Filters · 3 active
Manufacturer:
BOSCH
CARRIER
AIRCLASS
(2)
AIRWELL
(16)
ATLANTIC
(15)
AUX
(4)
BRYANT
(0)
Buderus
(18)
CIAT
(2)
COLIBRI
(2)
CONFORT AIR
(2)
Candy
(2)
DAIKIN
(196)
EQUATION
(0)
FUJI ELECTRIC
(19)
FUJITSU
(60)
Fujitsu Atlantic
(28)
GENERAL
(64)
GREE
(27)
GSS
(0)
HAIER
(128)
HEC
(0)
HEIWA
(3)
HISENSE
(130)
HITACHI
(47)
IVT
(9)
Inventor
(35)
KAYSUN
(4)
LG
(35)
MIDEA
(198)
MITSUBISHI ELECTRIC
(100)
Mitsubishi Heavy Industries
(68)
NORD
(16)
Nobu
(0)
PANASONIC
(116)
RIELLO
(2)
Rotenso
(0)
SAMSUNG
(59)
THERMOR
(15)
TOSHIBA
(113)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(13)
YORK
(2)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
38WHSM020A1A0TEE/40WHMW020D1A0TEE
40WHM
|
CARRIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.60 | 3.91 | -15° | 2.00 | 2.00 | |
|
38WHSM035A1A0TEE/40WHMW035D1A0TEE
40WHM
|
CARRIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 4.14 | -15° | 3.30 | 2.70 | |
|
38WHSM025A1A0TEE/40WHMW025D1A0TEE
40WHM
|
CARRIER | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 2.50 | 2.40 | |
|
CL4000i 26 E / CL4000iU W 26 E
Climate 4000i
|
BOSCH | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 4.21 | -10° | 2.90 | 2.40 | |
|
CL4000i 35 E / CL4000iU W 35 E
Climate 4000i
|
BOSCH | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.81 | -10° | 3.50 | 2.40 | |
|
CL6100i 50 E / CL6100i-W 50 E
Climate 6100i
|
BOSCH | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.60 | 4.31 | -20° | 2.50 | 2.80 | |
|
CL6000iP 35 / CL6000iP W 35
Climate 6000iP
|
BOSCH | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
CL6000iP 35 / CL6000iP W 35 F
Climate 6000iP
|
BOSCH | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
CL4000i 52 E / CL4000iU W 52 E
Climate 4000i
|
BOSCH | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -10° | 5.20 | 3.40 | |
|
CL5100i 25 HE/CL5100i W 25 HE
Climate 5100i
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.20 | -10° | 2.80 | 2.60 | |
|
CL5100i 35 HE/CL5100i W 35 HE
Climate 5100i
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 3.50 | 2.60 | |
|
42QHG012D8SH*/38QHG012D8SH*
Wall mounted
|
CARRIER | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 3.50 | 2.60 | |
|
42QCE009D8SH*/38QCE009D8SH*
Wall mounted
|
CARRIER | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.30 | -10° | 3.50 | 2.60 | |
|
42QCE012D8SH*/38QCE012D8SH*
Wall mounted
|
CARRIER | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.30 | -10° | 3.52 | 2.60 | |
|
42QCE012D8SH/38QCE012D8SH
Wall mounted
|
CARRIER | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 3.50 | 2.60 | |
|
38WHSM042A1A0TEE/40WHMW042D1A0TEE
40WHM
|
CARRIER | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.73 | -15° | 4.20 | 3.60 | |
|
CL6001i 35 E / CL6001iU W 35 E
Climate 6000i
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.40 | |
|
CL6102i 35 HE / CL6102i W 35 HE
Climate 6102i
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.40 | |
|
42QHE12D8SH*/38QHE12D8SH*
Wall mounted
|
CARRIER | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.01 | -10° | 3.50 | 2.40 | |
|
CLC6101i 50 HE / CLC6101i-W 50 HE
Climate Class 6100i
|
BOSCH | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 4.27 | -20° | 2.50 | 2.80 | |
|
38WH3M052C1A0TEE/40WHHW035D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.60 | 3.72 | -20° | 5.20 | 3.50 | |
|
CL6100i 65 E / CL6100i-W 65 E
Climate 6100i
|
BOSCH | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.28 | -20° | 3.50 | 3.20 | |
