Filters · 2 active
Manufacturer:
DAIKIN
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(38)
AUX
(70)
BOSCH
(126)
BRYANT
(6)
Buderus
(38)
CARRIER
(130)
CIAT
(36)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
EQUATION
(5)
FUJI ELECTRIC
(138)
FUJITSU
(332)
Fujitsu Atlantic
(165)
GENERAL
(210)
GREE
(122)
GSS
(4)
HAIER
(445)
HEC
(5)
HEIWA
(8)
HISENSE
(314)
HITACHI
(147)
IVT
(10)
Inventor
(124)
KAYSUN
(47)
LG
(291)
MIDEA
(728)
MITSUBISHI ELECTRIC
(446)
Mitsubishi Heavy Industries
(201)
NORD
(52)
Nobu
(8)
PANASONIC
(253)
RIELLO
(38)
Rotenso
(0)
SAMSUNG
(187)
THERMOR
(58)
TOSHIBA
(238)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(22)
YORK
(31)
Mounting:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AZAS71MV1 / FAA71B
AZAS
|
DAIKIN | Wall mounted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.77 | 3.81 | -10° | 6.80 | 4.50 | ||
|
RXM50A9 / FFA50A9
RXM
|
DAIKIN | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.98 | 3.90 | 3.49 | -10° | 5.00 | 3.84 | |
|
AZAS100MV1 / FCAG100B
AZAS
|
DAIKIN | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.67 | 3.85 | 3.71 | -10° | 9.50 | 6.00 | |
|
AZAS100MY1 / FCAG100B
AZAS
|
DAIKIN | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.67 | 3.85 | 3.71 | -10° | 9.50 | 6.00 | |
|
AZAS100MY / FAA100B
AZAS
|
DAIKIN | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.67 | 3.81 | -10° | 9.50 | 6.00 | ||
|
AZAS100MV / FAA100B
AZAS
|
DAIKIN | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.67 | 3.81 | -10° | 9.50 | 6.00 | ||
|
RZASG100MV1 / FAA100B
RZASG
|
DAIKIN | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.83 | 3.85 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY1 / FAA100B
RZASG
|
DAIKIN | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.83 | 3.85 | -10° | 9.50 | 6.00 | ||
|
RZASG100MV / FAA100B
RZASG
|
DAIKIN | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.83 | 3.85 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FAA100B
RZASG
|
DAIKIN | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.83 | 3.85 | -10° | 9.50 | 6.00 | ||
|
ARXM71R / FAA71B
ARXM
|
DAIKIN | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.77 | 3.81 | 3.19 | -15° | 6.80 | 4.50 | |
|
ARXM71A / FAA71B
ARXM
|
DAIKIN | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.77 | 3.81 | 3.19 | -15° | 6.80 | 4.50 | |
|
RXM50A8 / FFA50A9
RXM
|
DAIKIN | Cassette | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.86 | 3.36 | -15° | 5.00 | 3.84 | |
|
RXM50A9 / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.92 | 3.86 | 3.35 | -10° | 5.00 | 4.35 | |
|
AZAS71MV1 / FCAG71B
AZAS
|
DAIKIN | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.87 | 4.00 | 3.71 | -10° | 6.80 | 4.50 | |
|
RXM50R / FFA50A9
RXM
|
DAIKIN | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.98 | 3.90 | 3.49 | -15° | 5.00 | 3.84 | |
|
RXM50A / FFA50A9
RXM
|
DAIKIN | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.98 | 3.90 | 3.49 | -15° | 5.00 | 3.84 | |
|
RZASG71MV1 / FAA71B
RZASG
|
DAIKIN | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.41 | 3.90 | -10° | 6.80 | 4.50 | ||
|
RZASG71MV1 / FFA35A9 / FFA35A9
RZASG
|
DAIKIN | Cassette | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.12 | 3.84 | 3.84 | -10° | 6.80 | 4.50 | |
|
AZAS100MY / FHA100A
AZAS
|
DAIKIN | Ceiling suspended | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.87 | -10° | 9.50 | 6.00 | ||
|
AZAS100MV / FHA100A
AZAS
|
DAIKIN | Ceiling suspended | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.87 | -10° | 9.50 | 6.00 | ||
|
AZAS100MV / FCAG100B
AZAS
|
