Filters · 2 active
Manufacturer:
DAIKIN
Mitsubishi Heavy Industries
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(70)
BOSCH
(126)
BRYANT
(6)
Buderus
(38)
CARRIER
(149)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(122)
GSS
(4)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(343)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(70)
LG
(351)
MIDEA
(842)
MITSUBISHI ELECTRIC
(625)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
RIELLO
(47)
Rotenso
(8)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(315)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(22)
YORK
(39)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AZAS125MV / ADEA125A
AZAS
|
DAIKIN | Ducted | 2 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.11 | 3.50 | 12.10 | 6.00 | |||
|
AZAS125MV / FCAG125B
AZAS
|
DAIKIN | Cassette | 3 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.62 | 3.80 | 12.10 | 6.00 | |||
|
AZAS125MY / FCAG125B
AZAS
|
DAIKIN | Cassette | 3 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.62 | 3.80 | 12.10 | 6.00 | |||
|
RZASG125MY / FDA125A
RZASG
|
DAIKIN | Ducted | 3 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.03 | 3.58 | 12.10 | 6.00 | |||
|
RZASG125MV / FDA125A
RZASG
|
DAIKIN | Ducted | 3 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.03 | 3.58 | 12.10 | 6.00 | |||
|
AZAS125MV / FBA125A
AZAS
|
DAIKIN | Ducted | 3 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.24 | 3.55 | 12.10 | 6.00 | |||
|
AZAS125MY / FBA125A
AZAS
|
DAIKIN | Ducted | 3 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.24 | 3.55 | 12.10 | 6.00 | |||
|
FDC250VSA/FDU250VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.82 | 3.52 | 3.75 | 24.00 | 14.20 | ||
|
AZAS125MV / FHA125A
AZAS
|
DAIKIN | Ceiling suspended | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.75 | 12.10 | 6.00 | |||
|
AZAS125MY / FHA125A
AZAS
|
DAIKIN | Ceiling suspended | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.75 | 12.10 | 6.00 | |||
|
AZAS125MV1 / FBA125A
AZAS
|
DAIKIN | Ducted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.85 | 3.55 | 4.01 | 12.10 | 6.00 | ||
|
AZAS125MY1 / FBA125A
AZAS
|
DAIKIN | Ducted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.85 | 3.55 | 4.01 | 12.10 | 6.00 | ||
|
FDC250VSA/FDU250VG
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.83 | 3.52 | 3.75 | 24.00 | 14.20 | ||
|
AZAS125MV / FVA125A
AZAS
|
DAIKIN | Floor standing | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.30 | 3.56 | 3.75 | 12.10 | 6.00 | ||
|
AZAS125MY / FVA125A
AZAS
|
DAIKIN | Floor standing | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.30 | 3.56 | 12.10 | 6.00 | |||
|
AZAS125MV1 / FCAG125B
AZAS
|
DAIKIN | Cassette | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.40 | 3.80 | 12.10 | 6.00 | |||
|
AZAS125MY1 / FCAG125B
AZAS
|
DAIKIN | Cassette | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.40 | 3.80 | 12.10 | 6.00 | |||
|
RZASG125MV1 / FDA125A
RZASG
|
DAIKIN | Ducted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.03 | 3.58 | 12.10 | 6.00 | |||
|
RZASG125MY1 / FDA125A
RZASG
|
DAIKIN | Ducted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.03 | 3.58 | 12.10 | 6.00 | |||
|
AZAS71MV1 / FAA71B
AZAS
|
DAIKIN | Wall mounted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.77 | 3.81 | -10° | 6.80 | 4.50 | ||
|
FDC200VSA/FDU200VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.06 | 3.52 | 3.71 | 19.00 | 12.50 | ||
|
FDC200VSA/FDU200VG
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.07 | 3.52 | 3.71 | 19.00 | 12.50 | ||
|
FDC140VNX/FDF140VD