|
CL6001i 26 E / CL6001iU W 26 E
Climate 6000i
|
BOSCH | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.54 | -10° | 2.60 | 2.40 | |
|
CL6102i 25 HE / CL6102i W 25 HE
Climate 6102i
|
BOSCH | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.54 | -10° | 2.60 | 2.40 | |
|
38WH3M052C1A0TEE/40WHHW046D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 3.74 | -20° | 5.20 | 3.50 | |
|
CLC6101i 65 HE / CLC6101i-W 65 HE
Climate Class 6100i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.60 | 4.20 | -20° | 3.50 | 3.20 | |
|
CL7000i 41 E / CL7000iU W 41 E
Climate 7000i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 | |
|
CL7000i 41 E / CL7000iU W 41 ES
Climate 7000i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 | |
|
CL7000i 41 E / CL7000iU W 41 EB
Climate 7000i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 | |
|
38WH3M052C1A0TEE/40WHHW035D1A0TEE/40WHHW035D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 3.78 | -20° | 5.20 | 3.50 | |
|
38WH3M052C1A0TEE/40WHHW046D1A0TEE/40WHHW035D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 3.74 | -20° | 5.20 | 3.50 | |
|
CL7000M 53/2 E /CL5000iU W 26 E +CL5000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.20 | -10° | 5.30 | 4.50 | |
|
CL7000M 53/2 E /CL4000iU W 26 E +CL4000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.20 | -10° | 5.30 | 4.50 | |
|
CL6000iP 26 / CL6000iP W 26 F
Climate 6000iP
|
BOSCH | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
CL6000iP 26 / CL6000iP W 26
Climate 6000iP
|
BOSCH | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
42QCE009D8SH/38QCE009D8SH
Wall mounted
|
CARRIER | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.30 | -10° | 2.60 | 2.50 | |
|
42QHG009D8SH*/38QHG009D8SH*
Wall mounted
|
CARRIER | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.46 | -10° | 2.64 | 2.40 | |
|
42QHE09D8SH*/38QHE09D8SH*
Wall mounted
|
CARRIER | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.00 | 4.60 | 4.51 | -10° | 2.64 | 2.40 | |
|
CL7000M 53/2 E /CL6001iU W 26 E +CL6001iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 4.50 | -10° | 5.30 | 4.40 | |
|
42QCE018D8SH/38QCE018D8SH
Wall mounted
|
CARRIER | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
38WHSH050A1A0TEE/40WHHW050D1A0TEE
40WHH
|
CARRIER | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.77 | -15° | 5.00 | 4.30 | |
|
38WHSH050A1A0TEE/40WHHB050D1A0TEE
40WHH
|
CARRIER | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.77 | -15° | 5.00 | 4.30 | |
|
38WHSH046A1A0TEE/40WHPF046D1A0TEE
40WHP
|
CARRIER | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 3.62 | -15° | 4.60 | 4.00 | |
|
38WHSH046A1A0TEE/40WHHW046D1A0TEE
40WHH
|
CARRIER | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 3.62 | -15° | 4.60 | 4.00 | |
|
38WHSH046A1A0TEE/40WHHB046D1A0TEE
40WHH
|
CARRIER | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 3.62 | -15° | 4.60 | 4.00 | |
|
CL7100i 50 HE / CL7100i W 50 HE
Climate 7100i
|
BOSCH | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
CL7100i 50 HE / CL7100i W 50 HES
Climate 7100i
|
BOSCH | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
CL7100i 50 HE / CL7100i W 50 HEB
Climate 7100i
|
BOSCH | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
42QHP018E8SH*/38QHP018E8SH*
Wall mounted
|
CARRIER | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.01 | -10° | 5.00 | 4.20 | |
|
42QCE024D8SH/38QCE024D8SH
Wall mounted
|
CARRIER | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 |