Filters · 3 active
Manufacturer:
GENERAL
GREE
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(5)
AUX
(1)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(4)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(183)
EQUATION
(0)
FUJI ELECTRIC
(43)
FUJITSU
(123)
Fujitsu Atlantic
(61)
GSS
(0)
HAIER
(135)
HEC
(0)
HEIWA
(0)
HISENSE
(5)
HITACHI
(27)
IVT
(0)
Inventor
(11)
KAYSUN
(6)
LG
(58)
MIDEA
(49)
MITSUBISHI ELECTRIC
(167)
Mitsubishi Heavy Industries
(123)
NORD
(0)
Nobu
(0)
PANASONIC
(23)
RIELLO
(1)
Rotenso
(5)
SAMSUNG
(27)
THERMOR
(4)
TOSHIBA
(76)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOHG60LATT/ARHG60LHTA
AOHG**L
|
GENERAL | Ducted | 4 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.50 | 3.50 | 15.00 | 10.80 | ||
|
AOHG45KQTA/ARXG45KMLA
ARXG**K
|
GENERAL | Ducted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.85 | 3.55 | 3.23 | 12.10 | 9.20 | ||
|
AOHG45KATA/ARXG45KMLA
ARXG**K
|
GENERAL | Ducted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.85 | 3.55 | 3.23 | 12.10 | 9.20 | ||
|
AOHG45KQTA/AUXG45KRLB
AUXG**K
|
GENERAL | Cassette | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.40 | 3.80 | 3.58 | 12.10 | 9.20 | ||
|
AOHG45KATA/AUXG45KRLB
AUXG**K
|
GENERAL | Cassette | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.40 | 3.80 | 3.58 | 12.10 | 9.20 | ||
|
AOHG45KATA/ABHG45KRTA
ABY**K
|
GENERAL | Ceiling suspended | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.80 | 3.23 | 12.10 | 9.20 | ||
|
AOHG45KQTA/ABHG45KRTA
ABY**K
|
GENERAL | Ceiling suspended | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.80 | 3.23 | 12.10 | 9.20 | ||
|
AOHG45KATA/ARXH45KMTAP
ARX**K
|
GENERAL | Ducted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.90 | 3.80 | 3.23 | 12.10 | 9.20 | ||
|
AOHG45KQTA/ARXH45KMTAP
ARX**K
|
GENERAL | Ducted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.90 | 3.80 | 3.23 | 12.10 | 9.20 | ||
|
AOHG45LATT/ARHG45LMLA
AOHG**L
|
GENERAL | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.06 | 3.61 | 3.61 | 12.50 | 10.10 | ||
|
AOHG45KBTB/ARXG45KMLA
ARX**K
|
GENERAL | Ducted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.63 | 3.52 | 12.10 | 9.20 | ||
|
AOHG45KRTA/ARXG45KMLA
ARXG**K
|
GENERAL | Ducted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.63 | 3.52 | 12.10 | 9.20 | ||
|
AOHG54KQTA/AUXG54KRLB
AUXG**K
|
GENERAL | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.00 | 3.85 | 3.19 | 13.40 | 9.50 | ||
|
AOHG54KATA/AUXG54KRLB
AUXG**K
|
GENERAL | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.00 | 3.85 | 3.19 | 13.40 | 9.50 | ||
|
AOHG24KATA/AUXG24KVLA
AUXG**K
|
GENERAL | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.80 | 3.61 | -15° | 6.80 | 5.40 | |
|
AOHG14KATA/ARXG14KLLAP
ARXG**K
|
GENERAL | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOHG45LATT
AOH**L Multi
|
GENERAL | Cassette | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.95 | 3.98 | 3.66 | 12.50 | 10.10 | ||
|
AOHG22KATA/ARXG22KMLA
ARXG**K
|
GENERAL | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOHG22KATA/ARXG22KMLB
ARXG**K
|
GENERAL | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOHG54LATT/ABHG54LRTA
AOHG**L
|
GENERAL | Ceiling suspended | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.72 | 3.93 | 3.43 | 14.00 | 10.40 | ||
|
AOHG18KATA/ARXG18KLLAP
ARXG**K
|
GENERAL | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOHG12KATA/ARXG12KLLAP
ARXG**K
|
GENERAL | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOHG09KATA/ARXG09KLLAP
ARXG**K
|
GENERAL | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOHG54KRTA/ABHG54KRTA
ABY**K
|
GENERAL | Ceiling suspended | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.88 | 3.95 | 3.50 | 13.40 | 9.50 | ||
|
AOHG54KBTB/ARXG54KHTAP
ARX**K
|
GENERAL | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 3.85 | 3.98 | 13.40 | 9.50 | ||
|
AOHG54KRTA/ARXG54KHTAP
ARXG**K
|
GENERAL | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 3.85 | 3.98 | 13.40 | 9.50 | ||
|
AOHG54KBTB/ARXG54KHTA
ARX**K
|
GENERAL | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 3.96 | 3.71 | 13.40 | 9.50 | ||
|
AOHG54KBTB/ARXG54KHTB
ARX**K
|
GENERAL | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 3.96 | 3.71 | 13.40 | 9.50 | ||
|
AOHG54KRTA/ARXG54KHTB
ARX**K
|
GENERAL | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 3.96 | 3.71 | 13.40 | 9.50 | ||
|
AOHG54KRTA/ARXG54KHTA
ARX**K
|
GENERAL | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 3.96 | 3.71 | 13.40 | 9.50 | ||
|
AOHG14KBTB/ARXG14KLLAP
ARH**K
|
GENERAL | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOHG45KBTB/ARXG45KHTAP
ARX**K
|
GENERAL | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOHG45KRTA/ARXG45KHTAP
ARXG**K
|
GENERAL | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOHG14KATA/ARXH14KMTAP
ARX**K
|
GENERAL | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOHG24KATA/ARXG24KMLA
ARXG**K
|
GENERAL | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOHG36KATA/ARXG36KMLA
ARXG**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOHG36KQTA/ARXG36KMLA
ARXG**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOHG36KATA/ARXH36KMTAP
ARX**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOHG36KQTA/ARXH36KMTAP
ARXG**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOHG22KATA/ARXH22KMTAP
ARX**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.55 | -15° | 6.00 | 4.40 | |
|
AOHG18KATA/ARXH18KMTAP
ARX**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
AOHG24KATA/ARXH24KMTAP
ARX**K
|
GENERAL | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.81 | -15° | 6.80 | 5.40 | |
|
AOHG54LATT/AUHG54LRLA
AOHG**L
|
GENERAL | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.95 | 4.09 | 3.61 | 14.00 | 10.40 | ||
|
AOHG12KATA/ARXH12KMTAP
ARX**K
|
GENERAL | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOHG45KBTB/ARXG45KHTA
ARX**K
|
GENERAL | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOHG45KBTB/ARXG45KHTB
ARX**K
|
GENERAL | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOHG45KRTA/ARXG45KHTA
ARX**K
|
GENERAL | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOHG45KRTA/ARXG45KHTB
ARX**K
|
GENERAL | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOHG30KATA/ARXG30KMLA
ARXG**K
|
GENERAL | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOHG30KATA/ARXH30KMTAP
ARX**K
|
GENERAL | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.80 | -15° | 8.50 | 8.00 |