Filters · 4 active
Manufacturer:
DAIKIN
EQUATION
SAMSUNG
AIRCLASS
(2)
AIRWELL
(70)
ATLANTIC
(38)
AUX
(59)
BOSCH
(73)
BRYANT
(6)
Buderus
(28)
CARRIER
(106)
CIAT
(35)
COLIBRI
(5)
CONFORT AIR
(3)
Candy
(16)
FUJI ELECTRIC
(113)
FUJITSU
(293)
Fujitsu Atlantic
(143)
GENERAL
(155)
GREE
(71)
GSS
(4)
HAIER
(520)
HEC
(5)
HEIWA
(6)
HISENSE
(270)
HITACHI
(118)
IVT
(3)
Inventor
(135)
KAYSUN
(62)
LG
(265)
MIDEA
(718)
MITSUBISHI ELECTRIC
(463)
Mitsubishi Heavy Industries
(266)
NORD
(51)
Nobu
(8)
PANASONIC
(155)
RIELLO
(38)
Rotenso
(8)
THERMOR
(56)
TOSHIBA
(216)
Viessmann
(22)
Vulcano
(16)
WESTPOINT
(17)
YORK
(35)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AZAS125MV / FVA125A
AZAS
|
DAIKIN | Floor standing | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.30 | 3.56 | 3.75 | 12.10 | 6.00 | ||
|
AR12TXHQASIN/AR12TXHQASIX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.78 | 2.70 | |
|
AR12TXHQBWKN/AR12TXHQBWKX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.78 | 2.70 | |
|
AR40H12C1AMN/AR40H12C1AMX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.60 | 2.70 | |
|
AR40H12C1BMN/AR40H12C1BMX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.60 | 2.70 | |
|
AR40F12C0AMN/AR40F12C0AMX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.60 | 2.70 | |
|
AR40F12C0BMN/AR40F12C0BMX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.60 | 2.70 | |
|
AJ080TXJ4KH / AJ020TNAPKH / AJ068TNAPKH
FJM
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.80 | 3.61 | -10° | 7.45 | 5.20 | |
|
AJ080TXJ4KG / AR60F07C1AW / AR70F24C1AW
FJM
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.28 | 3.80 | 3.61 | -10° | 7.45 | 5.20 | |
|
RXM50A9 / FFA50A9
RXM
|
DAIKIN | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.98 | 3.90 | 3.49 | -10° | 5.00 | 3.84 | |
|
AZAS100MV1 / FCAG100B
AZAS
|
DAIKIN | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.67 | 3.85 | 3.71 | -10° | 9.50 | 6.00 | |
|
AZAS100MY1 / FCAG100B
AZAS
|
DAIKIN | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.67 | 3.85 | 3.71 | -10° | 9.50 | 6.00 | |
|
AJ068TXJ3KG / AR60F07C1AW / AR70F18C1AW
FJM
|
SAMSUNG | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.95 | 3.85 | 3.92 | -10° | 6.50 | 5.09 | |
|
RXF71D9 / FTXF71D
RXF
|
DAIKIN | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.15 | 3.81 | 3.15 | -10° | 7.10 | 6.20 | |
|
RXF71D9 / FTXF71F
RXF
|
DAIKIN | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.15 | 3.81 | 3.15 | -10° | 7.10 | 6.20 | |
|
RZASG100MV1 / FFA50A9 / FFA50A9
RZASG
|
DAIKIN | Cassette | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.49 | 3.90 | 3.90 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FFA50A9 / FFA50A9
RZASG
|
DAIKIN | Cassette | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.49 | 3.90 | 3.90 | -10° | 9.50 | 6.00 | |
|
AZAS71MV1 / ADEA71A
AZAS
|
DAIKIN | Ducted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.44 | 3.81 | 3.62 | -10° | 6.80 | 4.50 | |
|
AR24BXHQASIN / AR24BXHQASIX
RAC
|
SAMSUNG | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.00 | -10° | 7.00 | 4.70 | |
|
RZASG71MV1 / FBA35A9 / FBA35A9
RZASG
|
DAIKIN | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.43 | 3.82 | 3.82 | -10° | 6.80 | 4.50 | |
|
RZASG100MV1 / FBA50A9 / FBA50A9
RZASG
|
DAIKIN | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.38 | 3.80 | 3.80 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FBA50A9 / FBA50A9
RZASG
|
DAIKIN | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.38 | 3.80 | 3.80 | -10° | 9.50 | 6.00 | |
|
RXC71E / FTXC71E
