Filters · 3 active
Manufacturer:
CIAT
HEC
AIRCLASS
(4)
AIRWELL
(77)
ATLANTIC
(31)
AUX
(66)
BOSCH
(113)
BRYANT
(1)
Buderus
(30)
CARRIER
(118)
COLIBRI
(3)
CONFORT AIR
(2)
Candy
(13)
DAIKIN
(502)
EQUATION
(4)
FUJI ELECTRIC
(161)
FUJITSU
(378)
Fujitsu Atlantic
(190)
GENERAL
(236)
GREE
(96)
GSS
(4)
HAIER
(378)
HEIWA
(7)
HISENSE
(301)
HITACHI
(137)
IVT
(9)
Inventor
(109)
KAYSUN
(57)
LG
(255)
MIDEA
(641)
MITSUBISHI ELECTRIC
(490)
Mitsubishi Heavy Industries
(336)
NORD
(32)
Nobu
(1)
PANASONIC
(284)
RIELLO
(33)
Rotenso
(5)
SAMSUNG
(139)
THERMOR
(46)
TOSHIBA
(224)
Viessmann
(19)
Vulcano
(11)
WESTPOINT
(22)
YORK
(31)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
38HM14VS8C-1/42HK07VS8C*
Cassette
|
CIAT | Cassette | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 4.02 | -10° | 4.10 | 3.80 | |
|
42HF09JS8C/38HF09JS8C
Wall mounted
|
CIAT | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.82 | -10° | 2.80 | 2.60 | |
|
2HEC35RECO-OUM/HEC25RECO-IN/HEC25RECO-IN
Super Match Multi
|
HEC | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 4.00 | -10° | 3.60 | 2.90 | |
|
2HEC35RECO-OUM/HEC25RECO-IN/HEC35RECO-IN
Super Match Multi
|
HEC | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 4.00 | -10° | 3.60 | 2.90 | |
|
HEC50RECO-IN/HEC50RECO-OU
Wall mounted - R+
|
HEC | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.60 | -10° | 4.80 | 3.60 | |
|
38HM14VS8C-1/42HY07VS8C*
Ducted
|
CIAT | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 4.24 | -10° | 4.10 | 4.00 | |
|
38HM14VS8C-1/42HC07JS8C*
Wall mounted
|
CIAT | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 3.90 | 4.11 | -10° | 4.10 | 3.80 | |
|
38HM18VS8C-2/42HK09VS8C*
Cassette
|
CIAT | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.79 | -10° | 5.40 | 4.50 | |
|
42HK24VDS8C/38HU24VDS8C
Cassette
|
CIAT | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.05 | -10° | 7.04 | 6.00 | |
|
42HK42VDS8C*/38HU42VDS8C*
Cassette
|
CIAT | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.59 | 12.10 | 9.50 | ||
|
42HC09JS8C*/38HC09JS8C*
Wall mounted
|
CIAT | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.85 | -10° | 2.75 | 2.50 | |
|
42HC12JS8C*/38HC12JS8C*
Wall mounted
|
CIAT | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.65 | 2.50 | |
|
38HM18VS8C-2/42HC09JS8C*
Wall mounted
|
CIAT | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 3.67 | -10° | 5.35 | 4.40 | |
|
42HU18VDS8C/38HU18VDS8C
Ceiling suspended
|
CIAT | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -10° | 5.30 | 4.00 | |
|
42HK36VDS8C/38HU36VDT8C
Cassette
|
CIAT | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.61 | -10° | 10.50 | 8.00 | |
|
42HU24VDS8C/38HU24VDS8C
Ceiling suspended
|
CIAT | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.90 | -10° | 7.20 | 5.50 | |
|
42HY24VDS8C/38HU24VDS8C
Ducted
|
CIAT | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.14 | -10° | 7.10 | 5.40 | |
|
42HU36VDS8C/38HU36VDT8C
Ceiling suspended
|
CIAT | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.61 | -10° | 10.80 | 8.70 | |
|
42HK36VDS8C/38HU36VDS8C
Cassette
|
CIAT | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 3.55 | -10° | 10.50 | 8.20 | |
|
42HY36VDS8C/38HU36VDT8C
Ducted
|
CIAT | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.67 | -10° | 10.60 | 8.80 | |
|
42HY12VDS8C/38HU12VDS8C
Ducted
|
CIAT | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.78 | -10° | 3.50 | 2.70 | |
|
42HK12VDS8C/38HU12VDS8C
Cassette
|
CIAT | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.65 | -10° | 3.50 | 2.75 | |
|
42HY42VDS8C*/38HU42VD8C*
Ducted
|
CIAT | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.91 | 12.10 | 9.30 | ||
|
42HY60VDS8C/38HU60VDT8C
Ducted
|
CIAT | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.52 | 15.40 | 12.70 | ||
|
42HY36VDS8C/38HU36VDS8C
Ducted
|
CIAT | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.69 | -10° | 10.50 | 8.40 | |
|
42HK30VDS8C/38HU30VD8SC
Cassette
|
CIAT | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.00 | -10° | 8.80 | 7.50 | |
|
42HY18VDS8C/38HU18VDS8C
Ducted
|
CIAT | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.00 | 3.82 | -10° | 5.40 | 4.30 | |
|
42HG12JS8C-1/38HG12JS8C-1
Wall mounted
|
CIAT | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 3.50 | 2.60 | |
|
42HC18VDS8C*/38HU18VDS8C*
Console
|
CIAT | Console | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.59 | -10° | 4.90 | 4.20 | |
|
42HC12VDS8C*/38HU12VDS8C*
Console
|
CIAT | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
42HY30VDS8C/38HU30VDS8C
Ducted
|
CIAT | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.00 | 4.04 | -10° | 8.75 | 8.00 | |
|
42HE24JS8C*/38HE24JS8C*
Wall mounted
|
CIAT | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.20 | 3.74 | -10° | 6.85 | 5.00 | |
|
42HU36VDS8C/38HU36VDS8C
Ceiling suspended
|
CIAT | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.62 | -10° | 10.50 | 8.60 | |
|
42HE18JS8C*/38HE18JS8C*
Wall mounted
|
CIAT | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.40 | 3.77 | -10° | 5.20 | 4.30 | |
|
42HG09JS8C-1/38HG09JS8C-1
Wall mounted
|
CIAT | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.46 | -10° | 2.64 | 2.40 | |
|
38HM18VS8C-2/42HY09VS8C*
Ducted
|
CIAT | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 4.29 | -10° | 5.80 | 4.60 |