL2000U W 35 E
Climate 2000
|
BOSCH | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
CL2001 35 E / CL2001U W 35 E
Climate 2000
|
BOSCH | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
42QHA012D8S*/38QHA012D8S*
Wall mounted
|
CARRIER | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.38 | -10° | 3.68 | 2.70 | |
|
42QHF012D8S*/38QHF012D8S*
Wall mounted
|
CARRIER | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.38 | -10° | 3.68 | 2.70 | |
|
RAV-GM2803AT8P-E
BIG DI 3ph
|
TOSHIBA | Floor standing | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.12 | 3.53 | 2.48 | -10° | 23.50 | 12.30 | |
|
RAV-GV1401AT8P-E/RAV-HM1401UTP-E
DIC 3ph
|
TOSHIBA | Cassette | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.90 | 3.00 | -15° | 12.10 | 7.80 | |
|
RAV-GM562ATP-E/RAV-HM561FT-E
DI
|
TOSHIBA | Floor standing | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.86 | 4.01 | 3.08 | -15° | 5.00 | 2.80 | |
|
CL5000M 82/4 E / CL3000iU W 26 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 3.80 | 3.40 | -10° | 8.20 | 6.00 | |
|
RAV-GM801ATP-E/RAV-HM801FT-E
DI
|
TOSHIBA | Floor standing | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.89 | 3.81 | 2.41 | -15° | 6.70 | 4.70 | |
|
RAV-GM302ATP-E/RAV-HM301U1TP-E
DI
|
TOSHIBA | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.54 | 3.96 | 3.30 | -15° | 2.50 | 2.60 | |
|
RAV-GV801ATP-E/RAV-HM801KRTP-E
DIC
|
TOSHIBA | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.75 | 3.90 | 3.18 | -15° | 6.70 | 4.80 | |
|
RAV-GV1401ATP-E/RAV-HM1401UTP-E
DIC
|
TOSHIBA | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.90 | 3.13 | -15° | 11.50 | 7.80 | |
|
RAV-GM1602AT8W-E/RAV-HM1601FT-E
DI 3ph
|
TOSHIBA | Floor standing | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.15 | 3.82 | 2.83 | -15° | 14.00 | 8.30 | |
|
RAV-GV1401AT8P-E+RAV-HM1401BTP-E
DIC 3ph
|
TOSHIBA | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.00 | -15° | 12.10 | 7.80 | |
|
RAV-GV1101ATP-E/RAV-HM1101BTP-E
DIC
|
TOSHIBA | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.33 | -15° | 9.50 | 7.60 | |
|
RAV-GV1401ATP-E/RAV-HM1401BTP-E
DIC
|
TOSHIBA | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.05 | -15° | 11.50 | 7.80 | |
|
CL2000 70 E / CL2000U W 70 E
Climate 2000
|
BOSCH | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
CL2001 70 E / CL2001U W 70 E
Climate 2000
|
BOSCH | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
38WHSS042ATA0TEE/40WHSW042DTA0TEE
40WHS
|
CARRIER | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.45 | -15° | 4.20 | 3.30 | |
|
RAS-16B2AVG-E2/RAS-B16B2KVG-E2
SEIYA
|
TOSHIBA | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.45 | -15° | 4.20 | 3.30 | |
|
RAS-16B2AVG-E2/RAS-B16B2KV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.45 | -15° | 4.20 | 3.30 | |
|
RAS-16LAV2G-E/RAS-B16LKV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.45 | -15° | 4.20 | 3.30 | |
|
42QCE021D8S* / 38QCE021D8S*
Wall mounted
|
CARRIER | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.26 | -10° | 6.12 | 4.75 | |
|
RAV-GV1101AT8P-E/RAV-HM1101BTP-E
DIC 3ph
|
TOSHIBA | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.30 | 3.80 | 3.40 | -15° | 9.50 | 7.60 | |
|
42QHA024D8S*/38QHA024D8S*
Wall mounted
|
CARRIER | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
42QHF024D8S*/38QHF024D8S*
Wall mounted
|
CARRIER | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
RAV-GM1401AT8P-E1/RAV-HM1401FT-E
DI 3ph
|
TOSHIBA | Floor standing | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 4.86 | 3.90 | 3.24 | -15° | 12.10 | 7.60 | |
|
RAV-GM1401ATP-E1/RAV-HM1401FT-E
DI
|
TOSHIBA | Floor standing | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 4.86 | 3.90 | 3.24 | -15° | 12.10 | 7.60 | |
|
RAV-GM2803AT8P-E
BIG DI 3ph
|
TOSHIBA | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.32 | 3.70 | 3.18 | -10° | 23.50 | 12.30 | |
|
RAV-GM561ATP-E1/RAV-HM561KRTP-E
DI
|
TOSHIBA | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.31 | 4.00 | 3.42 | -15° | 5.00 | 2.80 | |
|
38WHSS050ATA0TEE/40WHSW050DTA0TEE
40WHS
|
CARRIER | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.23 | -15° | 5.00 | 3.70 | |
|
RAS-18B2AVG-E2/RAS-B18B2KVG-E2
SEIYA
|
TOSHIBA | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.23 | -15° | 5.00 | 3.70 | |
|
RAS-18B2AVG-E2/RAS-B18B2KV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.23 | -15° | 5.00 | 3.70 | |
|
RAS-18LAV2G-E/RAS-B18LKV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.23 | -15° | 5.00 | 3.70 | |
|
RAV-GM402ATP-E/RAV-HM401U1TP-E
DI
|
TOSHIBA | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.03 | -15° | 3.60 | 2.70 | |
|
RAV-GV561ATP-E/RAV-HM561BTP-E
DIC
|
TOSHIBA | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.20 | 3.90 | 3.21 | -15° | 5.00 | 2.80 | |
|
RAV-GM1602ATW-E/RAV-HM1601FT-E
DI
|
TOSHIBA | Floor standing | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.20 | 3.90 | 2.83 | -15° | 14.00 | 8.30 | |
|
RAV-GM2803AT8P-E/RAV-RM2801DTP-E2
DI 3ph
|
TOSHIBA | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.70 | 3.15 | -10° | 22.50 | 12.30 | |
|
42QHG012D8SJ-2/38QHG012D8SJ-1
Wall mounted
|
CARRIER | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.50 | -10° | 3.50 | 2.80 | |
|
42QHG012D8SJ-B/38QHG012D8SJ-1
Wall mounted
|
CARRIER | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.50 | -10° | 3.50 | 2.80 | |
|
CL5001L 26 E / CL5001iU 4CC 26 E
Climate 5001 L
|
BOSCH | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.09 | -10° | 2.60 | 2.00 | |
|
42QTD009D8SN*/38QUS009D8SX*
Cassette
|
CARRIER | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.09 | -10° | 2.60 | 2.00 | |
|
38WHSS071ATA0TEE/40WHSW071DTA0TEE
40WHS
|
CARRIER | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 6.50 | 4.40 | |
|
RAS-24B2AVG-E2/RAS-B24B2KVG-E2
SEIYA
|
TOSHIBA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 6.50 | 4.40 | |
|
RAS-24B2AVG-E2/RAS-B24B2KV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 6.50 | 4.40 | |
|
RAS-24LAV2G-E/RAS-B24LKV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 6.50 | 4.40 | |
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.14 | 3.83 | 3.03 | -10° | 20.00 | 11.40 | |
|
CL5000M 105/4 / CL3000iU W 53 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.10 | -10° | 10.50 | 8.10 |