Filters · 4 active
Manufacturer:
BOSCH
GREE
Vulcano
AIRCLASS
(2)
AIRWELL
(19)
ATLANTIC
(17)
AUX
(11)
BRYANT
(0)
Buderus
(11)
CARRIER
(45)
CIAT
(10)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(2)
DAIKIN
(301)
EQUATION
(2)
FUJI ELECTRIC
(62)
FUJITSU
(136)
Fujitsu Atlantic
(74)
GENERAL
(107)
GSS
(0)
HAIER
(116)
HEC
(2)
HEIWA
(3)
HISENSE
(124)
HITACHI
(64)
IVT
(8)
Inventor
(28)
KAYSUN
(12)
LG
(90)
MIDEA
(176)
MITSUBISHI ELECTRIC
(174)
Mitsubishi Heavy Industries
(154)
NORD
(12)
Nobu
(0)
PANASONIC
(173)
RIELLO
(10)
Rotenso
(0)
SAMSUNG
(51)
THERMOR
(16)
TOSHIBA
(102)
Viessmann
(2)
WESTPOINT
(6)
YORK
(8)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CL2000 26 E / CL2000U W 26 E
Climate 2000
|
BOSCH | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
CL2001 26 E / CL2001U W 26 E
Climate 2000
|
BOSCH | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
UE-EC 26 / UI-ECU M 26
Easy 3 Cool
|
Vulcano | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
GWH07QAXA-K6DNC2Z
MONOSPLITS
|
GREE | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 4.06 | -10° | 2.20 | 2.10 | |
|
GWH07ALAXA-K6DNA4Z
MONOSPLITS
|
GREE | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 4.06 | -10° | 2.20 | 2.10 | |
|
GWH07ALAXA-K6DNA1Z
MONOSPLITS
|
GREE | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 4.06 | -10° | 2.20 | 2.10 | |
|
GWH07AGA-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 4.06 | -10° | 2.20 | 2.10 | |
|
CL5000M 41/2 E / CL6001iU W 26 E + CL6001iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 4.18 | -10° | 4.10 | 3.80 | |
|
CL5000L 70 E / CL5000iU 4C 70 E
Climate 5000i L
|
BOSCH | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.00 | 6.00 | |
|
CL5000M 41/2 E / CL5000iU W 26 E + CL5000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
UE-E3CM 41/2 / UI-E3CU M 26 + UI-E3CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
CL5000L 70 E / CL5000iL CF 70 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
GWH09AGAXB-K6DNA1C
MONOSPLITS
|
GREE | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 4.00 | -10° | 2.50 | 2.50 | |
|
CL5000L 35 E / CL5000iU CN 35 E
Climate 5000i L
|
BOSCH | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
GWH09AGBXB-K6DNA1E
MONOSPLITS
|
GREE | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.20 | 4.08 | -10° | 2.70 | 2.60 | |
|
GWH09ALBXB-K6DNA2D
MONOSPLITS
|
GREE | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.20 | 4.08 | -10° | 2.70 | 2.60 | |
|
CL5001L 70 E / CL5000iU 4C 70 E
Climate 5001 L
|
BOSCH | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.01 | -10° | 7.10 | 6.20 | |
|
GWH09ACCXB-K6DNA1Y
MONOSPLITS
|
GREE | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 4.28 | -10° | 2.70 | 2.70 | |
|
CL5000L 70 E / CL5000iU D 70 E
Climate 5000i U
|
BOSCH | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
GWHD(18)NK6OO GWH09YCXB-K6DNA2C/I*2
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.20 | 4.52 | -10° | 5.30 | 4.10 | |
|
GWHD(14)NK6OO GWH(07)YCXB-K6DNA2C/I*2
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.20 | 4.54 | -10° | 4.10 | 3.80 | |
|
CL5000i 26 E / CL5000iU W 26 E
Climate 5000i
|
BOSCH | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.35 | -10° | 2.60 | 2.60 | |
|
GWH18AKCXF-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 4.00 | -10° | 5.30 | 4.20 | |
|
CL5000L 88 E / CL5000iL 4C 88 E
Climate 5000i L
|
BOSCH | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
GWH12ATCXB-K5DNA1B
MONOSPLITS
|
GREE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 4.20 | -10° | 3.20 | 2.80 | |
|
GWH18ACDXF-K6DNA1C
MONOSPLITS
|
GREE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.20 | 4.00 | -10° | 5.30 | 4.30 | |
|
GWH12YCXD-K6DNA2B
MONOSPLITS
|
GREE | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.40 | 4.00 | -10° | 3.50 | 3.20 | |
|
GWH12YCXD-K6DNA1Z
MONOSPLITS
|
GREE | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.40 | 4.00 | -10° | 3.50 | 3.20 | |
|
CL4000i 26 E / CL4000iU W 26 E
Climate 4000i
|
BOSCH | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 4.21 | -10° | 2.90 | 2.40 | |
|
GWH18YDXF-K6DNA2Y
MONOSPLITS
|
GREE | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.30 | 4.20 | -10° | 5.30 | 4.30 | |
|
CL6100i 50 E / CL6100i-W 50 E
Climate 6100i
|
BOSCH | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.60 | 4.31 | -20° | 2.50 | 2.80 | |
|
CL5000L 88 E / CL5000iL D 88 E
Climate 5000i L
|
BOSCH | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
GWH09AUCXB-K6DNA2A
MONOSPLITS
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.41 | -10° | 2.70 | 2.70 | |
|
GWH09AUCXB-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.41 | -10° | 2.70 | 2.70 | |
|
GWH09AWCXB-K6DNA4G
MONOSPLITS
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.45 | -10° | 2.70 | 2.70 | |
|
GWH09ATCXB-K6DNA4G
MONOSPLITS
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.45 | -10° | 2.70 | 2.70 | |
|
GWH09ATCXB-K6DNA3G
MONOSPLITS
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.45 | -10° | 2.70 | 2.70 | |
|
GWH09AGCXB-K6DNA1H
MONOSPLITS
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.45 | -10° | 2.70 | 2.70 | |
|
GWH09AGCXB-K6DNA2H
MONOSPLITS
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.45 | -10° | 2.70 | 2.70 | |
|
CL5100i 25 HE/CL5100i W 25 HE
Climate 5100i
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.20 | -10° | 2.80 | 2.60 | |
|
CL6001i 35 E / CL6001iU W 35 E
Climate 6000i
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.40 | |
|
CL6102i 35 HE / CL6102i W 35 HE
Climate 6102i
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.40 | |
|
GWH12AVCXD-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 3.00 | |
|
CLC6101i 50 HE / CLC6101i-W 50 HE
Climate Class 6100i
|
BOSCH | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 4.27 | -20° | 2.50 | 2.80 | |
|
GWH12AUCXD-K6DNA1C
MONOSPLITS
|
GREE | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.51 | 3.20 | |
|
CL6100i 65 E / CL6100i-W 65 E
Climate 6100i
|
BOSCH | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.28 | -20° | 3.50 | 3.20 | |
|
CL6001i 26 E / CL6001iU W 26 E
Climate 6000i
|
BOSCH | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.54 | -10° | 2.60 | 2.40 | |
|
CL6102i 25 HE / CL6102i W 25 HE
Climate 6102i
|
BOSCH | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.54 | -10° | 2.60 | 2.40 | |
|
CLC6101i 65 HE / CLC6101i-W 65 HE
Climate Class 6100i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.60 | 4.20 | -20° | 3.50 | 3.20 | |
|
CL7000i 41 E / CL7000iU W 41 E
Climate 7000i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 |