Filters · 7 active
Manufacturer:
BOSCH
COLIBRI
Candy
EQUATION
Inventor
LG
Vulcano
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(145)
BRYANT
(6)
Buderus
(38)
CARRIER
(159)
CIAT
(44)
CONFORT AIR
(4)
DAIKIN
(882)
DE DIETRICH
(20)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(139)
GSS
(4)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(409)
HITACHI
(171)
IVT
(10)
KAYSUN
(74)
MIDEA
(843)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
PITSOS
(6)
RIELLO
(47)
Rotenso
(8)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(315)
Viessmann
(24)
WESTPOINT
(24)
XTRON
(4)
YORK
(39)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
WZ24AWN SNU1 / WZ24AWU SUU1
845D
|
LG | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 6.95 | 5.20 | |
|
WZ24AAN SNU1 / WZ24AAU SUU1
845D
|
LG | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 6.95 | 5.20 | |
|
A5UW40GFA1 / ZMNW18GSKC0 / ZMNW24GSKC0
MU
|
LG | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.81 | 3.10 | -15° | 10.00 | 8.00 | |
|
CL5000M 41/2 E / CL5000iU W 26 E + CL5000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
UE-E3CM 41/2 / UI-E3CU M 26 + UI-E3CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
CL5000L 105 E-3 / CL5000iL 4C 105 E
Climate 5000i L
|
BOSCH | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.68 | -10° | 10.50 | 8.00 | |
|
FUTO-12/FUTI-12WFI
Futura AI
|
Inventor | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.10 | 3.40 | -10° | 3.50 | 2.70 | |
|
IKUO-12/IKUI-12WFI
Ikura
|
Inventor | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.10 | 3.40 | -10° | 3.50 | 2.70 | |
|
U7iRT-60/V7CI-60WiFiR
Cassette R32
|
Inventor | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.19 | -10° | 15.30 | 11.80 | |
|
FM40AH.U34
MU
|
LG | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.30 | 12.10 | 8.60 | ||
|
FM41AH.U34
MU
|
LG | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.30 | 12.10 | 8.60 | ||
|
UUD1 U30 / UM42F N20
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD3 U30 / UM42F N20
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD1 U30 / UM42F N21
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD3 U30 / UM42F N21
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
U7iRT-50/V7CI-50WiFiR
Cassette R32
|
Inventor | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
CL5000L 35 E / CL5000iU CN 35 E
Climate 5000i L
|
BOSCH | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
U7RS-12/V7LI-12WiFiR
Console R32
|
Inventor | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
U7iRT-66/V7iFI-66
Floor Standing
|
Inventor | Floor standing | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
U7RT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.07 | -10° | 14.00 | 11.20 | |
|
U7iRT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
CL5000L 53 E / CL5000iU 4CC 53 E
Climate 5000i L
|
BOSCH | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
U7RS-18/V7CRI-18WiFiR
Cassette R32
|
Inventor | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
AR5VO-12/AR5VI-12WFI
Aria (AR5)
|
Inventor | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.50 | -10° | 3.50 | 2.91 | |
|
UUB1 U20 / CL18F N60
UU
|
LG | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.28 | -10° | 5.00 | 4.10 | |
|
O3MVO32-09F/O3MVI32-09WiFiRF
Omnia 3 (ECO)
|
Inventor | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
U7iRT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
UUD1 U30 / UM36F N20
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UM36F N20
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUD1 U30 / UM36F N21
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UM36F N21
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUC1 U40 / CM24F NA0
U4
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.31 | -10° | 6.80 | 5.40 | |
|
U5MRSL32(4)-36/AR5VI-18WiFi+AR5VI-18WiFi
ODU + Wall Mounted
|
Inventor | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.20 | -10° | 10.50 | 8.30 | |
|
UUA1 UL0 / UM12FH N10
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 4.10 | -10° | 3.50 | 2.80 | |
|
UUA1 UL0 / UM12FH NA0
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 4.10 | -10° | 3.50 | 2.80 | |
|
UUC1 U40 / UM36F N20
U4
|
LG | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.57 | -10° | 9.50 | 5.50 | |
|
UUC1 U40 / UM36F N21
U4
|
LG | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.57 | -10° | 9.50 | 5.50 | |
|
U7RT-50/V7CI-50WiFiR
Cassette R32
|
Inventor | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.00 | |
|
CL2000 53 E / CL2000U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
CL2001 53 E / CL2001U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
O3MVO32-18B/O3MVI32-18WiFiR
Omnia 3 (ECO)
|
Inventor | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
L6VO32-18/L6VI32-18WF
Life PRO
|
Inventor | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
UE-EC 53 / UI-ECU M 53
Easy 3 Cool
|
Vulcano | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
U7RS-18/V7KI-18WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
APUW48GT3EA / APNW48GT3EA
UU
|
LG | Floor standing | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.41 | -10° | 13.40 | 11.00 | |
|
W24TI UEU / W24TI NEU
24TI
|
LG | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -15° | 7.00 | 5.20 | |
|
Virtus-12K-IN/Virtus-12K-OUT
Tundra Plus
|
EQUATION | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.00 | 3.81 | -10° | 3.50 | 2.80 | |
|
CL3000i 70 E / CL3000iU W 70 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
CL3000i 70 E / CL3200iU W 70 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
ASO24DW31/ASI24DW31
Series 4
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 |