Filters · 3 active
Manufacturer:
DAIKIN
GREE
AIRCLASS
(2)
AIRWELL
(29)
ATLANTIC
(20)
AUX
(7)
BOSCH
(63)
BRYANT
(4)
Buderus
(18)
CARRIER
(57)
CIAT
(9)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(13)
EQUATION
(2)
FUJI ELECTRIC
(60)
FUJITSU
(123)
Fujitsu Atlantic
(70)
GENERAL
(101)
GSS
(2)
HAIER
(169)
HEC
(4)
HEIWA
(4)
HISENSE
(170)
HITACHI
(34)
IVT
(5)
Inventor
(55)
KAYSUN
(16)
LG
(116)
MIDEA
(316)
MITSUBISHI ELECTRIC
(136)
Mitsubishi Heavy Industries
(49)
NORD
(22)
Nobu
(4)
PANASONIC
(96)
RIELLO
(11)
Rotenso
(0)
SAMSUNG
(96)
THERMOR
(29)
TOSHIBA
(105)
Viessmann
(7)
Vulcano
(4)
WESTPOINT
(14)
YORK
(11)
Mounting:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
GWH12QB-K6DNB2Z
MONOSPLITS
|
GREE | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.20 | 2.70 | |
|
GWH12QB-K6DNC2Z
MONOSPLITS
|
GREE | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.20 | 2.70 | |
|
GWH12QB-K6DNC6Z
MONOSPLITS
|
GREE | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.20 | 2.70 | |
|
GWH12ALBXB-K6DNA4A
MONOSPLITS
|
GREE | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.20 | 2.70 | |
|
GWH12ALBXB-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.20 | 2.70 | |
|
GWH12AGBXB-K6DNA1Z
MONOSPLITS
|
GREE | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.20 | 2.70 | |
|
GWH09QA-K6DNC2Z
MONOSPLITS
|
GREE | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.40 | 4.00 | 3.73 | -10° | 2.50 | 2.50 | |
|
GWH09QA-K6DNC6Z
MONOSPLITS
|
GREE | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.40 | 4.00 | 3.73 | -10° | 2.50 | 2.50 | |
|
GWH07QAXA-K6DNC2Z
MONOSPLITS
|
GREE | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 4.06 | -10° | 2.20 | 2.10 | |
|
GWH07ALAXA-K6DNA4Z
MONOSPLITS
|
GREE | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 4.06 | -10° | 2.20 | 2.10 | |
|
GWH07ALAXA-K6DNA1Z
MONOSPLITS
|
GREE | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 4.06 | -10° | 2.20 | 2.10 | |
|
GWH07AGA-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 4.06 | -10° | 2.20 | 2.10 | |
|
RXM35R9 / FDXM35F9
RXM
|
DAIKIN | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.26 | 3.88 | 3.48 | -15° | 3.40 | 2.90 | |
|
GWH12ALCXB-K6DNA2B
MONOSPLITS
|
GREE | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.90 | -10° | 3.10 | 2.70 | |
|
GWH12AGBXB-K6DNA1F
MONOSPLITS
|
GREE | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.20 | 2.70 | |
|
GWH12AGBXB-K6DNA1I
MONOSPLITS
|
GREE | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.20 | 2.70 | |
|
ARXQ35A / ATXQ35A
ARXQ
|
DAIKIN | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.15 | 4.11 | 3.71 | -10° | 3.50 | 2.40 | |
|
ARXQ25A / ATXQ25A
ARXQ
|
DAIKIN | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.16 | 4.15 | 3.71 | -10° | 2.50 | 2.30 | |
|
GEH12AAXD-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.95 | -10° | 3.52 | 3.20 | |
|
GWH09AGAXB-K6DNA1B
MONOSPLITS
|
GREE | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.10 | 3.83 | -10° | 2.50 | 2.50 | |
|
GWH09ALAXB-K6DNA4B
MONOSPLITS
|
GREE | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.10 | 3.83 | -10° | 2.50 | 2.50 | |
|
GWH09ALAXB-K6DNA1B
MONOSPLITS
|
GREE | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.10 | 3.83 | -10° | 2.50 | 2.50 | |
|
GWH09AWAXB-K6DNA4B
MONOSPLITS
|
