Filters · 3 active
Manufacturer:
BOSCH
CARRIER
AIRCLASS
(2)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BRYANT
(0)
Buderus
(4)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(4)
Candy
(0)
DAIKIN
(270)
EQUATION
(0)
FUJI ELECTRIC
(138)
FUJITSU
(332)
Fujitsu Atlantic
(165)
GENERAL
(210)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(140)
IVT
(0)
Inventor
(14)
KAYSUN
(0)
LG
(14)
MIDEA
(33)
MITSUBISHI ELECTRIC
(456)
Mitsubishi Heavy Industries
(143)
NORD
(0)
Nobu
(0)
PANASONIC
(313)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(98)
THERMOR
(0)
TOSHIBA
(301)
Viessmann
(0)
Vulcano
(2)
WESTPOINT
(5)
YORK
(8)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
38WHSS020ATA0TEE/40WHSW020DTA0TEE
40WHS
|
CARRIER | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.91 | -15° | 2.00 | 2.00 | |
|
38WHSS025ATA0TEE/40WHSW025DTA0TEE
40WHS
|
CARRIER | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.81 | -15° | 2.50 | 2.10 | |
|
38WHSS042ATA0TEE/40WHSW042DTA0TEE
40WHS
|
CARRIER | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.45 | -15° | 4.20 | 3.30 | |
|
38WHSS050ATA0TEE/40WHSW050DTA0TEE
40WHS
|
CARRIER | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.23 | -15° | 5.00 | 3.70 | |
|
38WHSS071ATA0TEE/40WHSW071DTA0TEE
40WHS
|
CARRIER | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 6.50 | 4.40 | |
|
38WHSS035ATA0TEE/40WHSW035DTA0TEE
40WHS
|
CARRIER | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.00 | -15° | 3.30 | 2.30 | |
|
CL3000i 70 E / CL3000iU W 70 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
CL3000i 70 E / CL3200iU W 70 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
CL3000i 53 E / CL3000iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
CL3000i 53 E / CL3200iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
38WH5M100C1A0TEE/40WHHW035D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 4.07 | -20° | 6.00 | 4.19 | |
|
38WHSM020A1A0TEE/40WHMW020D1A0TEE
40WHM
|
CARRIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.60 | 3.91 | -15° | 2.00 | 2.00 | |
|
38WHSH071A1A0TEE/40WHHW071D1A0TEE
40WHH
|
CARRIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.40 | -15° | 7.00 | 6.30 | |
|
38WHSH071A1A0TEE/40WHHB071D1A0TEE
40WHH
|
CARRIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.40 | -15° | 7.00 | 6.30 | |
|
38WH5M100C1A0TEE/40WHHW046D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 4.14 | -20° | 7.10 | 4.93 | |
|
38WHSM035A1A0TEE/40WHMW035D1A0TEE
40WHM
|
CARRIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 4.14 | -15° | 3.30 | 2.70 | |
|
38WH5M100C1A0TEE/40WHHW046D1A0TEE/40WHHW035D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 4.20 | -20° | 8.10 | 5.49 | |
|
38WHSM025A1A0TEE/40WHMW025D1A0TEE
40WHM
|
CARRIER | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 2.50 | 2.40 | |
|
38WHSM050A1A0TEE/40WHMW050D1A0TEE
40WHM
|
CARRIER | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.60 | -15° | 5.00 | 3.80 | |
|
38WHSM071A1A0TEE/40WHMW071D1A0TEE
40WHM
|
CARRIER | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.33 | -15° | 6.50 | 5.40 | |
|
CL6100i 50 E / CL6100i-W 50 E
Climate 6100i
|
BOSCH | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.60 | 4.31 | -20° | 2.50 | 2.80 | |
|
38WH4M080C1A0TEE/40WHHW035D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.19 | 4.30 | 4.63 | -20° | 6.00 | 4.27 | |
|
38WHSM042A1A0TEE/40WHMW042D1A0TEE
40WHM
|
CARRIER | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.73 | -15° | 4.20 | 3.60 | |
|
CLC6101i 50 HE / CLC6101i-W 50 HE
Climate Class 6100i
|
