Filters · 3 active
Manufacturer:
GENERAL
SAMSUNG
AIRCLASS
(0)
AIRWELL
(11)
ATLANTIC
(12)
AUX
(4)
BOSCH
(17)
BRYANT
(5)
Buderus
(8)
CARRIER
(37)
CIAT
(11)
COLIBRI
(3)
CONFORT AIR
(2)
Candy
(5)
DAIKIN
(81)
EQUATION
(1)
FUJI ELECTRIC
(18)
FUJITSU
(56)
Fujitsu Atlantic
(29)
GREE
(7)
GSS
(0)
HAIER
(234)
HEC
(2)
HEIWA
(1)
HISENSE
(44)
HITACHI
(37)
IVT
(1)
Inventor
(46)
KAYSUN
(19)
LG
(104)
MIDEA
(255)
MITSUBISHI ELECTRIC
(171)
Mitsubishi Heavy Industries
(85)
NORD
(28)
Nobu
(7)
PANASONIC
(33)
RIELLO
(14)
Rotenso
(4)
THERMOR
(12)
TOSHIBA
(96)
Viessmann
(5)
Vulcano
(6)
WESTPOINT
(0)
YORK
(12)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOHG60LATT/ARHG60LHTA
AOHG**L
|
GENERAL | Ducted | 4 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.50 | 3.50 | 15.00 | 10.80 | ||
|
AOHG45KQTA/ARXG45KMLA
ARXG**K
|
GENERAL | Ducted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.85 | 3.55 | 3.23 | 12.10 | 9.20 | ||
|
AOHG45KATA/ARXG45KMLA
ARXG**K
|
GENERAL | Ducted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.85 | 3.55 | 3.23 | 12.10 | 9.20 | ||
|
AR12TXHQASIN/AR12TXHQASIX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.78 | 2.70 | |
|
AR12TXHQBWKN/AR12TXHQBWKX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.78 | 2.70 | |
|
AR40H12C1AMN/AR40H12C1AMX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.60 | 2.70 | |
|
AR40H12C1BMN/AR40H12C1BMX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.60 | 2.70 | |
|
AR40F12C0AMN/AR40F12C0AMX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.60 | 2.70 | |
|
AR40F12C0BMN/AR40F12C0BMX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.60 | 2.70 | |
|
AOHG45KATA/ABHG45KRTA
ABY**K
|
GENERAL | Ceiling suspended | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.80 | 3.23 | 12.10 | 9.20 | ||
|
AOHG45KQTA/ABHG45KRTA
ABY**K
|
GENERAL | Ceiling suspended | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.80 | 3.23 | 12.10 | 9.20 | ||
|
AOHG45KATA/ARXH45KMTAP
ARX**K
|
GENERAL | Ducted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.90 | 3.80 | 3.23 | 12.10 | 9.20 | ||
|
AOHG45KQTA/ARXH45KMTAP
ARX**K
|
GENERAL | Ducted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.90 | 3.80 | 3.23 | 12.10 | 9.20 | ||
|
AR24BXHQASIN / AR24BXHQASIX
RAC
|
SAMSUNG | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.00 | -10° | 7.00 | 4.70 | |
|
AOHG54KQTA/AUXG54KRLB
AUXG**K
|
GENERAL | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.00 | 3.85 | 3.19 | 13.40 | 9.50 | ||
|
AOHG54KATA/AUXG54KRLB
AUXG**K
|
GENERAL | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.00 | 3.85 | 3.19 | 13.40 | 9.50 | ||
|
AC250KNHPKH / AC250KXAPNH
CAC
|
SAMSUNG | Ducted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.00 | 3.40 | 3.24 | -20° | 25.00 | 18.50 | |
|
AR40H24C1AMN/AR40H24C1AMX
RAC
|
SAMSUNG | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.00 | -15° | 7.03 | 4.71 | |
|
AR40F24C0AMN/AR40F24C0AMX
RAC
|
SAMSUNG | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.00 | -15° | 7.03 | 4.71 | |
|
AR40F24C0BMN/AR40F24C0BMX
RAC
|
SAMSUNG | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.00 | -15° | 7.03 | 4.71 | |
|
AC052RXADKG/AC052RNJDKG
CAC
|
SAMSUNG | Floor standing | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 4.00 | 3.01 | -20° | 5.00 | 2.40 | |
|
AC200KNHPKH / AC200KXAPNH
CAC
|
SAMSUNG | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.50 | 3.45 | -20° | 20.00 | 17.50 | |
