Filters · 1 active
Manufacturer:
DE DIETRICH
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(145)
BOSCH
(136)
BRYANT
(6)
Buderus
(38)
CARRIER
(159)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(882)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(139)
GSS
(4)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(409)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(74)
LG
(358)
MIDEA
(843)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
PITSOS
(6)
RIELLO
(47)
Rotenso
(8)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(315)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(24)
XTRON
(4)
YORK
(39)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MOSE 35 (7802981) / UMS 35 (7802986)
CLIM'UP MONOSPLIT
|
DE DIETRICH | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.45 | -10° | 3.50 | 2.70 | |
|
MOSE 2 35 (7885145) / UMS 2 35 (7885142)
CLIM'UP SMART
|
DE DIETRICH | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 3.30 | -10° | 3.50 | 2.70 | |
|
MOSCE 3 35 (7906332) / UCEM 35 (7836597)
CLIM'UP CONSOLE
|
DE DIETRICH | Console | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 3.74 | -10° | 3.52 | 2.70 | |
|
MOSE 25 (7802980) / UMS 25 (7802985)
CLIM'UP MONOSPLIT
|
DE DIETRICH | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 2.37 | -10° | 2.70 | 2.30 | |
|
MOSE 2 25 (7910480) / UMS 2 25 (7910477)
CLIM'UP SMART
|
DE DIETRICH | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 3.20 | -10° | 2.70 | 2.30 | |
|
MOSE 70 (7885146) / UMS 70 (7885143)
CLIM'UP SMART
|
DE DIETRICH | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.13 | -10° | 6.50 | 4.60 | |
|
MOSCE 3 50 (7906333) / UCEM 50 (7836598)
CLIM'UP CONSOLE
|
DE DIETRICH | Console | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.31 | -10° | 4.70 | 3.70 | |
|
MOSE 2 50 (7885144) / UMS 2 50 (7910478)
CLIM'UP SMART
|
DE DIETRICH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.11 | -10° | 5.30 | 3.90 | |
|
MUSE-50-2 (7802989) / UMS 25 (7802985) / UMS 25 (7802985)
CLIM'UP MULTISPLIT
|
DE DIETRICH | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.15 | 4.04 | 3.72 | -10° | 5.40 | 4.40 | |
|
MUSE-40-2 (7722650) / UMS 20 (7802984) / UMS 20 (7802984)
CLIM'UP MULTISPLIT
|
DE DIETRICH | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.18 | 4.13 | 3.91 | -10° | 4.10 | 3.70 | |
|
MUSE 40-2 (7722650) / UMS 2 20 (7910476) x 2
CLIM'UP MULTI
|
DE DIETRICH | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
MOSE 70 (7802983) / UMS 70 (7802988)
CLIM'UP MONOSPLIT
|
DE DIETRICH | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.53 | 4.09 | 3.27 | -10° | 7.20 | 5.70 | |
|
MUSE 2 50-2 (7906285) / UMS 2 25 (7910477) x 2
CLIM'UP MULTI
|
DE DIETRICH | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.40 | 3.90 | -10° | 5.30 | 4.00 | |
|
MOST 35 (7886450) / UMT 35 (7886444)
CLIM'UP EVO
|
DE DIETRICH | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.70 | 3.55 | -10° | 3.50 | 2.80 | |
|
MOST 35 (7886450) / UMT 2 35 (7906263)
CLIM'UP EVO
|
DE DIETRICH | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.70 | 3.55 | -10° | 3.50 | 2.80 | |
|
MOST 25 (7886447) / UMT 25 (7886443)
CLIM'UP EVO
|
DE DIETRICH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.70 | 3.55 | -10° | 2.70 | 2.30 | |
|
MOST 25 (7886447) / UMT 2 25 (7906262)
CLIM'UP EVO
|
DE DIETRICH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.70 | 3.55 | -10° | 2.70 | 2.30 | |
|
MOST 50 (7886451) / UMT 50 (7886445)
CLIM'UP EVO
|
DE DIETRICH | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.20 | -10° | 5.40 | 4.40 | |
|
MOST 50 (7886451) / UMT 2 50 (7906264)
CLIM'UP EVO
|
DE DIETRICH | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.20 | -10° | 5.40 | 4.40 | |
|
MOST 70 (7906267) / UMT 2 70 (7906265)
CLIM'UP EVO
|
DE DIETRICH | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.60 | 3.04 | -10° | 6.10 | 5.40 |