Filters · 2 active
Manufacturer:
BOSCH
HITACHI
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(70)
BRYANT
(6)
Buderus
(38)
CARRIER
(149)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(882)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(122)
GSS
(4)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(343)
IVT
(10)
Inventor
(149)
KAYSUN
(70)
LG
(351)
MIDEA
(842)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
RIELLO
(47)
Rotenso
(8)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(315)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(22)
YORK
(39)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RPFC-6.0UFE1NH/RAS-6.0UFESMH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.33 | 3.55 | 3.42 | -10° | 13.76 | 12.20 | |
|
RPFC-6.5UFE1NH/RAS-6.5UFESMH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.30 | 3.78 | 2.64 | -10° | 16.30 | 11.00 | |
|
RPFC-5.0UFE1NH/RAS-5.0UFESMH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.78 | 3.24 | -10° | 12.10 | 9.50 | |
|
RCI-6.0UFE1NH/RAS-6.0UFESMH1
Primairy R32 series
|
HITACHI | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.64 | 3.81 | 3.51 | -10° | 13.89 | 13.50 | |
|
RCI-6.0UFE1NH/RAS-6.0UFESNH1
Primairy R32 series
|
HITACHI | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.75 | 3.19 | -10° | 14.00 | 13.00 | |
|
CL2000 35 E / CL2000U W 35 E
Climate 2000
|
BOSCH | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
CL2001 35 E / CL2001U W 35 E
Climate 2000
|
BOSCH | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
RCI-6.5UFE1NH/RAS-6.5UFESMH1
Primairy R32 series
|
HITACHI | Cassette | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.87 | 2.89 | -10° | 16.90 | 13.50 | |
|
RPFC-6.0UFE1NH/RAS-6.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling suspended | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.45 | 3.68 | 3.06 | -10° | 14.00 | 12.00 | |
|
RCI-5.0UFE1NH/RAS-5.0UFESNH1
Primairy R32 series
|
HITACHI | Cassette | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.80 | 3.45 | -10° | 12.70 | 9.00 | |
|
CL2000 26 E / CL2000U W 26 E
Climate 2000
|
BOSCH | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
CL2001 26 E / CL2001U W 26 E
Climate 2000
|
BOSCH | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
CL5000M 82/4 E / CL3000iU W 26 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 3.80 | 3.40 | -10° | 8.20 | 6.00 | |
|
CL5000M 53/2 E / CL3000iU W 26 E + CL3000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
RPFC-5.0UFE1NH/RAS-5.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling suspended | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.93 | 3.78 | 3.29 | -10° | 12.70 | 8.70 | |
|
RPFC-4.0UFE1NH/RAS-4.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.87 | 3.82 | 2.88 | -15° | 9.80 | 7.90 | |
|
CL2000 70 E / CL2000U W 70 E
Climate 2000
|
BOSCH | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
CL2001 70 E / CL2001U W 70 E
Climate 2000
|
BOSCH | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
CL5000M 79/3 E / CL3000iU W 26 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.80 | 5.50 | |
|
CL5000M 62/3 E / CL3000iU W 26 E + CL3000iU W 35 E
Climate 5000 M
|
BOSCH | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 6.10 | 5.70 | |
|
CL5000M 53/2 E / CL5000iU W 26 E + CL5000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
CL5000M 53/2 E / CL6001iU W 26 E + CL6001iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
CL5000M 53/2 E / CL5000iM D 26 E + CL5000iM D 26 E
Climate 5000 M
|
BOSCH | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.30 | 4.60 | |
|
RPIL-2.0UNE1NH / RAS-2.0UNESNH1
Primairy R410 series
|
HITACHI | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.40 | -15° | 5.28 | 4.80 | |
|
RCI-5.0UFE1NH/RAS-5.0UFESMH1
Primairy R32 series
|
HITACHI | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.05 | 3.98 | 3.65 | -10° | 12.10 | 9.50 | |
|
CL5001L 26 E / CL5001iU 4CC 26 E
Climate 5001 L
|
BOSCH | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.09 | -10° | 2.60 | 2.00 | |
|
RAC-CJ50WHAE / RAK-CJ50PHAE
RAC-CJ-WHAE airHome 200
|
HITACHI | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.40 | -15° | 4.60 | 4.35 | |
|
RPIH-6.5UFE1NH/RAS-6.5UFESMH1
Primairy R32 series
|
HITACHI | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 3.72 | 2.95 | -10° | 17.10 | 11.00 | |
|
CL5000M 41/2 E / CL5000iM D 21 E + CL5000iM D 21 E
Climate 5000 M
|
BOSCH | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 4.10 | 3.90 | |
|
CL5000M 105/4 / CL3000iU W 53 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.10 | -10° | 10.50 | 8.10 | |
|
CL5000M 41/2 E / CL3000iU W 26 E + CL3000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
CL5000M 41/2 E / CL6001iU W 26 E + CL6001iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 4.18 | -10° | 4.10 | 3.80 | |
|
CL5000L 53 E / CL5000iU CN 50 E
Climate 5000i L
|
BOSCH | Console | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 | |
|
CL5000L 70 E / CL5000iU 4C 70 E
Climate 5000i L
|
BOSCH | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.00 | 6.00 | |
|
RAC-CJ25WHAE / RAK-CJ25PHAE
RAC-CJ-WHAE airHome 200
|
HITACHI | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.71 | -15° | 2.40 | 2.47 | |
|
RAS-4HNC2E / RPK-4.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.83 | 2.87 | -20° | 10.00 | 7.40 | |
|
CL5000M 41/2 E / CL5000iU W 26 E + CL5000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
CL5000L 70 E / CL5000iL CF 70 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
RAS-4HRC2E / RPK-4.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.18 | 3.80 | 2.82 | -20° | 10.00 | 7.40 | |
|
CL5000L 105 E-3 / CL5000iL 4C 105 E
Climate 5000i L
|
BOSCH | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.68 | -10° | 10.50 | 8.00 | |
|
RCI-4.0UFE1NH/RAS-4.0UFESNH1
Primairy R32 series
|
HITACHI | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.92 | 3.20 | -15° | 10.10 | 8.20 | |
|
CL5000L 35 E / CL5000iU CN 35 E
Climate 5000i L
|
BOSCH | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
RPIH-6.0UFE1NH/RAS-6.0UFESMH1
Primairy R32 series
|
HITACHI | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.94 | 3.70 | 3.47 | -10° | 14.19 | 12.40 | |
|
RAC-DJ70WHAE / RAK-DJ70RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.10 | -15° | 7.10 | 5.40 | |
|
RPIH-6.0UFE1NH/RAS-6.0UFESNH1
Primairy R32 series
|
HITACHI | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.94 | 3.70 | 3.40 | -10° | 14.10 | 12.10 | |
|
RPIH-5.0UFE1NH/RAS-5.0UFESNH1
Primairy R32 series
|
HITACHI | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.70 | 3.35 | -10° | 12.50 | 9.00 | |
|
RAS-2HVRC3 / RPK-2.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.77 | 3.88 | 3.91 | -25° | 5.00 | 5.00 | |
|
CL5000L 53 E / CL5000iU 4CC 53 E
Climate 5000i L
|
BOSCH | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
RAC-CJ20WHAE / RAK-CJ20PHAE
RAC-CJ-WHAE airHome 200
|
HITACHI | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.90 | -15° | 2.00 | 1.81 | |
|
RAS-4HVNC2E / RPK-4.0FSR(H)M
UTOPIA PRIME
|