Filters · 3 active
Manufacturer:
DAIKIN
GENERAL
AIRCLASS
(4)
AIRWELL
(81)
ATLANTIC
(36)
AUX
(70)
BOSCH
(121)
BRYANT
(6)
Buderus
(34)
CARRIER
(127)
CIAT
(33)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
EQUATION
(5)
FUJI ELECTRIC
(118)
FUJITSU
(271)
Fujitsu Atlantic
(137)
GREE
(119)
GSS
(4)
HAIER
(360)
HEC
(5)
HEIWA
(7)
HISENSE
(314)
HITACHI
(127)
IVT
(10)
Inventor
(116)
KAYSUN
(46)
LG
(254)
MIDEA
(695)
MITSUBISHI ELECTRIC
(432)
Mitsubishi Heavy Industries
(196)
NORD
(52)
Nobu
(8)
PANASONIC
(243)
RIELLO
(35)
Rotenso
(0)
SAMSUNG
(167)
THERMOR
(44)
TOSHIBA
(236)
Viessmann
(24)
Vulcano
(14)
WESTPOINT
(22)
YORK
(29)
Mounting:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AZAS71MV1 / FCAG71B
AZAS
|
DAIKIN | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.87 | 4.00 | 3.71 | -10° | 6.80 | 4.50 | |
|
RZAG60B / FFA60A9
RZAG
|
DAIKIN | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 4.04 | 2.90 | -10° | 6.00 | 4.50 | |
|
ARXM71R / FCAG71B
ARXM
|
DAIKIN | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.87 | 4.00 | 3.38 | -15° | 6.80 | 4.50 | |
|
ARXM71A / FCAG71B
ARXM
|
DAIKIN | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.87 | 4.00 | 3.38 | -15° | 6.80 | 4.50 | |
|
RZASG71MV1 / FVA71A
RZASG
|
DAIKIN | Floor standing | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 4.04 | 3.71 | -10° | 6.80 | 4.50 | |
|
AOHG12KATA/AUXG12KVLA
AUXG**K
|
GENERAL | Cassette | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 3.50 | 2.80 | |
|
ARXQ35A / ATXQ35A
ARXQ
|
DAIKIN | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.15 | 4.11 | 3.71 | -10° | 3.50 | 2.40 | |
|
ARXQ25A / ATXQ25A
ARXQ
|
DAIKIN | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.16 | 4.15 | 3.71 | -10° | 2.50 | 2.30 | |
|
AOHG07KPCA/ASHG07KPCA
ASH**L
|
GENERAL | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.97 | -15° | 2.00 | 2.20 | |
|
AOHG07KPCA/ASHG07KPCE
ASH**L
|
GENERAL | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.97 | -15° | 2.00 | 2.20 | |
|
AOHG09KPCA/ASHG09KPCA
ASH**L
|
GENERAL | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.54 | -15° | 2.50 | 2.40 | |
|
AOHG09KPCA/ASHG09KPCE
ASH**L
|
GENERAL | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.54 | -15° | 2.50 | 2.40 | |
|
RXQ35A / FTXQ35A
RXQ
|
DAIKIN | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.21 | 4.12 | 3.71 | -10° | 3.50 | 2.40 | |
|
RXM60R / FFA60A9
RXM
|
DAIKIN | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.76 | 4.04 | 3.41 | -15° | 5.70 | 3.96 | |
|
AOHG24KBTB/AUXG24KVLA
AUH**K
|
GENERAL | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.69 | -15° | 6.80 | 6.00 | |
|
AOHG14KATA/AUXG14KVLA
AUXG**K
|
GENERAL | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.52 | -15° | 4.30 | 3.20 | |
|
RXF60D9 / FTXF60D
RXF
|
DAIKIN | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.15 | 4.06 | 3.93 | -10° | 6.00 | 4.80 | |
|
RXF60D9 / FTXF60F
RXF
|
DAIKIN | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.15 | 4.06 | 3.93 | -10° | 6.00 | 4.80 | |
|
RZAG60A / FFA60A9
RZAG
|
DAIKIN | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.04 | 2.90 | -20° | 6.00 | 4.50 | |
|
AOHG12KPCA/ASHG12KPCE
ASH**L
|
GENERAL | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.33 | -15° | 3.40 | 2.50 | |
|
AOHG09KATA/AUXG09KVLA
AUXG**K
|
GENERAL | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.64 | -15° | 2.50 | 2.30 | |
|
RXQ25A / FTXQ25A
RXQ
|
DAIKIN | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.22 | 4.22 | 3.71 | -10° | 2.50 | 2.30 | |