DAIKIN | Cassette | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.12 | 3.85 | -10° | 9.50 | 6.00 | ||
|
AZAS100MY / FCAG100B
AZAS
|
DAIKIN | Cassette | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.12 | 3.85 | -10° | 9.50 | 6.00 | ||
|
AZAS100MV / FBA100A
AZAS
|
DAIKIN | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.67 | 3.81 | -10° | 9.50 | 6.00 | ||
|
AZAS100MY / FBA100A
AZAS
|
DAIKIN | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.67 | 3.81 | -10° | 9.50 | 6.00 | ||
|
ARXM71A / FHA71A9
ARXM
|
DAIKIN | Ceiling suspended | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.87 | 3.80 | 3.60 | -15° | 6.80 | 4.50 | |
|
5MWXM90A9 / FTXM71A / FTXP20N9
5MWXM
|
DAIKIN | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.97 | 3.55 | -15° | 8.00 | 4.50 | |
|
RZAG60B / FDXM60F9
RZAG
|
DAIKIN | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.90 | 3.30 | -10° | 6.00 | 4.50 | |
|
RZAG60B / FNA60A9
RZAG
|
DAIKIN | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.90 | 3.30 | -10° | 6.00 | 4.50 | |
|
RXM50A8 / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.84 | 3.82 | 3.23 | -15° | 5.00 | 4.35 | |
|
RZASG71MV1 / FHA71A9
RZASG
|
DAIKIN | Ceiling suspended | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.95 | 3.90 | 3.75 | -10° | 6.80 | 4.50 | |
|
RZAG60B / FFA60A9
RZAG
|
DAIKIN | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 4.04 | 2.90 | -10° | 6.00 | 4.50 | |
|
RZASG100MV1 / FBA100A
RZASG
|
DAIKIN | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.85 | 4.77 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FBA100A
RZASG
|
DAIKIN | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.85 | 4.77 | -10° | 9.50 | 6.00 | |
|
RZASG100MV / FBA100A
RZASG
|
DAIKIN | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.85 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FBA100A
RZASG
|
DAIKIN | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.85 | -10° | 9.50 | 6.00 | ||
|
RXM50R / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.86 | 3.35 | -15° | 5.00 | 4.35 | |
|
RXM50A / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.86 | 3.35 | -15° | 5.00 | 4.35 | |
|
ARXM71R / FCAG71B
ARXM
|
DAIKIN | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.87 | 4.00 | 3.38 | -15° | 6.80 | 4.50 | |
|
ARXM71A / FCAG71B
ARXM
|
DAIKIN | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.87 | 4.00 | 3.38 | -15° | 6.80 | 4.50 | |
|
RZAG35B / FFA35A9
RZAG
|
DAIKIN | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.80 | 3.71 | -10° | 3.50 | 4.20 | |
|
RZASG100MV1 / FHA50A9 / FHA50A9
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.92 | 3.92 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FHA50A9 / FHA50A9
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.92 | 3.92 | -10° | 9.50 | 6.00 | |
|
RZASG100MY / FHA50A9 / FHA50A9
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.92 | -10° | 9.50 | 6.00 | ||
|
RZASG100MV / FHA50A9 / FHA50A9
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.92 | -10° | 9.50 | 6.00 | ||
|
RZASG100MV1 / FHA100A
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.91 | 4.81 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FHA100A
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.91 | 4.81 | -10° | 9.50 | 6.00 | |
|
RZASG100MY / FHA100A
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.91 | -10° | 9.50 | 6.00 | ||
|
RZASG100MV / FHA100A
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.91 | -10° | 9.50 | 6.00 | ||
|
RXM50A8 / FDXM50F9
RXM
|
DAIKIN | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.89 | 2.99 | -15° | 5.00 | 4.00 |