Filters · 3 active
Manufacturer:
DE DIETRICH
IVT
PITSOS
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(145)
BOSCH
(136)
BRYANT
(6)
Buderus
(38)
CARRIER
(159)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(882)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(139)
GSS
(4)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(409)
HITACHI
(171)
Inventor
(149)
KAYSUN
(74)
LG
(358)
MIDEA
(843)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
RIELLO
(47)
Rotenso
(8)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(315)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(24)
XTRON
(4)
YORK
(39)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MOSE 35 (7802981) / UMS 35 (7802986)
CLIM'UP MONOSPLIT
|
DE DIETRICH | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.45 | -10° | 3.50 | 2.70 | |
|
PSO12VW34/PSI12VW34
ΝΕΦΕΛΗ Standard
|
PITSOS | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
PSO12AW32/PSI12AW32
ΙΟΛΗ Premium
|
PITSOS | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
MOSE 2 35 (7885145) / UMS 2 35 (7885142)
CLIM'UP SMART
|
DE DIETRICH | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 3.30 | -10° | 3.50 | 2.70 | |
|
PSO09VW34/PSI09VW34
ΝΕΦΕΛΗ Standard
|
PITSOS | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
PSO09AW32/PSI09AW32
ΙΟΛΗ Premium
|
PITSOS | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
MOSCE 3 35 (7906332) / UCEM 35 (7836597)
CLIM'UP CONSOLE
|
DE DIETRICH | Console | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 3.74 | -10° | 3.52 | 2.70 | |
|
MOSE 25 (7802980) / UMS 25 (7802985)
CLIM'UP MONOSPLIT
|
DE DIETRICH | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 2.37 | -10° | 2.70 | 2.30 | |
|
MOSE 2 25 (7910480) / UMS 2 25 (7910477)
CLIM'UP SMART
|
DE DIETRICH | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 3.20 | -10° | 2.70 | 2.30 | |
|
MOSE 70 (7885146) / UMS 70 (7885143)
CLIM'UP SMART
|
DE DIETRICH | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.13 | -10° | 6.50 | 4.60 | |
|
PSO24AW32/PSI24AW32
ΙΟΛΗ Premium
|
PITSOS | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
MOSCE 3 50 (7906333) / UCEM 50 (7836598)
CLIM'UP CONSOLE
|
DE DIETRICH | Console | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.31 | -10° | 4.70 | 3.70 | |
|
MOSE 2 50 (7885144) / UMS 2 50 (7910478)
CLIM'UP SMART
|
DE DIETRICH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.11 | -10° | 5.30 | 3.90 | |
|
MUSE-50-2 (7802989) / UMS 25 (7802985) / UMS 25 (7802985)
CLIM'UP MULTISPLIT
|
DE DIETRICH | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.15 | 4.04 | 3.72 | -10° | 5.40 | 4.40 | |
|
MUSE-40-2 (7722650) / UMS 20 (7802984) / UMS 20 (7802984)
CLIM'UP MULTISPLIT
|
DE DIETRICH | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.18 | 4.13 | 3.91 | -10° | 4.10 | 3.70 | |
|
MUSE 40-2 (7722650) / UMS 2 20 (7910476) x 2
CLIM'UP MULTI
|
DE DIETRICH | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
PSO18AW32/PSI18AW32
ΙΟΛΗ Premium
|
PITSOS | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
MOSE 70 (7802983) / UMS 70 (7802988)
CLIM'UP MONOSPLIT
|
DE DIETRICH | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.53 | 4.09 | 3.27 | -10° | 7.20 | 5.70 | |
|
MUSE 2 50-2 (7906285) / UMS 2 25 (7910477) x 2
CLIM'UP MULTI
|
DE DIETRICH | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.40 | 3.90 | -10° | 5.30 | 4.00 | |
|
Aero 605-1 O / Aero 605-1 I
Aero 600-1
|
IVT | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.10 | 3.40 | -10° | 5.30 | 4.40 | |
|
Aero 604-1 O / Aero 604-1 I
Aero 600-1
|
IVT | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.40 | |
|
Aero 603-1 O / Aero 603-1 I
Aero 600-1
|
IVT | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.54 | -10° | 2.60 | 2.40 | |
|
Aero 705 O / Aero 705 I
Aero 700
|
IVT | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
Aero 705 O / Aero 705 IB
Aero 700
|
IVT | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
MOST 35 (7886450) / UMT 35 (7886444)
CLIM'UP EVO
|
DE DIETRICH | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.70 | 3.55 | -10° | 3.50 | 2.80 | |
|
MOST 35 (7886450) / UMT 2 35 (7906263)
CLIM'UP EVO
|
DE DIETRICH | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.70 | 3.55 | -10° | 3.50 | 2.80 | |
|
MOST 25 (7886447) / UMT 25 (7886443)
CLIM'UP EVO
|
DE DIETRICH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.70 | 3.55 | -10° | 2.70 | 2.30 | |
|
MOST 25 (7886447) / UMT 2 25 (7906262)
CLIM'UP EVO
|
DE DIETRICH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.70 | 3.55 | -10° | 2.70 | 2.30 | |
|
Aero 607-1 O / Aero 607-1 I
Aero 600-1
|
IVT | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.00 | 5.00 | |
|
MOST 50 (7886451) / UMT 50 (7886445)
CLIM'UP EVO
|
DE DIETRICH | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.20 | -10° | 5.40 | 4.40 | |
|
MOST 50 (7886451) / UMT 2 50 (7906264)
CLIM'UP EVO
|
DE DIETRICH | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.20 | -10° | 5.40 | 4.40 | |
|
MOST 70 (7906267) / UMT 2 70 (7906265)
CLIM'UP EVO
|
DE DIETRICH | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.60 | 3.04 | -10° | 6.10 | 5.40 | |
|
Aero 704 O / Aero 704 I
Aero 700
|
IVT | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 4.50 | -10° | 3.40 | 3.00 | |
|
Aero 704 O / Aero 704 IB
Aero 700
|
IVT | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 4.50 | -10° | 3.40 | 3.00 | |
|
Aero 503 O CN / Aero 503 I CN
Aero 500
|
IVT | Console | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.43 | -10° | 2.60 | 2.80 | |
|
Aero 504 O CN / Aero 504 I CN
Aero 500
|
IVT | Console | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.02 | -10° | 3.60 | 3.60 |