RXC
|
DAIKIN | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.30 | 3.80 | 3.25 | -14° | 7.00 | 6.40 | |
|
ARXC71E / ATXC71E
ARXC
|
DAIKIN | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.30 | 3.80 | 3.21 | -14° | 7.00 | 6.40 | |
|
AZAS71MV1 / FBA71A9
AZAS
|
DAIKIN | Ducted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.57 | 3.81 | 3.73 | -10° | 6.80 | 4.50 | |
|
ARXM71R / FAA71B
ARXM
|
DAIKIN | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.77 | 3.81 | 3.19 | -15° | 6.80 | 4.50 | |
|
ARXM71A / FAA71B
ARXM
|
DAIKIN | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.77 | 3.81 | 3.19 | -15° | 6.80 | 4.50 | |
|
RXM50A8 / FFA50A9
RXM
|
DAIKIN | Cassette | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.86 | 3.36 | -15° | 5.00 | 3.84 | |
|
ARXC71D / ATXC71D
ARXC
|
DAIKIN | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.81 | 3.21 | -14° | 6.96 | 6.35 | |
|
AR09TXHQASIN/AR09TXHQASIX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.90 | 2.60 | |
|
AR09TXHQBWKN/AR09TXHQBWKX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.90 | 2.60 | |
|
AR40H09C1AMN/AR40H09C1AMX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.80 | 2.60 | |
|
AR40H09C1BMN/AR40H09C1BMX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.80 | 2.60 | |
|
AR40F09C0AMN/AR40F09C0AMX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.80 | 2.60 | |
|
AR40F09C0BMN/AR40F09C0BMX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.80 | 2.60 | |
|
AC250KNHPKH / AC250KXAPNH
CAC
|
SAMSUNG | Ducted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.00 | 3.40 | 3.24 | -20° | 25.00 | 18.50 | |
|
RXC71D / FTXC71D
RXC
|
DAIKIN | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.30 | 3.81 | 3.25 | -14° | 6.96 | 6.35 | |
|
5MWXM68A9 / FBA35A9 / FBA35A9
5MWXM
|
DAIKIN | Ducted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.80 | 3.29 | -15° | 6.80 | 3.60 | |
|
RXM50A9 / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.92 | 3.86 | 3.35 | -10° | 5.00 | 4.35 | |
|
AJ100TXJ5KH / AJ050TNAPKH / AJ050TNAPKH
FJM
|
SAMSUNG | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.51 | 3.83 | 3.63 | -10° | 8.56 | 7.70 | |
|
AJ100TXJ5KG / AR60F18C1AW / AR60F18C1AW
FJM
|
SAMSUNG | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.58 | 3.83 | 3.63 | -10° | 8.56 | 7.70 | |
|
RXM60R / FDXM60F9
RXM
|
DAIKIN | Ducted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.56 | 3.80 | 3.21 | -15° | 6.00 | 4.60 | |
|
AZAS71MV1 / FCAG71B
AZAS
|
DAIKIN | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.87 | 4.00 | 3.71 | -10° | 6.80 | 4.50 | |
|
RZASG125MV1 / FUA125A
RZASG
|
DAIKIN | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.49 | 3.84 | 4.00 | 12.10 | 6.00 | ||
|
RZASG125MY1 / FUA125A
RZASG
|
DAIKIN | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.49 | 3.84 | 4.00 | 12.10 | 6.00 | ||
|
RZASG125MV1 / FVA125A
RZASG
|
DAIKIN | Floor standing | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.52 | 3.64 | 3.71 | 12.10 | 6.00 | ||
|
RZASG125MY1 / FVA125A
RZASG
|
DAIKIN | Floor standing | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.52 | 3.64 | 3.71 | 12.10 | 6.00 | ||
|
ARXF71A / ATXF71A
ARXF
|
DAIKIN | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.12 | 3.81 | 3.12 | -15° | 7.10 | 6.20 | |
|
ARXF71A9 / ATXF71A
ARXF
|
DAIKIN | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.12 | 3.81 | 3.12 | -15° | 7.10 | 6.20 | |
|
ARXF71A9 / ATXF71F
ARXF
|
DAIKIN | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.12 | 3.81 | 3.12 | -15° | 7.10 | 6.20 |