|
AOHG24KATA/AUXG24KRLB
AUXG**K
|
GENERAL | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.81 | -15° | 6.80 | 5.40 | |
|
ARXF35E / ATXF35E
ARXF
|
DAIKIN | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.72 | -15° | 3.50 | 2.60 | |
|
ARXF25E / ATXF25E
ARXF
|
DAIKIN | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.73 | -15° | 2.50 | 2.40 | |
|
RZAG50B / FFA50A9
RZAG
|
DAIKIN | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.01 | 3.10 | -10° | 5.00 | 4.30 | |
|
ARXM50R / ADEA50A
ARXM
|
DAIKIN | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.65 | 4.00 | 3.74 | -15° | 5.00 | 4.40 | |
|
RZASG100MV1 / FUA100A
RZASG
|
DAIKIN | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 4.01 | 4.92 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FUA100A
RZASG
|
DAIKIN | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 4.01 | 4.92 | -10° | 9.50 | 6.00 | |
|
RZASG100MV / FUA100A
RZASG
|
DAIKIN | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 4.01 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FUA100A
RZASG
|
DAIKIN | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 4.01 | -10° | 9.50 | 6.00 | ||
|
AOHH12KLTA/ASHH12KLTA
ASH**K
|
GENERAL | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.10 | 3.72 | -15° | 3.40 | 2.50 | |
|
AOHH12KLTA/ASHH12KLTBL
ASH**K
|
GENERAL | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.10 | 3.72 | -15° | 3.40 | 2.50 | |
|
ARXM60R / ADEA60A
ARXM
|
DAIKIN | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.74 | 4.00 | 3.63 | -15° | 5.70 | 4.60 | |
|
ARXF60A / ATXF60A
ARXF
|
DAIKIN | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.12 | 4.03 | 3.90 | -15° | 6.00 | 4.80 | |
|
ARXF60A9 / ATXF60A
ARXF
|
DAIKIN | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.12 | 4.03 | 3.90 | -15° | 6.00 | 4.80 | |
|
ARXF60A9 / ATXF60F
ARXF
|
DAIKIN | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.12 | 4.03 | 3.90 | -15° | 6.00 | 4.80 | |
|
ARXF50A / ATXF50A
ARXF
|
DAIKIN | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.18 | 4.03 | 3.71 | -15° | 5.00 | 4.60 | |
|
RXF60D / FTXF60D
RXF
|
DAIKIN | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.15 | 4.06 | 3.93 | -15° | 6.00 | 4.80 | |
|
AOHG30KATA/AUXG30KRLB
AUXG**K
|
GENERAL | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 8.50 | 8.00 | |
|
AOHG36KATA/AUXG36KRLB
AUXG**K
|
GENERAL | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOHG36KQTA/AUXG36KRLB
AUXG**K
|
GENERAL | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
ARXF50F / ATXF50F
ARXF
|
DAIKIN | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.45 | 4.07 | 3.71 | -15° | 5.00 | 3.80 | |
|
RXF50D / FTXF50D
RXF
|
DAIKIN | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.21 | 4.06 | 3.71 | -15° | 5.00 | 4.60 | |
|
AOHH09KLTA/ASHH09KLTA
ASH**K
|
GENERAL | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 3.73 | -15° | 2.50 | 2.30 | |
|
AOHH09KLTA/ASHH09KLTBL
ASH**K
|
GENERAL | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 3.73 | -15° | 2.50 | 2.30 | |
|
ARXF20E / ATXF20E
ARXF
|
DAIKIN | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.16 | 3.75 | -15° | 2.00 | 2.20 | |
|
ARXF20F / ATXF20F
ARXF
|
DAIKIN | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.16 | 3.75 | -15° | 2.00 | 2.20 | |
|
RXM50A9 / FNA50A9
RXM
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 4.09 | 3.33 | -10° | 5.00 | 4.00 | |
|
ARXC60D / ATXC60D
ARXC
|
DAIKIN | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.38 | 4.19 | 3.71 | -14° | 6.21 | 4.10 |