|
AOHG22KATA/ARXG22KMLA
ARXG**K
|
GENERAL | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOHG22KATA/ARXG22KMLB
ARXG**K
|
GENERAL | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOHG54LATT/ABHG54LRTA
AOHG**L
|
GENERAL | Ceiling suspended | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.72 | 3.93 | 3.43 | 14.00 | 10.40 | ||
|
AOHG18KATA/AUXG18KVLA
AUXG**K
|
GENERAL | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.49 | -15° | 5.20 | 3.80 | |
|
AOHG22KATA/AUXG22KVLA
AUXG**K
|
GENERAL | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.50 | -15° | 6.00 | 4.40 | |
|
AC071RXADKG/AC071RNNDKG
CAC
|
SAMSUNG | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 2.68 | -20° | 6.80 | 4.00 | |
|
AOHG12KATA/ARXG12KLLAP
ARXG**K
|
GENERAL | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOHG54KRTA/ABHG54KRTA
ABY**K
|
GENERAL | Ceiling suspended | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.88 | 3.95 | 3.50 | 13.40 | 9.50 | ||
|
AC052RXADKG/AC052TNXDKG
CAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 3.90 | 3.43 | -20° | 5.00 | 2.40 | |
|
AOHG12KATA/AUXG12KVLA
AUXG**K
|
GENERAL | Cassette | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 3.50 | 2.80 | |
|
AC071RXADKG/AC071RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 2.62 | -20° | 7.10 | 3.50 | |
|
AC100RXADKG/AC100RNTDKG
CAC
|
SAMSUNG | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 2.82 | -20° | 9.50 | 5.60 | |
|
AC100RXADNG/AC100RNTDKG
CAC
|
SAMSUNG | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 2.98 | -20° | 9.50 | 5.60 | |
|
AOHG12KPCA/ASHG12KPCE
ASH**L
|
GENERAL | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.33 | -15° | 3.40 | 2.50 | |
|
AC120RXADKG/AC120RN4DKG
CAC
|
SAMSUNG | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.18 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RN4DKG
CAC
|
SAMSUNG | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.26 | -20° | 12.00 | 6.50 | |
|
AC120RXADKG/AC120RN4PKG
CAC
|
SAMSUNG | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.26 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RN4PKG
CAC
|
SAMSUNG | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.26 | -20° | 12.00 | 6.50 | |
|
AC052RXADKG/AC052RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.90 | 3.13 | -20° | 5.00 | 2.40 | |
|
AC071RXADKG/AC071TNXDKG
CAC
|
SAMSUNG | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.40 | -20° | 7.10 | 3.60 | |
|
AC035RXADKG/AC035RNJDKG
CAC
|
SAMSUNG | Floor standing | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.07 | -20° | 3.50 | 2.00 | |
|
AOHG18KATA/ARXH18KMTAP
ARX**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
AC035RXADKG/AC035RN1DKG
CAC
|
SAMSUNG | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.12 | -20° | 3.50 | 2.00 | |
|
AOHG12KATA/ARXH12KMTAP
ARX**K
|
GENERAL | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.50 | -15° | 3.50 | 2.80 | |
|
AC035RXADKG/AC035BNLDKG
CAC
|
SAMSUNG | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.31 | -20° | 3.50 | 2.00 | |
|
AOHG72LRLA/ARHG72LHTA
AOHG**L
|
GENERAL | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.94 | 3.40 | 19.00 | 15.30 | ||
|
AC071RXADKG/AC071BNLDKG
CAC
|
SAMSUNG | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.36 | -20° | 7.10 | 3.70 | |
|
AC035RXADKG/AC035TNXDKG
CAC
|
SAMSUNG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.10 | 3.31 | -20° | 3.50 | 2.10 |