Filters · 6 active
Manufacturer:
COLIBRI
Candy
EQUATION
Inventor
SAMSUNG
WESTPOINT
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(145)
BOSCH
(136)
BRYANT
(6)
Buderus
(38)
CARRIER
(159)
CIAT
(44)
CONFORT AIR
(4)
DAIKIN
(882)
DE DIETRICH
(20)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(139)
GSS
(4)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(409)
HITACHI
(171)
IVT
(10)
KAYSUN
(74)
LG
(358)
MIDEA
(843)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
PITSOS
(6)
RIELLO
(47)
Rotenso
(8)
THERMOR
(58)
TOSHIBA
(315)
Viessmann
(24)
Vulcano
(16)
XTRON
(4)
YORK
(39)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC035RXADKG/AC035TNXDKG
CAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.10 | 3.31 | -20° | 3.50 | 2.10 | |
|
AC120RXADKG/AC120RNMDKG
CAC
|
SAMSUNG | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.42 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RNMDKG
CAC
|
SAMSUNG | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.48 | -20° | 12.00 | 6.50 | |
|
AR5VO-18/AR5VI-18WFI
Aria (AR5)
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.70 | -10° | 5.30 | 4.10 | |
|
Ν2UVO-18/Ν2UVI-18WFI
Neo
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
N2VOCP-18/Ν2VICP-18WFI
Neo
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
NPVO-18/NPVI-18WFI
Neo Plus
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
N3VO-18/N3VI-18WFI
Neo
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
VERO-18/VERI-18WFI
Vero
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
WIMO-18222.MH / WIM-18222.MH
WIM 222
|
WESTPOINT | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
AR60F09C1KWN/AR60F09C1KWX
RAC
|
SAMSUNG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
AR70F09C1DBN/AR70F09C1DBX
RAC
|
SAMSUNG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
AC035BXAPKG/AC035BNJPKG
CAC HEE
|
SAMSUNG | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.13 | -25° | 3.50 | 2.00 | |
|
AJ052TXJ3KG / AR70F09C1AW / AR70F09C1AW
FJM
|
SAMSUNG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.03 | 3.63 | -10° | 5.00 | 4.91 | |
|
AR70H09CACBN/AR70H09CACBX
RAC
|
SAMSUNG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
V6FO-60/V6FI-60
Floor Standing
|
Inventor | Floor standing | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.70 | 3.75 | -10° | 14.00 | 10.79 | |
|
AC026RXADKG/AC026TNXDKG
CAC
|
SAMSUNG | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.75 | -20° | 2.60 | 2.10 | |
|
NRO-12/NRI-12WFI
Nura
|
Inventor | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
AC120RXADKG/AC120RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.45 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.47 | -20° | 12.00 | 6.50 | |
|
AC100RXADKG/AC100RNMDKG
CAC
|
SAMSUNG | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.00 | 3.20 | -20° | 10.00 | 5.20 | |
|
AC100RXADNG/AC100RNMDKG
CAC
|
SAMSUNG | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.00 | 3.27 | -20° | 10.00 | 5.20 | |
|
AR50F12C1AHN/AR50F12C1AHX
RAC
|
SAMSUNG | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.76 | -11° | 3.50 | 2.20 | |
|
FUTO-09/FUTI-09WFI
Futura AI
|
Inventor | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.40 | -10° | 2.70 | 2.40 | |
|
IKUO-09/IKUI-09WFI
Ikura
|
Inventor | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.40 | -10° | 2.70 | 2.40 | |
|
AC026RXADKG/AC026RN1DKG
CAC
|
SAMSUNG | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.26 | -20° | 2.60 | 2.00 | |
|
U7RS-18/V7iCRI-18WiFiR
Cassette R32
|
Inventor | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.57 | -10° | 5.30 | 4.20 | |
|
U7RS-24/V7DI-24WiFiR
Ducted R32
|
Inventor | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
NRO-09/NRI-09WFI
Nura
|
Inventor | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 4.00 | -10° | 2.60 | 2.30 | |
|
AC140RXADKG / AC140RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -20° | 13.40 | 8.40 | |
|
AR50F18C1AHN/AR50F18C1AHX
RAC
|
SAMSUNG | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR50F18C1BHN/AR50F18C1BHX
RAC
|
SAMSUNG | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AC100RXADKG/AC100RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.44 | -20° | 10.00 | 5.20 | |
|
AC100RXADNG/AC100RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -20° | 10.00 | 5.20 | |
|
U7RS-36/V7CI-36WiFiR
Cassette R32
|
Inventor | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
NRO-18/NRI-18WFI
Nura
|
Inventor | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 3.90 | -10° | 5.20 | 4.10 | |
|
U7RS-12/V7CRI-12WiFiR
Cassette R32
|
Inventor | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
AC140RXADKG / AC140RN4PKG
CAC
|
SAMSUNG | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.35 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RN4PKG
CAC
|
SAMSUNG | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.41 | -20° | 13.40 | 8.40 | |
|
AR50F09C1AHN/AR50F09C1AHX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
AC026RXADKG/AC026RNJDKG
CAC
|
SAMSUNG | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.30 | -20° | 2.60 | 2.00 | |
|
U7RT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.90 | 3.07 | -10° | 14.00 | 11.20 | |
|
AR50F24C1AHN/AR50F24C1AHX
RAC
|
SAMSUNG | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
AR50F24C1BHN/AR50F24C1BHX
RAC
|
SAMSUNG | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
Virtus-24K-IN/Virtus-24K-OUT
Tundra Plus
|
EQUATION | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.47 | 3.26 | -10° | 7.00 | 5.60 | |
|
AR70F18C1AWN/AR70F18C1AWX
RAC
|
SAMSUNG | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR60F18C1AWN/AR60F18C1AWX
RAC
|
SAMSUNG | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR60F18CAAWN/AR60F18CAAWX
RAC
|
SAMSUNG | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR60F18C1KWN/AR60F18C1KWX
RAC
|
SAMSUNG | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 |