Filters · 3 active
Manufacturer:
EQUATION
HITACHI
AIRCLASS
(0)
AIRWELL
(61)
ATLANTIC
(18)
AUX
(62)
BOSCH
(56)
BRYANT
(6)
Buderus
(16)
CARRIER
(98)
CIAT
(36)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(12)
DAIKIN
(468)
FUJI ELECTRIC
(102)
FUJITSU
(261)
Fujitsu Atlantic
(129)
GENERAL
(134)
GREE
(58)
GSS
(4)
HAIER
(403)
HEC
(3)
HEIWA
(3)
HISENSE
(199)
IVT
(0)
Inventor
(109)
KAYSUN
(60)
LG
(230)
MIDEA
(611)
MITSUBISHI ELECTRIC
(310)
Mitsubishi Heavy Industries
(221)
NORD
(39)
Nobu
(8)
PANASONIC
(133)
RIELLO
(39)
Rotenso
(8)
SAMSUNG
(107)
THERMOR
(35)
TOSHIBA
(175)
Viessmann
(22)
Vulcano
(15)
WESTPOINT
(3)
YORK
(35)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RPFC-6.0UFE1NH/RAS-6.0UFESMH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.33 | 3.55 | 3.42 | -10° | 13.76 | 12.20 | |
|
RPFC-6.5UFE1NH/RAS-6.5UFESMH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.30 | 3.78 | 2.64 | -10° | 16.30 | 11.00 | |
|
RPFC-5.0UFE1NH/RAS-5.0UFESMH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.78 | 3.24 | -10° | 12.10 | 9.50 | |
|
RCI-6.0UFE1NH/RAS-6.0UFESMH1
Primairy R32 series
|
HITACHI | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.64 | 3.81 | 3.51 | -10° | 13.89 | 13.50 | |
|
RCI-6.0UFE1NH/RAS-6.0UFESNH1
Primairy R32 series
|
HITACHI | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.75 | 3.19 | -10° | 14.00 | 13.00 | |
|
RCI-6.5UFE1NH/RAS-6.5UFESMH1
Primairy R32 series
|
HITACHI | Cassette | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.87 | 2.89 | -10° | 16.90 | 13.50 | |
|
RPFC-6.0UFE1NH/RAS-6.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling suspended | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.45 | 3.68 | 3.06 | -10° | 14.00 | 12.00 | |
|
RCI-5.0UFE1NH/RAS-5.0UFESNH1
Primairy R32 series
|
HITACHI | Cassette | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.80 | 3.45 | -10° | 12.70 | 9.00 | |
|
RPFC-5.0UFE1NH/RAS-5.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling suspended | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.93 | 3.78 | 3.29 | -10° | 12.70 | 8.70 | |
|
RPFC-4.0UFE1NH/RAS-4.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.87 | 3.82 | 2.88 | -15° | 9.80 | 7.90 | |
|
RPIL-2.0UNE1NH / RAS-2.0UNESNH1
Primairy R410 series
|
HITACHI | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.40 | -15° | 5.28 | 4.80 | |
|
RCI-5.0UFE1NH/RAS-5.0UFESMH1
Primairy R32 series
|
HITACHI | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.05 | 3.98 | 3.65 | -10° | 12.10 | 9.50 | |
|
RAC-CJ50WHAE / RAK-CJ50PHAE
RAC-CJ-WHAE airHome 200
|
HITACHI | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.40 | -15° | 4.60 | 4.35 | |
|
RPIH-6.5UFE1NH/RAS-6.5UFESMH1
Primairy R32 series
|
HITACHI | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 3.72 | 2.95 | -10° | 17.10 | 11.00 | |
|
Virtus-9K+12K-OUT/Virtus-9K-IN-Multi/Virtus-12K-IN-Multi
Super Match Multi
|
EQUATION | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 5.00 | 4.70 | |
|
RAC-CJ25WHAE / RAK-CJ25PHAE
RAC-CJ-WHAE airHome 200
|
HITACHI | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.71 | -15° | 2.40 | 2.47 | |
|
RAS-4HNC2E / RPK-4.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.83 | 2.87 | -20° | 10.00 | 7.40 | |
|
RAS-4HRC2E / RPK-4.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.18 | 3.80 | 2.82 | -20° | 10.00 | 7.40 | |
|
RCI-4.0UFE1NH/RAS-4.0UFESNH1
Primairy R32 series
|
HITACHI | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.92 | 3.20 | -15° | 10.10 | 8.20 | |
|
RPIH-6.0UFE1NH/RAS-6.0UFESMH1
Primairy R32 series
|
HITACHI | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.94 | 3.70 | 3.47 | -10° | 14.19 | 12.40 | |
|
RAC-DJ70WHAE / RAK-DJ70RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.10 | -15° | 7.10 | 5.40 | |
|
RPIH-6.0UFE1NH/RAS-6.0UFESNH1