BOSCH | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 4.27 | -20° | 2.50 | 2.80 | |
|
38WH3M052C1A0TEE/40WHHW035D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.60 | 3.72 | -20° | 5.20 | 3.50 | |
|
CL6100i 65 E / CL6100i-W 65 E
Climate 6100i
|
BOSCH | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.28 | -20° | 3.50 | 3.20 | |
|
38WH3M052C1A0TEE/40WHHW046D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 3.74 | -20° | 5.20 | 3.50 | |
|
CLC6101i 65 HE / CLC6101i-W 65 HE
Climate Class 6100i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.60 | 4.20 | -20° | 3.50 | 3.20 | |
|
38WH3M052C1A0TEE/40WHHW035D1A0TEE/40WHHW035D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 3.78 | -20° | 5.20 | 3.50 | |
|
38WH3M052C1A0TEE/40WHHW046D1A0TEE/40WHHW035D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 3.74 | -20° | 5.20 | 3.50 | |
|
38WH5M100C1A0TEE/40WHHW046D1A0TEE/40WHHW046D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.25 | -20° | 9.20 | 6.23 | |
|
38WHSH050A1A0TEE/40WHHW050D1A0TEE
40WHH
|
CARRIER | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.77 | -15° | 5.00 | 4.30 | |
|
38WHSH050A1A0TEE/40WHHB050D1A0TEE
40WHH
|
CARRIER | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.77 | -15° | 5.00 | 4.30 | |
|
38WHSH046A1A0TEE/40WHPF046D1A0TEE
40WHP
|
CARRIER | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 3.62 | -15° | 4.60 | 4.00 | |
|
38WHSH046A1A0TEE/40WHHW046D1A0TEE
40WHH
|
CARRIER | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 3.62 | -15° | 4.60 | 4.00 | |
|
38WHSH046A1A0TEE/40WHHB046D1A0TEE
40WHH
|
CARRIER | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 3.62 | -15° | 4.60 | 4.00 | |
|
38WHSH035A1A0TEE/40WHHW035D1A0TEE
40WHH
|
CARRIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.69 | 4.93 | 3.89 | -15° | 3.50 | 3.20 | |
|
38WHSH035A1A0TEE/40WHHB035D1A0TEE
40WHH
|
CARRIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.69 | 4.93 | 3.89 | -15° | 3.50 | 3.20 | |
|
38WH4M080C1A0TEE/40WHHW046D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.55 | 4.40 | 4.70 | -20° | 7.10 | 5.02 | |
|
38WHSH060A1A0TEE/40WHHW060D1A0TEE
40WHH
|
CARRIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.72 | -15° | 6.10 | 4.70 | |
|
38WHSH060A1A0TEE/40WHHB060D1A0TEE
40WHH
|
CARRIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.72 | -15° | 6.10 | 4.70 | |
|
38WHSH035A1A0TEE/40WHPF035D1A0TEE
40WHP
|
CARRIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.78 | 4.93 | 3.89 | -15° | 3.50 | 3.20 | |
|
38WH2M040C1A0TEE/40WHHW035D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.20 | 4.70 | 4.68 | -20° | 4.00 | 3.10 | |
|
38WH4M080C1A0TEE/40WHHW046D1A0TEE/40WHHW035D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.74 | 4.50 | 4.74 | -20° | 8.00 | 5.20 | |
|
38WH4M080C1A0TEE/40WHHW046D1A0TEE/40WHHW046D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.74 | 4.50 | 4.74 | -20° | 8.00 | 5.20 | |
|
38WHSH025A1A0TEE/40WHPF025D1A0TEE
40WHP
|
CARRIER | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.32 | -15° | 2.50 | 2.50 | |
|
CLC8001i 25 E / CLC8001i-W 25 E
Climate Class 8000i
|
BOSCH | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.25 | -15° | 2.50 | 2.80 | |
|
CLC8001i 25 E / CLC8001i-W 25 ET
Climate Class 8000i
|
BOSCH | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.25 | -15° | 2.50 | 2.80 | |
|
CLC8001i 25 E / CLC8001i-W 25 ES
Climate Class 8000i
|
BOSCH | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.25 | -15° | 2.50 | 2.80 | |
|
CLC8001i 25 E / CLC8001i-W 25 ER
Climate Class 8000i
|
BOSCH | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.25 | -15° | 2.50 | 2.80 |