Filters · 3 active
Manufacturer:
Fujitsu Atlantic
Inventor
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(16)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(37)
EQUATION
(0)
FUJI ELECTRIC
(4)
FUJITSU
(12)
GENERAL
(9)
GREE
(4)
GSS
(0)
HAIER
(55)
HEC
(0)
HEIWA
(0)
HISENSE
(6)
HITACHI
(33)
IVT
(0)
KAYSUN
(18)
LG
(9)
MIDEA
(96)
MITSUBISHI ELECTRIC
(45)
Mitsubishi Heavy Industries
(198)
NORD
(0)
Nobu
(0)
PANASONIC
(49)
RIELLO
(6)
Rotenso
(6)
SAMSUNG
(2)
THERMOR
(0)
TOSHIBA
(21)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(6)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOYG60LATT/ARYG60LHTA
AOYG**L
|
Fujitsu Atlantic | Ducted | 4 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.50 | 3.50 | 15.00 | 10.80 | ||
|
AOYG45LATT/ARYG45LMLA
AOYG**L
|
Fujitsu Atlantic | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.06 | 3.61 | 3.61 | 12.50 | 10.10 | ||
|
AOYG45LATT
AOY**L
|
Fujitsu Atlantic | Cassette | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.95 | 3.98 | 3.66 | 12.50 | 10.10 | ||
|
AOYG54LATT/ABYG54LRTA
AOYG**L
|
Fujitsu Atlantic | Ceiling suspended | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.72 | 3.93 | 3.43 | 14.00 | 10.40 | ||
|
U7iRT-60/V7CI-60WiFiR
Cassette R32
|
Inventor | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.19 | -10° | 15.30 | 11.80 | |
|
U7iRT-50/V7CI-50WiFiR
Cassette R32
|
Inventor | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
U7iRT-66/V7iFI-66
Floor Standing
|
Inventor | Floor standing | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
U7RT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.07 | -10° | 14.00 | 11.20 | |
|
U7iRT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
U7iRT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
AOYG45LATT/ABYG45LRTA
AOYG**L
|
Fujitsu Atlantic | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.03 | 3.98 | 3.61 | 12.50 | 10.10 | ||
|
U7RT-50/V7CI-50WiFiR
Cassette R32
|
Inventor | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.00 | |
|
AOYG54LATT/AUYG54LRLA
AOYG**L
|
Fujitsu Atlantic | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.95 | 4.09 | 3.61 | 14.00 | 10.40 | ||
|
U7RT-50/V7DI-50WiFiR
Ducted R32
|
Inventor | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.52 | -10° | 14.00 | 11.50 | |
|
AOYG72LRLA/ARYG72LHTA
AOYG**L
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.94 | 3.40 | 19.00 | 15.30 | ||
|
U7RT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
U7RT-60/V7CI-60WiFiR
Cassette R32
|
Inventor | Cassette | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.22 | -10° | 15.30 | 11.90 | |
|
V6FO-60/V6FI-60
Floor Standing
|
Inventor | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.70 | 3.75 | -10° | 14.00 | 10.79 | |
|
U7RT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.90 | 3.07 | -10° | 14.00 | 11.20 | |
|
AOYG90LRLA/ARYG90LHTA
AOYG**L
|
Fujitsu Atlantic | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
AOYG45LATT/AUYG45LRLA
AOYG**L
|
Fujitsu Atlantic | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.33 | 4.17 | 3.91 | 12.50 | 10.10 | ||
|
U7iRT-50/V7iDI-50WiFiR
Ducted R32
|
Inventor | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
U7RT-60/V7DI-60WiFiR
Ducted R32
|
Inventor | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 15.30 | 12.50 | |
|
U7iRT-60/V7iDI-60WiFiR
Ducted R32
|
Inventor | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
U7iRT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
U7iRT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
U7RT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
V5MF0-66/V5MFI-66Β
Floor Standing
|
Inventor | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.73 | 4.04 | 3.20 | -10° | 14.74 | 11.63 |