Filters · 7 active
Manufacturer:
COLIBRI
Candy
HAIER
LG
SAMSUNG
Vulcano
AIRCLASS
(0)
AIRWELL
(12)
ATLANTIC
(0)
AUX
(10)
BOSCH
(15)
BRYANT
(0)
Buderus
(2)
CARRIER
(22)
CIAT
(11)
CONFORT AIR
(0)
DAIKIN
(230)
DE DIETRICH
(0)
EQUATION
(0)
FUJI ELECTRIC
(44)
FUJITSU
(133)
Fujitsu Atlantic
(69)
GENERAL
(69)
GREE
(6)
GSS
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(34)
HITACHI
(41)
IVT
(0)
Inventor
(15)
KAYSUN
(26)
MIDEA
(96)
MITSUBISHI ELECTRIC
(168)
Mitsubishi Heavy Industries
(100)
NORD
(10)
Nobu
(0)
PANASONIC
(42)
PITSOS
(0)
RIELLO
(11)
Rotenso
(3)
THERMOR
(5)
TOSHIBA
(45)
Viessmann
(7)
WESTPOINT
(0)
XTRON
(0)
YORK
(9)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
ADH250H1ERG/1UH250W1ERK
Smart Power - Duct
|
HAIER | Ducted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.97 | 3.50 | 3.43 | 23.50 | 13.00 | ||
|
UU70W U34 / UB70 N94
UU
|
LG | Ducted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.90 | 3.53 | 3.50 | 19.00 | 13.40 | ||
|
UU70W U34 / UB70 N95
UU
|
LG | Ducted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.90 | 3.53 | 3.50 | 19.00 | 13.40 | ||
|
UUA1 UL0 / CL18F N60
UU
|
LG | Ducted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.40 | -10° | 4.70 | 2.70 | |
|
UU85W U74 / UB85 N94
UU
|
LG | Ducted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.80 | 3.51 | 3.25 | 23.00 | 18.50 | ||
|
UU85W U74 / UB85 N95
UU
|
LG | Ducted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.80 | 3.51 | 3.25 | 23.00 | 18.50 | ||
|
UUA1 UL0 / CL12F N50
UU
|
LG | Ducted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.71 | -10° | 3.40 | 2.90 | |
|
AD71S2SS1FA/1U71S2ST1FA
Slim Duct Low Pressure-Monosplit
|
HAIER | Ducted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.41 | 3.80 | 3.34 | -10° | 7.10 | 5.00 | |
|
UUA1 UL0 / CM18F NA0
UU
|
LG | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.80 | 3.50 | -10° | 5.00 | 2.80 | |
|
ADH200H1ERG/1UH200W1ERK
Smart Power - Duct
|
HAIER | Ducted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.82 | 3.43 | 20.50 | 13.00 | ||
|
AC250KNHPKH / AC250KXAPNH
CAC
|
SAMSUNG | Ducted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.00 | 3.40 | 3.24 | -20° | 25.00 | 18.50 | |
|
UUB1 U20 / UM30F N10
UU
|
LG | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.90 | 3.56 | -10° | 7.50 | 4.30 | |
|
UUB1 U20 / UM30F N11
UU
|
LG | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.90 | 3.56 | -10° | 7.50 | 4.30 | |
|
UUB1 U20 / UM30F NA0
UU
|
LG | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.90 | 3.56 | -10° | 7.50 | 4.30 | |
|
AC200KNHPKH / AC200KXAPNH
CAC
|
SAMSUNG | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.50 | 3.45 | -20° | 20.00 | 17.50 | |
|
AD50S2SM3FA/1U50S2SJ2FA-2
Duct Medium Pressure- Monosplit
|
HAIER | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.00 | 4.50 | |
|
AD50S2SS1FA(H)/1U50S2SJ2FA-2
Slim Duct Low Pressure-Monosplit
|
HAIER | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.73 | -10° | 5.00 | 4.30 | |
|
ADH125H1ERG/1U125S2SN1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.70 | 3.42 | 12.10 | 8.00 | ||
|
ADH125H1ERG/1U125S2SN1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.70 | 3.42 | 12.10 | 8.00 | ||
|
UUC1 U40 / UM30F NA0
U4
|
LG | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.71 | -10° | 7.50 | 5.40 | |
|
AD71S2SM3FA/1U71S2SR2FA
Duct Medium Pressure- Monosplit
|
HAIER | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 7.10 | 5.00 | |
|
AD71S2SS1FA/1U71S2SR2FA
Slim Duct Low Pressure-Monosplit
|
HAIER | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.73 | -10° | 7.10 | 5.00 | |
|
AD35S2SM9FA(H)/1U35S2SM1FA-2
Duct Medium Pressure- Monosplit
|
HAIER | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 3.50 | 2.70 | |
|
UUA1 UL0 / CM18F N10
UU
|
LG | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.50 | -10° | 5.00 | 2.80 | |
|
AD25S2SS1FA(H)/1U25S2SM1FA-2
Slim Duct Low Pressure-Monosplit
|
HAIER | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 2.50 | 2.80 | |
|
UUA1 UL0 / CM18F N11
UU
|
LG | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.50 | -10° | 5.00 | 2.80 | |
|
UU250W U80A0 / UB250 N80
UU
|
LG | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 3.83 | 3.79 | 23.00 | 17.60 | ||
|
UU200W U80A0 / UB200 N80
UU
|
LG | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 3.83 | 4.00 | 20.00 | 17.60 | ||
|
AD71S2SS1FA(H)/1U71S2ST1FA
Slim Duct Low Pressure-Monosplit
|
HAIER | Ducted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.41 | 4.00 | 3.34 | -10° | 7.10 | 5.00 | |
|
UUD1 U30 / UM42F N20
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD3 U30 / UM42F N20
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD1 U30 / UM42F N21
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD3 U30 / UM42F N21
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
AD140S2SM3FA/1U140S2SP1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | 13.40 | 11.00 | ||
|
AD140S2SM3FA/1U140S2SN1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.62 | 3.93 | 3.05 | 13.40 | 8.50 | ||
|
AD125S2SM3FA/1U125S2SN2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.72 | 3.93 | 3.23 | 12.30 | 8.00 | ||
|
UUB1 U20 / CL18F N60
UU
|
LG | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.28 | -10° | 5.00 | 4.10 | |
|
AD140S2SM3FA/1U140S2SN1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.64 | 3.96 | 3.13 | 13.40 | 8.50 | ||
|
UUD1 U30 / UM36F N20
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UM36F N20
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUD1 U30 / UM36F N21
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UM36F N21
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
AD140S2SM8FA/1U140S2SN1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.62 | 3.93 | 3.05 | 13.40 | 8.50 | ||
|
AD140S2SM8FA(H)/1U140S2SN1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.62 | 3.93 | 3.05 | 13.40 | 8.50 | ||
|
AD140S2SM9FA(H)/1U140S2SN1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.62 | 3.93 | 3.05 | 13.40 | 8.50 | ||
|
UUC1 U40 / CM24F NA0
U4
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.31 | -10° | 6.80 | 5.40 | |
|
UUA1 UL0 / UM12FH N10
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 4.10 | -10° | 3.50 | 2.80 | |
|
UUA1 UL0 / UM12FH NA0
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 4.10 | -10° | 3.50 | 2.80 | |
|
UUC1 U40 / UM36F N20
U4
|
LG | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.57 | -10° | 9.50 | 5.50 | |
|
UUC1 U40 / UM36F N21
U4
|
LG | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.57 | -10° | 9.50 | 5.50 |