Filters · 4 active
Manufacturer:
BOSCH
Fujitsu Atlantic
Inventor
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(40)
AUX
(70)
BRYANT
(6)
Buderus
(38)
CARRIER
(130)
CIAT
(36)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(560)
EQUATION
(5)
FUJI ELECTRIC
(138)
FUJITSU
(332)
GENERAL
(210)
GREE
(122)
GSS
(4)
HAIER
(449)
HEC
(5)
HEIWA
(8)
HISENSE
(314)
HITACHI
(148)
IVT
(10)
KAYSUN
(47)
LG
(292)
MIDEA
(728)
MITSUBISHI ELECTRIC
(472)
Mitsubishi Heavy Industries
(219)
NORD
(52)
Nobu
(8)
PANASONIC
(254)
RIELLO
(38)
Rotenso
(0)
SAMSUNG
(191)
THERMOR
(58)
TOSHIBA
(252)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(22)
YORK
(31)
Mounting:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U6RSL(2)-18/LN2UVI-09WFI+LN2UVI-09WFI
ODU + Wall Mounted
|
Inventor | Wall mounted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.71 | -10° | 5.30 | 4.34 | |
|
Ν2UVO-09/Ν2UVI-09WFI
Neo
|
Inventor | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.80 | 3.61 | -10° | 2.60 | 2.30 | |
|
N2VOCP-09/Ν2VICP-09WFI
Neo
|
Inventor | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.80 | 3.61 | -10° | 2.60 | 2.30 | |
|
VERO-09/VERI-09WFI
Vero
|
Inventor | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.80 | 3.61 | -10° | 2.60 | 2.30 | |
|
N3VO-09/N3VI-09WFI
Neo
|
Inventor | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.80 | 3.61 | -10° | 2.60 | 2.30 | |
|
CL2000 35 E / CL2000U W 35 E
Climate 2000
|
BOSCH | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
CL2001 35 E / CL2001U W 35 E
Climate 2000
|
BOSCH | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
O3MVO32-12B/O3MVI32-12WiFiRB
Omnia 3 (ECO)
|
Inventor | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
L6VO32-12/L6VI32-12WF
Life PRO
|
Inventor | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
Ν2UVO-12/Ν2UVI-12WFI
Neo
|
Inventor | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.87 | -10° | 3.51 | 2.50 | |
|
N2VOCP-12/Ν2VICP-12WFI
Neo
|
Inventor | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.87 | -10° | 3.51 | 2.50 | |
|
VERO-12/VERI-12WFI
Vero
|
Inventor | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.87 | -10° | 3.51 | 2.50 | |
|
N3VO-12/N3VI-12WFI
Neo
|
Inventor | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.87 | -10° | 3.51 | 2.50 | |
|
PFZUVO-12/PFZUVI-12WIFI
Professional Z
|
Inventor | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.20 | 3.00 | |
|
U6RSL(3)-27/AR5VI-09WiFi+AR5VI-18WiFi
ODU + Wall Mounted
|
Inventor | Wall mounted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.71 | -10° | 7.80 | 5.60 | |
|
AOYG22KATA/ABYG22KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.35 | -15° | 6.00 | 4.40 | |
|
CL2000 26 E / CL2000U W 26 E
Climate 2000
|
BOSCH | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
CL2001 26 E / CL2001U W 26 E
Climate 2000
|
BOSCH | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
O3MVO32-09B/O3MVI32-09WiFiR
Omnia 3 (ECO)
|
Inventor | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
L6VO32-09/L6VI32-09WF
Life PRO
|
Inventor | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
CL5000M 82/4 E / CL3000iU W 26 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 3.80 | 3.40 | -10° | 8.20 | 6.00 | |
|
AOYG24KATA/AUXG24KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.80 | 3.61 | -15° | 6.80 | 5.40 | |
|
AOYG18KATA/ABYG18KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
U7RS-18/V7KI-18WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
AOYG14KATA/ARXG14KLLAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
PFZUVO-09/PFZUVI-09WIFI
Professional Z
|
Inventor | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 3.71 | -10° | 2.70 | 2.60 | |
|
U6RSL(2)-18/AR5VI-09WiFi+AR5VI-09WiFi
ODU + Wall Mounted
|
Inventor | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.30 | 4.30 | |
|
PFZUVO-18/PFZUVI-18WIFI
Professional Z
|
Inventor | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.60 | -10° | 4.80 | 3.60 | |
|
CL5000M 53/2 E / CL3000iU W 26 E + CL3000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
FUTO-24/FUTI-24WFI
Futura AI
|
Inventor | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.13 | -10° | 6.50 | 4.60 | |
|
FUTO-18/FUTI-18WFI
Futura AI
|
Inventor | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.70 | 4.00 | 3.15 | -10° | 5.10 | 3.30 | |
|
CL2000 70 E / CL2000U W 70 E
Climate 2000
|
BOSCH | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
CL2001 70 E / CL2001U W 70 E
Climate 2000
|
BOSCH | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
O3MVO32-24B/O3MVI32-24WiFiR
Omnia 3 (ECO)
|
Inventor | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
L6VO32-24/L6VI32-24WF
Life PRO
|
Inventor | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
AOYG22KATA/ARXG22KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOYG22KATA/ARXG22KMLB
ARXG**K
|
Fujitsu Atlantic | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AR5VO-09/AR5VI-09WFI
Aria (AR5)
|
Inventor | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.90 | 4.00 | 3.80 | -10° | 2.70 | 2.70 | |
|
AOYG18KATA/AUXG18KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.49 | -15° | 5.20 | 3.80 | |
|
CL5000M 79/3 E / CL3000iU W 26 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.80 | 5.50 | |
|
CL5000M 62/3 E / CL3000iU W 26 E + CL3000iU W 35 E
Climate 5000 M
|
BOSCH | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 6.10 | 5.70 | |
|
AOYG22KATA/AUXG22KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOYG18KATA/ARXG18KLLAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOYG36KATA/ABYG36KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/ABYG36KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOYG12KATA/ARXG12KLLAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.50 | -15° | 3.50 | 2.80 | |
|
CL5000M 53/2 E / CL5000iU W 26 E + CL5000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
CL5000M 53/2 E / CL6001iU W 26 E + CL6001iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
CL5000M 53/2 E / CL5000iM D 26 E + CL5000iM D 26 E
Climate 5000 M
|
BOSCH | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.30 | 4.60 | |
|
AOYG09KATA/ARXG09KLLAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 |