GREE | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.10 | 3.83 | -10° | 2.50 | 2.50 | |
|
RZAG35B / FDXM35F9
RZAG
|
DAIKIN | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -10° | 3.50 | 3.50 | |
|
RZAG35B / FNA35A9
RZAG
|
DAIKIN | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -10° | 3.50 | 3.50 | |
|
RXQ35A / FTXQ35A
RXQ
|
DAIKIN | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.21 | 4.12 | 3.71 | -10° | 3.50 | 2.40 | |
|
GWH09AGAXB-K6DNA1C
MONOSPLITS
|
GREE | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 4.00 | -10° | 2.50 | 2.50 | |
|
RXQ25A / FTXQ25A
RXQ
|
DAIKIN | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.22 | 4.22 | 3.71 | -10° | 2.50 | 2.30 | |
|
ARXF35E / ATXF35E
ARXF
|
DAIKIN | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.72 | -15° | 3.50 | 2.60 | |
|
ARXF25E / ATXF25E
ARXF
|
DAIKIN | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.73 | -15° | 2.50 | 2.40 | |
|
GWH12ACC-K6DNA1F
MONOSPLITS
|
GREE | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.10 | 3.99 | -10° | 3.50 | 3.20 | |
|
GWH12AGCXB-K6DNA1Z
MONOSPLITS
|
GREE | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.10 | 3.99 | -10° | 3.50 | 3.20 | |
|
GWH12AUCXB-K6DNA2A
MONOSPLITS
|
GREE | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.10 | 3.89 | -10° | 3.51 | 3.20 | |
|
GWH12AUCXB-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.10 | 3.89 | -10° | 3.50 | 3.20 | |
|
GWH09AGBXB-K6DNA1E
MONOSPLITS
|
GREE | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.20 | 4.08 | -10° | 2.70 | 2.60 | |
|
GWH09ALBXB-K6DNA2D
MONOSPLITS
|
GREE | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.20 | 4.08 | -10° | 2.70 | 2.60 | |
|
ARXF20E / ATXF20E
ARXF
|
DAIKIN | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.16 | 3.75 | -15° | 2.00 | 2.20 | |
|
ARXF20F / ATXF20F
ARXF
|
DAIKIN | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.16 | 3.75 | -15° | 2.00 | 2.20 | |
|
RZAG35A / FDXM35F9
RZAG
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -20° | 3.50 | 3.50 | |
|
RZAG35A / FNA35A9
RZAG
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -20° | 3.50 | 3.50 | |
|
ARXF35F / ATXF35F
ARXF
|
DAIKIN | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.20 | 3.72 | -15° | 3.50 | 2.60 | |
|
ARXF42E / ATXF42E
ARXF
|
DAIKIN | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.45 | 4.25 | 3.71 | -15° | 4.20 | 3.30 | |
|
ARXF42F / ATXF42F
ARXF
|
DAIKIN | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.45 | 4.25 | 3.71 | -15° | 4.20 | 3.30 | |
|
ARXF25F / ATXF25F
ARXF
|
DAIKIN | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.20 | 3.73 | -15° | 2.50 | 2.40 | |
|
ARXM35R9 / ADEA35A
ARXM
|
DAIKIN | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 4.00 | 3.97 | -15° | 3.40 | 2.90 | |
|
RXF35E / FTXF35E
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.72 | -15° | 3.50 | 2.60 | |
|
RXF35F / FTXF35F
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.72 | -15° | 3.50 | 2.60 | |
|
RXF25E / FTXF25E
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.73 | -15° | 2.50 | 2.40 | |
|
RXF25F / FTXF25F
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.73 | -15° | 2.50 | 2.40 | |
|
RXF20E / FTXF20E
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.75 | -15° | 2.00 | 2.20 |