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.80 | 3.57 | 3.41 | 14.00 | 13.00 | ||
|
RZASG125MY1 / FBA125A
RZASG
|
DAIKIN | Ducted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.49 | 3.63 | 4.01 | 12.10 | 6.00 | ||
|
RZASG125MY / FBA125A
RZASG
|
DAIKIN | Ducted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.49 | 3.63 | 12.10 | 6.00 | |||
|
RZASG125MV / FBA125A
RZASG
|
DAIKIN | Ducted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.49 | 3.63 | 12.10 | 6.00 | |||
|
FDC125VNX/FDE125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.56 | 3.72 | 3.71 | 12.50 | 11.40 | ||
|
FDC250VSA-W/FDU250VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.90 | 3.54 | 3.75 | 25.00 | 14.20 | ||
|
FDC125VSX/FDE125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.74 | 3.66 | 3.71 | 12.50 | 14.00 | ||
|
FDC140VSX/FDE140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.56 | 3.62 | 3.41 | 14.00 | 15.50 | ||
|
AZAS100MV1 / FAA100B
AZAS
|
DAIKIN | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.81 | -10° | 9.50 | 6.00 | ||
|
AZAS100MY1 / FAA100B
AZAS
|
DAIKIN | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.81 | -10° | 9.50 | 6.00 | ||
|
RXM50A9 / FFA50A9
RXM
|
DAIKIN | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.98 | 3.90 | 3.49 | -10° | 5.00 | 3.84 | |
|
AZAS100MV1 / FCAG100B
AZAS
|
DAIKIN | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.67 | 3.85 | 3.71 | -10° | 9.50 | 6.00 | |
|
AZAS100MY1 / FCAG100B
AZAS
|
DAIKIN | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.67 | 3.85 | 3.71 | -10° | 9.50 | 6.00 | |
|
RXF71D9 / FTXF71D
RXF
|
DAIKIN | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.15 | 3.81 | 3.15 | -10° | 7.10 | 6.20 | |
|
RXF71D9 / FTXF71F
RXF
|
DAIKIN | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.15 | 3.81 | 3.15 | -10° | 7.10 | 6.20 | |
|
AZAS100MY / FAA100B
AZAS
|
DAIKIN | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.67 | 3.81 | -10° | 9.50 | 6.00 | ||
|
AZAS100MV / FAA100B
AZAS
|
DAIKIN | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.67 | 3.81 | -10° | 9.50 | 6.00 | ||
|
FDC125VNX/FDF125VD
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.98 | 3.61 | 3.61 | 12.50 | 11.40 | ||
|
FDC140VNX/FDE140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.41 | 3.66 | 3.41 | 14.00 | 13.00 | ||
|
RZASG100MV1 / FFA50A9 / FFA50A9
RZASG
|
DAIKIN | Cassette | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.49 | 3.90 | 3.90 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FFA50A9 / FFA50A9
RZASG
|
DAIKIN | Cassette | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.49 | 3.90 | 3.90 | -10° | 9.50 | 6.00 | |
|
RZASG100MV / FFA50A9 / FFA50A9
RZASG
|
DAIKIN | Cassette | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.49 | 3.90 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FFA50A9 / FFA50A9
RZASG
|
DAIKIN | Cassette | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.49 | 3.90 | -10° | 9.50 | 6.00 | ||
|
FDC140VSX/FDF140VD
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.94 | 3.61 | 3.41 | 14.00 | 14.30 | ||
|
AZAS71MV1 / ADEA71A
AZAS
|
DAIKIN | Ducted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.44 | 3.81 | 3.62 | -10° | 6.80 | 4.50 | |
|
RZASG125MV1 / FBA125A
RZASG
|
DAIKIN | Ducted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.49 | 3.63 | 4.01 | 12.10 | 6.00 | ||
|
RZASG71MV1 / FBA35A9 / FBA35A9
RZASG
|
DAIKIN | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.43 | 3.82 | 3.82 | -10° | 6.80 | 4.50 | |
|
RZASG100MV1 / FAA100B
RZASG
|
DAIKIN | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.83 | 3.85 | -10° | 9.50 | 6.00 |