Primairy R32 series
|
HITACHI | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.94 | 3.70 | 3.40 | -10° | 14.10 | 12.10 | |
|
RPIH-5.0UFE1NH/RAS-5.0UFESNH1
Primairy R32 series
|
HITACHI | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.70 | 3.35 | -10° | 12.50 | 9.00 | |
|
RAC-CJ20WHAE / RAK-CJ20PHAE
RAC-CJ-WHAE airHome 200
|
HITACHI | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.90 | -15° | 2.00 | 1.81 | |
|
RAS-4HVNC2E / RPK-4.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.17 | 3.83 | 2.87 | -20° | 10.00 | 7.40 | |
|
RPFC-3.0UFE1NH/RAS-3.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 4.01 | 3.55 | -15° | 6.50 | 6.00 | |
|
RAM-G110N5HAE / RAK-XJ50RHAE / RAK-XJ50RHAE
RAM-GNHE
|
HITACHI | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.94 | 3.50 | -15° | 10.00 | 8.70 | |
|
RAM-G110N5HCE / RAK-XJ50RHBE (G)/ RAK-XJ50RHBE(G)
RAM-GNHCE
|
HITACHI | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.94 | 3.50 | -15° | 10.00 | 8.70 | |
|
RAS-4HVRC2E / RPK-4.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.45 | 3.80 | 2.82 | -20° | 10.00 | 7.40 | |
|
RPIH-5.0UFE1NH/RAS-5.0UFESMH1
Primairy R32 series
|
HITACHI | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.28 | 3.70 | 3.29 | -10° | 12.10 | 9.50 | |
|
RAC-CJ35WHAE / RAK-CJ35PHAE
RAC-CJ-WHAE airHome 200
|
HITACHI | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.20 | 3.71 | -15° | 3.20 | 2.80 | |
|
RAS-3HVRC3 / RPK-3.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.11 | 3.90 | 3.19 | -25° | 7.10 | 5.60 | |
|
RPIL-1.5UNE1NH / RAS-1.5UNESNH1
Primairy R410 series
|
HITACHI | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.82 | -15° | 3.52 | 3.52 | |
|
RAS-5HNC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.68 | 3.93 | 3.42 | -20° | 11.90 | 11.93 | |
|
RAC-VJ70NHAE / RAD-VJ70RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.02 | 3.64 | -10° | 7.00 | 5.30 | |
|
RAS-5HNC2E / RPC-5.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.67 | 4.09 | 3.21 | -20° | 11.90 | 11.93 | |
|
RPIH-4.0UFE1NH/RAS-4.0UFESNH1
Primairy R32 series
|
HITACHI | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.92 | 3.00 | -15° | 10.10 | 8.20 | |
|
RAC-DJ60WHAE / RAK-DJ60RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.50 | -15° | 6.00 | 4.80 | |
|
RCI-3.5UFE1NH/RAS-3.5UFESNH1
Primairy R32 series
|
HITACHI | Cassette | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 4.00 | -15° | 8.70 | 7.20 | |
|
RAC-VJ60NHAE / RAI-VJ60RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.21 | 3.75 | -10° | 6.00 | 4.70 | |
|
RAS-4HNC2E / RPC-4.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.51 | 4.17 | 3.53 | -20° | 10.00 | 8.70 | |
|
RAS-5HVNC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 3.93 | 3.42 | -20° | 11.90 | 11.93 | |
|
RAS-4HRC2E / RPC-4.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.70 | 4.12 | 3.47 | -20° | 10.00 | 8.70 | |
|
RPIH-3.5UFE1NH/RAS-3.5UFESNH1
Primairy R32 series
|
HITACHI | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -15° | 8.50 | 6.50 | |
|
RAS-5HVNC2E / RPC-5.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.09 | 3.21 | -20° | 11.90 | 11.93 | |
|
Virtus-24K-IN/Virtus-24K-OUT
Wall mounted - Tundra Plus
|
EQUATION | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.47 | 3.26 | -10° | 7.00 | 5.60 | |
|
RAS-5HRC2E / RPC-5.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.89 | 4.09 | 3.21 | -20° | 11.90 | 11.93 | |
|
RAS-4HVNC2E / RPC-4.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.72 | 4.18 | 3.53 | -20° | 10.00 | 8.70 | |
|
RAC-VJ50NHAE / RAD-VJ50RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.01 | 3.80 | -10° | 5.00 | 4.30 | |
|
RAS-5HVRC2E / RPC-5.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.09 | 4.09 | 3.21 | -20° | 11.90 | 11.93 |